RAPACCHI Stanislas
Research Associate (PhD)
at CNRSResearch associate in charge of acquisition-reconstruction techniques for cardiovascular MRI, and MRI of organs in motion.
Research Associate (PhD)
Detailed Activities
Keywords
- Image Processing
- k-space Acquisition
- Quantitative MRI
- Sodium Homeostatis
- Ultra-high field MRI
- X-Nuclei
- Cardiovascular MRI
- Image reconstruction
- MRI in motion
- Fat metabolism imaging
General Information
Teaching
Grant Supports
Publications :
180164
RAPACCHI
1
harvard-cite-them-right-no-et-al
50
date
desc
year
1298
https://crmbm.univ-amu.fr/wp-content/plugins/zotpress/
%7B%22status%22%3A%22success%22%2C%22updateneeded%22%3Afalse%2C%22instance%22%3Afalse%2C%22meta%22%3A%7B%22request_last%22%3A50%2C%22request_next%22%3A50%2C%22used_cache%22%3Atrue%7D%2C%22data%22%3A%5B%7B%22key%22%3A%224PDXGZ8F%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Baudouard%20et%20al.%22%2C%22parsedDate%22%3A%222025-01-31%22%2C%22numChildren%22%3A0%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BBaudouard%2C%20M.%2C%20Guivier-Curien%2C%20C.%2C%20Rapacchi%2C%20S.%2C%20Jacquier%2C%20A.%20and%20Deplano%2C%20V.%20%282025%29%20%26%23x201C%3BAortic%20displacement%20reconstruction%20to%20build%20a%20patient-specific%20computational%20model%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMultidisciplinary%20Biomechanics%20Journal%26lt%3B%5C%2Fi%26gt%3B%2C%2049th%20congress%20of%20the%20Soci%26%23xE9%3Bt%26%23xE9%3B%20de%20Biom%26%23xE9%3Bcanique%28Cardiovascular%20and%20respiratory%20biomechanics%29.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.46298%5C%2Fmbj.14485%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.46298%5C%2Fmbj.14485%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Aortic%20displacement%20reconstruction%20to%20build%20a%20patient-specific%20computational%20model%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Marc%22%2C%22lastName%22%3A%22Baudouard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Carine%22%2C%22lastName%22%3A%22Guivier-Curien%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alexis%22%2C%22lastName%22%3A%22Jacquier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Valerie%22%2C%22lastName%22%3A%22Deplano%22%7D%5D%2C%22abstractNote%22%3A%22International%20audience%22%2C%22date%22%3A%222025-01-31%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.46298%5C%2Fmbj.14485%22%2C%22ISSN%22%3A%22%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fmbj.episciences.org%5C%2F14485%22%2C%22collections%22%3A%5B%22KFZ6H27M%22%2C%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222025-11-19T13%3A59%3A09Z%22%7D%7D%2C%7B%22key%22%3A%225NQRWUU6%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Licht%20et%20al.%22%2C%22parsedDate%22%3A%222025-01-21%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BLicht%2C%20C.%2C%20Ilicak%2C%20E.%2C%20Boada%2C%20F.E.%2C%20Guye%2C%20M.%2C%20Z%26%23xF6%3Bllner%2C%20F.G.%2C%20Schad%2C%20L.R.%20and%20Rapacchi%2C%20S.%20%282025%29%20%26%23x201C%3BA%20noise-robust%20post-processing%20pipeline%20for%20accelerated%20phase-cycled%2023Na%20Multi-Quantum%20Coherences%20MRI%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BZeitschrift%20Fur%20Medizinische%20Physik%26lt%3B%5C%2Fi%26gt%3B%2C%20pp.%20S0939-3889%2824%2900117-X.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.zemedi.2024.12.004%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.zemedi.2024.12.004%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22A%20noise-robust%20post-processing%20pipeline%20for%20accelerated%20phase-cycled%2023Na%20Multi-Quantum%20Coherences%20MRI%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Christian%22%2C%22lastName%22%3A%22Licht%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Efe%22%2C%22lastName%22%3A%22Ilicak%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fernando%20E.%22%2C%22lastName%22%3A%22Boada%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%20G.%22%2C%22lastName%22%3A%22Z%5Cu00f6llner%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lothar%20R.%22%2C%22lastName%22%3A%22Schad%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20develop%20an%20improved%20post-processing%20pipeline%20for%20noise-robust%20accelerated%20phase-cycled%20Cartesian%20Single%20%28SQ%29%20and%20Triple%20Quantum%20%28TQ%29%20sodium%20%2823Na%29%20Magnetic%20Resonance%20Imaging%20%28MRI%29%20of%20in%20vivo%20human%20brain%20at%207%20T.%5CnTHEORY%20AND%20METHODS%3A%20Our%20pipeline%20aims%20to%20tackle%20the%20challenges%20of%2023Na%20Multi-Quantum%20Coherences%20%28MQC%29%20MRI%20including%20low%20Signal-to-Noise%20Ratio%20%28SNR%29%20and%20time-consuming%20Radiofrequency%20%28RF%29%20phase-cycling.%20Our%20method%20combines%20low-rank%20k-space%20denoising%20for%20SNR%20enhancement%20with%20Dynamic%20Mode%20Decomposition%20%28DMD%29%20to%20robustly%20separate%20SQ%20and%20TQ%20signal%20components.%20This%20separation%20is%20crucial%20for%20computing%20the%20TQ%5C%2FSQ%20ratio%2C%20a%20key%20parameter%20of%2023Na%20MQC%20MRI.%20We%20validated%20our%20pipeline%20in%20silico%2C%20in%20vitro%20and%20in%20vivo%20in%20healthy%20volunteers%2C%20comparing%20it%20with%20conventional%20denoising%20and%20Fourier%20transform%20%28FT%29%20methods.%20Additionally%2C%20we%20assessed%20its%20robustness%20through%20ablation%20experiments%20simulating%20a%20corrupted%20RF%20phase-cycle%20step.%5CnRESULTS%3A%20Our%20denoising%20algorithm%20doubled%20SNR%20compared%20to%20non-denoised%20images%20and%20enhanced%20SNR%20by%20up%20to%2029%25%20compared%20to%20Wavelet%20denoising.%20The%20low-rank%20approach%20produced%20high-quality%20images%20even%20at%20later%20echo%20times%2C%20allowing%20reduced%20signal%20averaging.%20DMD%20effectively%20separated%20the%20SQ%20and%20TQ%20signals%2C%20even%20with%20missing%20RF%20phase%20cycle%20steps%2C%20resulting%20in%20superior%20Structural%20Similarity%20%28SSIM%29%20of%200.89%5Cu00b10.024%20and%20lower%20Root%20Mean%20Squared%20Error%20%28RMSE%29%20of%200.055%5Cu00b10.008%20compared%20to%20conventional%20FT%20methods%20%28SSIM%3D0.71%5Cu00b10.061%2C%20RMSE%3D0.144%5Cu00b10.036%29.%20This%20pipeline%20enabled%20high-quality%208x8x15mm3%20in%20vivo%2023Na%20MQC%20MRI%2C%20with%20a%20reduction%20in%20acquisition%20time%20from%2048%20to%2010%5Cu202fmin%20at%207%20T.%5CnCONCLUSION%3A%20The%20proposed%20pipeline%20improves%20robustness%20in%2023Na%20MQC%20MRI%20by%20exploiting%20low-rank%20properties%20to%20denoise%20signals%20and%20DMD%20to%20effectively%20separate%20SQ%20and%20TQ%20signals.%20This%20approach%20ensures%20high-quality%20MR%20images%20of%20both%20SQ%20and%20TQ%20components%2C%20even%20in%20accelerated%20and%20incomplete%20RF%20phase-cycling%20cases.%22%2C%22date%22%3A%222025-01-21%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.zemedi.2024.12.004%22%2C%22ISSN%22%3A%221876-4436%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222025-11-19T13%3A59%3A11Z%22%7D%7D%2C%7B%22key%22%3A%22XQEY2NIC%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Hoesl%20et%20al.%22%2C%22parsedDate%22%3A%222024-09-02%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BHoesl%2C%20M.A.U.%2C%20Schad%2C%20L.R.%20and%20Rapacchi%2C%20S.%20%282024%29%20%26%23x201C%3BErratum%20to%20%26%23x2018%3BVolumetric%2023Na%20single%20and%20triple-quantum%20imaging%20at%207T%3A%203D-CRISTINA%26%23x2019%3B%20%5BZ%20Med%20Phys%2032%20%282022%29%20199-208%5D%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BZeitschrift%20Fur%20Medizinische%20Physik%26lt%3B%5C%2Fi%26gt%3B%2C%20pp.%20S0939-3889%2824%2900076-X.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.zemedi.2024.07.008%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.zemedi.2024.07.008%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Erratum%20to%20%5C%22Volumetric%2023Na%20single%20and%20triple-quantum%20imaging%20at%207T%3A%203D-CRISTINA%5C%22%20%5BZ%20Med%20Phys%2032%20%282022%29%20199-208%5D%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Michaela%20A.%20U.%22%2C%22lastName%22%3A%22Hoesl%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lothar%20R.%22%2C%22lastName%22%3A%22Schad%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22%22%2C%22date%22%3A%222024-09-02%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.zemedi.2024.07.008%22%2C%22ISSN%22%3A%221876-4436%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222024-09-06T08%3A43%3A15Z%22%7D%7D%2C%7B%22key%22%3A%22RMARCXIW%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Omouri%20et%20al.%22%2C%22parsedDate%22%3A%222024-07-01%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BOmouri%2C%20A.%2C%20Rapacchi%2C%20S.%2C%20Duclos%2C%20J.%2C%20Niddam%2C%20R.%2C%20Bellemare%2C%20M.-E.%20and%20Pirr%26%23xF3%3B%2C%20N.%20%282024%29%20%26%23x201C%3B3D%20Observation%20of%20Pelvic%20Organs%20with%20Dynamic%20MRI%20Segmentation%3A%20A%20Bridge%20Toward%20Patient-Specific%20Models%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BInternational%20Urogynecology%20Journal%26lt%3B%5C%2Fi%26gt%3B%2C%2035%287%29%2C%20pp.%201389%26%23x2013%3B1397.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-ItemURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1007%5C%2Fs00192-024-05817-0%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1007%5C%2Fs00192-024-05817-0%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%223D%20Observation%20of%20Pelvic%20Organs%20with%20Dynamic%20MRI%20Segmentation%3A%20A%20Bridge%20Toward%20Patient-Specific%20Models%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Adel%22%2C%22lastName%22%3A%22Omouri%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Julie%22%2C%22lastName%22%3A%22Duclos%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Rapha%5Cu00ebl%22%2C%22lastName%22%3A%22Niddam%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Marc-Emmanuel%22%2C%22lastName%22%3A%22Bellemare%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Nicolas%22%2C%22lastName%22%3A%22Pirr%5Cu00f3%22%7D%5D%2C%22abstractNote%22%3A%22Female%20pelvic%20organ%20prolapses%20are%20common%2C%20but%20their%20treatment%20is%20challenging.%20Notably%2C%20diagnosis%20and%20understanding%20of%20these%20troubles%20remain%20incomplete.%20Tridimensional%20observations%20of%20displacement%20and%20deformation%20of%20the%20pelvic%20organs%20during%20a%20strain%20could%20support%20a%20better%20understanding%20and%20help%20to%20develop%20comprehensive%20tools%20for%20preoperative%20planning.%22%2C%22date%22%3A%222024-07-01%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1007%5C%2Fs00192-024-05817-0%22%2C%22ISSN%22%3A%221433-3023%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1007%5C%2Fs00192-024-05817-0%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222025-09-12T07%3A59%3A33Z%22%7D%7D%2C%7B%22key%22%3A%22QE5CPJ5M%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Daud%5Cu00e9%20et%20al.%22%2C%22parsedDate%22%3A%222024-06-13%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BDaud%26%23xE9%3B%2C%20P.%2C%20Troalen%2C%20T.%2C%20Mackowiak%2C%20A.L.C.%2C%20Royer%2C%20E.%2C%20Piccini%2C%20D.%2C%20Yerly%2C%20J.%2C%20Pfeuffer%2C%20J.%2C%20Kober%2C%20F.%2C%20Gouny%2C%20S.C.%2C%20Bernard%2C%20M.%2C%20Stuber%2C%20M.%2C%20Bastiaansen%2C%20J.A.M.%20and%20Rapacchi%2C%20S.%20%282024%29%20%26%23x201C%3BTrajectory%20correction%20enables%20free-running%20chemical%20shift%20encoded%20imaging%20for%20accurate%20cardiac%20proton-density%20fat%20fraction%20quantification%20at%203T%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BJournal%20of%20Cardiovascular%20Magnetic%20Resonance%3A%20Official%20Journal%20of%20the%20Society%20for%20Cardiovascular%20Magnetic%20Resonance%26lt%3B%5C%2Fi%26gt%3B%2C%20p.%20101048.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.jocmr.2024.101048%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.jocmr.2024.101048%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Trajectory%20correction%20enables%20free-running%20chemical%20shift%20encoded%20imaging%20for%20accurate%20cardiac%20proton-density%20fat%20fraction%20quantification%20at%203T%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Pierre%22%2C%22lastName%22%3A%22Daud%5Cu00e9%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thomas%22%2C%22lastName%22%3A%22Troalen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ad%5Cu00e8le%20L.%20C.%22%2C%22lastName%22%3A%22Mackowiak%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Emilien%22%2C%22lastName%22%3A%22Royer%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Davide%22%2C%22lastName%22%3A%22Piccini%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22J%5Cu00e9r%5Cu00f4me%22%2C%22lastName%22%3A%22Yerly%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Josef%22%2C%22lastName%22%3A%22Pfeuffer%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%22%2C%22lastName%22%3A%22Kober%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Sylviane%20Confort%22%2C%22lastName%22%3A%22Gouny%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Monique%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Matthias%22%2C%22lastName%22%3A%22Stuber%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jessica%20A.%20M.%22%2C%22lastName%22%3A%22Bastiaansen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%3A%20Metabolic%20diseases%20can%20negatively%20alter%20epicardial%20fat%20accumulation%20and%20composition%2C%20which%20can%20be%20probed%20using%20quantitative%20cardiac%20chemical%20shift%20encoded%28CSE%29%20MRI%20by%20mapping%20proton-density%20fat%20fraction%20%28PDFF%29.%20To%20obtain%20motion-resolved%20high-resolution%20PDFF%20maps%2C%20we%20proposed%20a%20free-running%20cardiac%20CSE-MRI%20framework%20at%203T.%20To%20employ%20faster%20bipolar%20readout%20gradients%2C%20a%20correction%20for%20gradients%20imperfections%20was%20added%20using%20the%20gradient%20impulse%20response%20function%20%28GIRF%29%20and%20evaluated%20on%20intermediate%20images%20and%20PDFF%20quantification.%5CnMETHODS%3A%20Ten%20minutes%20free-running%20cardiac%203D%20radial%20CSE-MRI%20acquisitions%20were%20compared%20in%20vitro%20and%20in%20vivo%20at%203T.%20Monopolar%20and%20bipolar%20readout%20gradients%20schemes%20provided%208%20echoes%20%28TE1%5C%2F%5Cu0394TE%20%3D%201.16%5C%2F1.96ms%29%20and%2013%20echoes%20%28TE1%5C%2F%5Cu0394TE%20%3D%201.12%5C%2F1.07ms%29%2C%20respectively.%20Bipolar-gradients%20free-running%20cardiac%20fat%20and%20water%20images%20and%20PDFF%20maps%20were%20reconstructed%20with%20or%20without%20GIRF-correction.%20PDFF%20values%20were%20evaluated%20in%20silico%2C%20in%20vitro%20on%20a%20fat%5C%2Fwater%20phantom%2C%20and%20in%20vivo%20in%2010%20healthy%20volunteers%20and%20three%20diabetic%20patients.%5CnRESULTS%3A%20In%20monopolar%20mode%2C%20fat-water%20swaps%20were%20demonstrated%20in%20silico%20and%20confirmed%20in%20vitro.%20Using%20bipolar%20readout%20gradients%2C%20PDFF%20quantification%20was%20reliable%20and%20accurate%20with%20GIRF%20correction%20with%20a%20mean%20bias%20of%200.03%25%20in%20silico%20and%200.36%25%20in%20vitro%20while%20it%20suffered%20from%20artifacts%20without%20correction%2C%20leading%20to%20a%20PDFF%20bias%20of%204.9%25%20in%20vitro%20and%20swaps%20in%20vivo.%20Using%20bipolar%20readout%20gradients%2C%20in%20vivo%20PDFF%20of%20epicardial%20adipose%20tissue%20was%20significantly%20lower%20than%20in%20subcutaneous%20fat%20%2880.4%5Cu00b17.1%25%20vs%2092.5%5Cu00b14.3%25%2C%20P%26lt%3B0.0001%29.%5CnCONCLUSION%3A%20Aiming%20for%20an%20accurate%20PDFF%20quantification%2C%20high-resolution%20free-running%20cardiac%20CSE-MRI%20imaging%20proved%20to%20benefit%20from%20bipolar%20echoes%20with%20k-space%20trajectory%20correction%20at%203T.%20This%20free-breathing%20acquisition%20framework%20enables%20to%20investigate%20epicardial%20adipose%20tissue%20PDFF%20in%20metabolic%20diseases.%22%2C%22date%22%3A%222024-06-13%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.jocmr.2024.101048%22%2C%22ISSN%22%3A%221532-429X%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%227JR7EDKF%22%2C%225Z6CVJGB%22%2C%226B37I9FA%22%2C%22ACGLJ26R%22%2C%22XTA6KS7L%22%2C%22BR9D2SS4%22%2C%22K2ZDD9C7%22%5D%2C%22dateModified%22%3A%222025-09-12T07%3A59%3A13Z%22%7D%7D%2C%7B%22key%22%3A%22ERTGNHM7%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Cadour%20et%20al.%22%2C%22parsedDate%22%3A%222024-04-04%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BCadour%2C%20F.%2C%20Cour%2C%20A.%2C%20Senlis%2C%20J.%2C%20Rapacchi%2C%20S.%2C%20Chennoufi%2C%20H.%2C%20Michelin%2C%20P.%2C%20McQuade%2C%20C.%2C%20Demeyere%2C%20M.%20and%20Dacher%2C%20J.-N.%20%282024%29%20%26%23x201C%3BHow%20to%20use%20MRI%20in%20cardiac%20disease%20with%20diastolic%20dysfunction%3F%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BThe%20British%20Journal%20of%20Radiology%26lt%3B%5C%2Fi%26gt%3B%2C%20p.%20tqae071.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1093%5C%2Fbjr%5C%2Ftqae071%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1093%5C%2Fbjr%5C%2Ftqae071%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22How%20to%20use%20MRI%20in%20cardiac%20disease%20with%20diastolic%20dysfunction%3F%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Farah%22%2C%22lastName%22%3A%22Cadour%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Adrien%22%2C%22lastName%22%3A%22Cour%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jules%22%2C%22lastName%22%3A%22Senlis%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Hajer%22%2C%22lastName%22%3A%22Chennoufi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Paul%22%2C%22lastName%22%3A%22Michelin%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Colin%22%2C%22lastName%22%3A%22McQuade%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Matthieu%22%2C%22lastName%22%3A%22Demeyere%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jean-Nicolas%22%2C%22lastName%22%3A%22Dacher%22%7D%5D%2C%22abstractNote%22%3A%22Left%20ventricular%20%28LV%29%20diastolic%20dysfunction%20%28DD%29%20is%20an%20initially%20asymptomatic%20condition%20that%20can%20progress%20to%20heart%20failure%2C%20either%20with%20preserved%20or%20reduced%20ejection%20fraction.%20As%20such%2C%20DD%20is%20a%20growing%20public%20health%20problem.%20Impaired%20relaxation%2C%20the%20first%20stage%20of%20DD%2C%20is%20associated%20with%20altered%20LV%20filling.%20With%20progression%2C%20reducing%20LV%20compliance%20leads%20to%20restrictive%20cardiomyopathy.%20While%20cardiac%20magnetic%20resonance%20%28CMR%29%20imaging%20is%20the%20reference%20for%20LV%20systolic%20function%20assessment%2C%20transthoracic%20echocardiography%20%28TTE%29%20with%20Doppler%20flow%20measurements%20remains%20the%20standard%20for%20diastolic%20function%20assessment.%20Rather%20than%20simply%20replicating%20TTE%20measurements%2C%20CMR%20should%20complement%20and%20further%20advance%20TTE%20findings.%20We%20provide%20herein%20a%20step-by-step%20review%20of%20CMR%20findings%20in%20DD%20as%20well%20as%20imaging%20features%20which%20may%20help%20to%20identify%20the%20underlying%20cause.%22%2C%22date%22%3A%222024-04-04%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1093%5C%2Fbjr%5C%2Ftqae071%22%2C%22ISSN%22%3A%221748-880X%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222025-09-12T07%3A59%3A28Z%22%7D%7D%2C%7B%22key%22%3A%22KM8PBXBP%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Licht%20et%20al.%22%2C%22parsedDate%22%3A%222024%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BLicht%2C%20C.%2C%20Reichert%2C%20S.%2C%20Bydder%2C%20M.%2C%20Zapp%2C%20J.%2C%20Corella%2C%20S.%2C%20Guye%2C%20M.%2C%20Z%26%23xF6%3Bllner%2C%20F.G.%2C%20Schad%2C%20L.R.%20and%20Rapacchi%2C%20S.%20%282024%29%20%26%23x201C%3BLow-rank%20reconstruction%20for%20simultaneous%20double%20half-echo%2023Na%20and%20undersampled%2023Na%20multi-quantum%20coherences%20MRI%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2092%284%29%2C%20pp.%201440%26%23x2013%3B1455.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.30132%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.30132%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Low-rank%20reconstruction%20for%20simultaneous%20double%20half-echo%2023Na%20and%20undersampled%2023Na%20multi-quantum%20coherences%20MRI%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Christian%22%2C%22lastName%22%3A%22Licht%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Simon%22%2C%22lastName%22%3A%22Reichert%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Mark%22%2C%22lastName%22%3A%22Bydder%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jascha%22%2C%22lastName%22%3A%22Zapp%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Shirley%22%2C%22lastName%22%3A%22Corella%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%20G.%22%2C%22lastName%22%3A%22Z%5Cu00f6llner%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lothar%20R.%22%2C%22lastName%22%3A%22Schad%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22Purpose%20To%20develop%20a%20new%20sequence%20to%20simultaneously%20acquire%20Cartesian%20sodium%20%2823Na%29%20MRI%20and%20accelerated%20Cartesian%20single%20%28SQ%29%20and%20triple%20quantum%20%28TQ%29%20sodium%20MRI%20of%20in%20vivo%20human%20brain%20at%207%20T%20by%20leveraging%20two%20dedicated%20low-rank%20reconstruction%20frameworks.%20Theory%20and%20Methods%20The%20Double%20Half-Echo%20technique%20enables%20short%20echo%20time%20Cartesian%2023Na%20MRI%20and%20acquires%20two%20k-space%20halves%2C%20reconstructed%20by%20a%20low-rank%20coupling%20constraint.%20Additionally%2C%20three-dimensional%20%283D%29%2023Na%20Multi-Quantum%20Coherences%20%28MQC%29%20MRI%20requires%20multi-echo%20sampling%20paired%20with%20phase-cycling%2C%20exhibiting%20a%20redundant%20multidimensional%20space.%20Simultaneous%20Autocalibrating%20and%20k-Space%20Estimation%20%28SAKE%29%20were%20used%20to%20reconstruct%20highly%20undersampled%2023Na%20MQC%20MRI.%20Reconstruction%20performance%20was%20assessed%20against%20five-dimensional%20%285D%29%20CS%2C%20evaluating%20structural%20similarity%20index%20%28SSIM%29%2C%20root%20mean%20squared%20error%20%28RMSE%29%2C%20signal-to-noise%20ratio%20%28SNR%29%2C%20and%20quantification%20of%20tissue%20sodium%20concentration%20and%20TQ%5C%2FSQ%20ratio%20in%20silico%2C%20in%20vitro%2C%20and%20in%20vivo.%20Results%20The%20proposed%20sequence%20enabled%20the%20simultaneous%20acquisition%20of%20fully%20sampled%2023Na%20MRI%20while%20leveraging%20prospective%20undersampling%20for%2023Na%20MQC%20MRI.%20SAKE%20improved%20TQ%20image%20reconstruction%20regarding%20SSIM%20by%206%25%20and%20reduced%20RMSE%20by%2035%25%20compared%20to%205D%20CS%20in%20vivo.%20Thanks%20to%20prospective%20undersampling%2C%20the%20spatial%20resolution%20of%2023Na%20MQC%20MRI%20was%20enhanced%20from%208%5Cu00d78%5Cu00d715%5C%5C%208%5C%5Ctimes%208%5C%5Ctimes%2015%20%5C%5C%20mm3%20to%208%5Cu00d78%5Cu00d78%5C%5C%208%5C%5Ctimes%208%5C%5Ctimes%208%20%5C%5C%20mm3%20while%20reducing%20acquisition%20time%20from%202%5Cu00d731%5C%5C%202%5C%5Ctimes%2031%20%5C%5C%20min%20to%202%5Cu00d723%5C%5C%202%5C%5Ctimes%2023%20%5C%5C%20min.%20Conclusion%20The%20proposed%20sequence%2C%20coupled%20with%20low-rank%20reconstructions%2C%20provides%20an%20efficient%20framework%20for%20comprehensive%20whole-brain%20sodium%20MRI%2C%20combining%20TSC%2C%20T2%2A%2C%20and%20TQ%5C%2FSQ%20ratio%20estimations.%20Additionally%2C%20low-rank%20matrix%20completion%20enables%20the%20reconstruction%20of%20highly%20undersampled%2023Na%20MQC%20MRI%2C%20allowing%20for%20accelerated%20acquisition%20or%20enhanced%20spatial%20resolution.%22%2C%22date%22%3A%222024%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.30132%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fonlinelibrary.wiley.com%5C%2Fdoi%5C%2Fabs%5C%2F10.1002%5C%2Fmrm.30132%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222025-09-12T07%3A59%3A38Z%22%7D%7D%2C%7B%22key%22%3A%22Q3KH8WBU%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Licht%20et%20al.%22%2C%22parsedDate%22%3A%222024%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BLicht%2C%20C.%2C%20Reichert%2C%20S.%2C%20Guye%2C%20M.%2C%20Schad%2C%20L.R.%20and%20Rapacchi%2C%20S.%20%282024%29%20%26%23x201C%3BMultidimensional%20compressed%20sensing%20to%20advance%2023Na%20multi-quantum%20coherences%20MRI%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2091%283%29%2C%20pp.%20926%26%23x2013%3B941.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.29902%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.29902%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Multidimensional%20compressed%20sensing%20to%20advance%2023Na%20multi-quantum%20coherences%20MRI%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Christian%22%2C%22lastName%22%3A%22Licht%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Simon%22%2C%22lastName%22%3A%22Reichert%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lothar%20R.%22%2C%22lastName%22%3A%22Schad%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22Purpose%20Sodium%20%2823Na%29%20multi-quantum%20coherences%20%28MQC%29%20MRI%20was%20accelerated%20using%20three-dimensional%20%283D%29%20and%20a%20dedicated%20five-dimensional%20%285D%29%20compressed%20sensing%20%28CS%29%20framework%20for%20simultaneous%20Cartesian%20single%20%28SQ%29%20and%20triple%20quantum%20%28TQ%29%20sodium%20imaging%20of%20in%20vivo%20human%20brain%20at%203.0%20and%207.0%20T.%20Theory%20and%20Methods%203D%2023Na%20MQC%20MRI%20requires%20multi-echo%20paired%20with%20phase-cycling%20and%20exhibits%20thus%20a%20multidimensional%20space.%20A%20joint%20reconstruction%20framework%20to%20exploit%20the%20sparsity%20in%20all%20imaging%20dimensions%20by%20extending%20the%20conventional%203D%20CS%20framework%20to%205D%20was%20developed.%203D%20MQC%20images%20of%20simulated%20brain%2C%20phantom%20and%20healthy%20brain%20volunteers%20obtained%20from%203.0%20T%20and%207.0%20T%20were%20retrospectively%20and%20prospectively%20undersampled.%20Performance%20of%20the%20CS%20models%20were%20analyzed%20by%20means%20of%20structural%20similarity%20index%20%28SSIM%29%2C%20root%20mean%20squared%20error%20%28RMSE%29%2C%20signal-to-noise%20ratio%20%28SNR%29%20and%20signal%20quantification%20of%20tissue%20sodium%20concentration%20and%20TQ%5C%2FSQ%20ratio.%20Results%20It%20was%20shown%20that%20an%20acceleration%20of%20three-fold%2C%20leading%20to%20less%20than%202%5Cu00d710%5C%5C%202%5C%5Ctimes%2010%20%5C%5C%20min%20of%20scan%20time%20with%20a%20resolution%20of%208%5Cu00d78%5Cu00d720%20mm3%5C%5C%208%5C%5Ctimes%208%5C%5Ctimes%2020%5C%5C%3B%5C%5Cmathrmmm%5E3%20%5C%5C%20at%203.0%20T%2C%20are%20possible.%205D%20CS%20improved%20SSIM%20by%203%25%2C%205%25%2C%201%25%20and%20reduced%20RMSE%20by%2050%25%2C%2030%25%2C%208%25%20for%20in%20vivo%20SQ%2C%20TQ%2C%20and%20TQ%5C%2FSQ%20ratio%20maps%2C%20respectively.%20Furthermore%2C%20for%20the%20first%20time%20prospective%20undersampling%20enabled%20unprecedented%20high%20resolution%20from%208%5Cu00d78%5Cu00d720%20mm3%5C%5C%208%5C%5Ctimes%208%5C%5Ctimes%2020%5C%5C%3B%5C%5Cmathrmmm%5E3%20%5C%5C%20to%206%5Cu00d76%5Cu00d710%20mm3%5C%5C%206%5C%5Ctimes%206%5C%5Ctimes%2010%5C%5C%3B%5C%5Cmathrmmm%5E3%20%5C%5C%20MQC%20images%20of%20in%20vivo%20human%20brain%20at%207.0%20T%20without%20extending%20acquisition%20time.%20Conclusion%205D%20CS%20proved%20to%20allow%20up%20to%20three-fold%20acceleration%20retrospectively%20on%203.0%20T%20data.%202-fold%20acceleration%20was%20demonstrated%20prospectively%20at%207.0%20T%20to%20reach%20higher%20spatial%20resolution%20of%2023Na%20MQC%20MRI.%22%2C%22date%22%3A%222024%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.29902%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fonlinelibrary.wiley.com%5C%2Fdoi%5C%2Fabs%5C%2F10.1002%5C%2Fmrm.29902%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222025-09-12T07%3A59%3A37Z%22%7D%7D%2C%7B%22key%22%3A%22YG4NEEFH%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Brui%20et%20al.%22%2C%22parsedDate%22%3A%222024%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BBrui%2C%20E.A.%2C%20Badrieva%2C%20Z.%2C%20de%20Mayenne%2C%20C.-A.%2C%20Rapacchi%2C%20S.%2C%20Troalen%2C%20T.%20and%20Bendahan%2C%20D.%20%282024%29%20%26%23x201C%3BMitigating%20slice%20cross-talk%20in%20multi-slice%20multi-echo%20spin%20echo%20T2%20mapping%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2091%285%29%2C%20pp.%202089%26%23x2013%3B2103.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.29987%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.29987%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Mitigating%20slice%20cross-talk%20in%20multi-slice%20multi-echo%20spin%20echo%20T2%20mapping%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ekaterina%20A.%22%2C%22lastName%22%3A%22Brui%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Zilya%22%2C%22lastName%22%3A%22Badrieva%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Charles-Alexis%22%2C%22lastName%22%3A%22de%20Mayenne%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thomas%22%2C%22lastName%22%3A%22Troalen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22David%22%2C%22lastName%22%3A%22Bendahan%22%7D%5D%2C%22abstractNote%22%3A%22Purpose%20To%20investigate%20whether%20a%20T2%20inter-slice%20variation%20could%20occur%20when%20a%20multi-slice%20multi-echo%20spin%20echo%20%28MESE%29%20sequence%20is%20used%20for%20image%20acquisition%20and%20to%20propose%20an%20enhanced%20method%20for%20reconstructing%20T2%20maps%20that%20can%20effectively%20address%20and%20correct%20these%20variations.%20Methods%20Bloch%20simulations%20were%20performed%20accounting%20for%20the%20direct%20saturation%20effect%20to%20evaluate%20magnetization%20changes%20in%20multi-slice%202D%20MESE%20sequence.%20Experimental%20phantom%20scans%20were%20performed%20to%20validate%20these%20simulations.%20An%20improved%20version%20of%20the%20dictionary-based%20reconstruction%20approach%20was%20proposed%2C%20enabling%20the%20creation%20of%20a%20multi-slice%20dictionary%20of%20echo%20modulation%20curves%20%28EMC%29.%20The%20corresponding%20method%20has%20been%20assayed%20considering%20inter-slice%20T2%20variation%20with%20phantoms%20and%20in%20lower%20leg.%20Results%20Experimental%20and%20numerical%20study%20illustrate%20that%20direct%20saturation%20leads%20to%20a%20bias%20of%20EMCs.%20This%20bias%20during%20the%20T2%20maps%20reconstructions%20using%20original%20single-slice%20EMC-dictionary%20method%20led%20to%20inter-slice%20T2%20variation%20of%202.03%25%20in%20average%20coefficient%20of%20variation%20%28CV%29%20in%20agarose%20phantoms%2C%20and%20up%20to%202.8%25%20in%20vivo%20%28for%20TR%20%3D%202%20s%2C%20slice%20gap%20%3D%200%25%29.%20A%20reduction%20of%20CV%20was%20observed%20when%20increasing%20the%20gap%20up%20to%20100%25%20%280.36%25%20in%20phantoms%2C%20and%20up%20to%201.5%25%20in%20vivo%29%20or%20increasing%20TR%20up%20to%204%20s%20%280.76%25%20in%20phantoms%2C%20and%20up%20to%201.9%25%20in%20vivo%29.%20Matching%20the%20multi-slice%20experimental%20data%20with%20multi-slice%20dictionaries%20provided%20a%20reduced%20CV%20of%200.54%25%20in%20phantoms%20and%20up%20to%202.3%25%20in%20vivo.%20Conclusion%20T2%20values%20quantified%20from%20multi-slice%20MESE%20images%20using%20single-slice%20dictionaries%20are%20biased.%20A%20dedicated%20multi-slice%20EMC%20method%20providing%20the%20appropriate%20dictionaries%20can%20reduce%20the%20inter-slice%20T2%20variation.%22%2C%22date%22%3A%222024%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.29987%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fonlinelibrary.wiley.com%5C%2Fdoi%5C%2Fabs%5C%2F10.1002%5C%2Fmrm.29987%22%2C%22collections%22%3A%5B%226GBQDAVI%22%2C%22NW6SZQBR%22%2C%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222025-09-12T07%3A59%3A36Z%22%7D%7D%2C%7B%22key%22%3A%22TM953QIS%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Bo%5Cu017ei%5Cu0107-Iven%20et%20al.%22%2C%22parsedDate%22%3A%222024%22%2C%22numChildren%22%3A0%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BBo%26%23x17E%3Bi%26%23x107%3B-Iven%2C%20M.%2C%20Rapacchi%2C%20S.%2C%20Tao%2C%20Q.%2C%20Pierce%2C%20I.%2C%20Thornton%2C%20G.%2C%20Nitsche%2C%20C.%2C%20Treibel%2C%20T.A.%2C%20Schad%2C%20L.R.%20and%20Weing%26%23xE4%3Brtner%2C%20S.%20%282024%29%20%26%23x201C%3BImproved%20reproducibility%20for%20myocardial%20ASL%3A%20Impact%20of%20physiological%20and%20acquisition%20parameters%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2091%281%29%2C%20pp.%20118%26%23x2013%3B132.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.29834%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.29834%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Improved%20reproducibility%20for%20myocardial%20ASL%3A%20Impact%20of%20physiological%20and%20acquisition%20parameters%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ma%5Cu0161a%22%2C%22lastName%22%3A%22Bo%5Cu017ei%5Cu0107-Iven%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Qian%22%2C%22lastName%22%3A%22Tao%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Iain%22%2C%22lastName%22%3A%22Pierce%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22George%22%2C%22lastName%22%3A%22Thornton%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Christian%22%2C%22lastName%22%3A%22Nitsche%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thomas%20A.%22%2C%22lastName%22%3A%22Treibel%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lothar%20R.%22%2C%22lastName%22%3A%22Schad%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Sebastian%22%2C%22lastName%22%3A%22Weing%5Cu00e4rtner%22%7D%5D%2C%22abstractNote%22%3A%22Purpose%20To%20investigate%20and%20mitigate%20the%20influence%20of%20physiological%20and%20acquisition-related%20parameters%20on%20myocardial%20blood%20flow%20%28MBF%29%20measurements%20obtained%20with%20myocardial%20Arterial%20Spin%20Labeling%20%28myoASL%29.%20Methods%20A%20Flow-sensitive%20Alternating%20Inversion%20Recovery%20%28FAIR%29%20myoASL%20sequence%20with%20bSSFP%20and%20spoiled%20GRE%20%28spGRE%29%20readout%20is%20investigated%20for%20MBF%20quantification.%20Bloch-equation%20simulations%20and%20phantom%20experiments%20were%20performed%20to%20evaluate%20how%20variations%20in%20acquisition%20flip%20angle%20%28FA%29%2C%20acquisition%20matrix%20size%20%28AMS%29%2C%20heart%20rate%20%28HR%29%20and%20blood%20T1%5C%5C%20%5C%5CmathrmT_1%20%5C%5C%20relaxation%20time%20%28T1%2CB%5C%5C%20%5C%5CmathrmT_1%2CB%20%5C%5C%29%20affect%20quantification%20of%20myoASL-MBF.%20In%20vivo%20myoASL-images%20were%20acquired%20in%20nine%20healthy%20subjects.%20A%20corrected%20MBF%20quantification%20approach%20was%20proposed%20based%20on%20subject-specific%20T1%2CB%5C%5C%20%5C%5CmathrmT_1%2CB%20%5C%5C%20values%20and%2C%20for%20spGRE%20imaging%2C%20subtracting%20an%20additional%20saturation-prepared%20baseline%20from%20the%20original%20baseline%20signal.%20Results%20Simulated%20and%20phantom%20experiments%20showed%20a%20strong%20dependence%20on%20AMS%20and%20FA%20%28R2%5C%5C%20R%5E2%20%5C%5C%26gt%3B0.73%29%2C%20which%20was%20eliminated%20in%20simulations%20and%20alleviated%20in%20phantom%20experiments%20using%20the%20proposed%20saturation-baseline%20correction%20in%20spGRE.%20Only%20a%20very%20mild%20HR%20dependence%20%28R2%5C%5C%20R%5E2%20%5C%5C%26gt%3B0.59%29%20was%20observed%20which%20was%20reduced%20when%20calculating%20MBF%20with%20individual%20T1%2CB%5C%5C%20%5C%5CmathrmT_1%2CB%20%5C%5C.%20For%20corrected%20spGRE%2C%20in%20vivo%20mean%20global%20spGRE-MBF%20ranged%20from%200.54%20to%202.59%20mL%5C%2Fg%5C%2Fmin%20and%20was%20in%20agreement%20with%20previously%20reported%20values.%20Compared%20to%20uncorrected%20spGRE%2C%20the%20intra-subject%20variability%20within%20a%20measurement%20%280.60%20mL%5C%2Fg%5C%2Fmin%29%2C%20between%20measurements%20%280.45%20mL%5C%2Fg%5C%2Fmin%29%2C%20as%20well%20as%20the%20inter-subject%20variability%20%281.29%20mL%5C%2Fg%5C%2Fmin%29%20were%20improved%20by%20up%20to%2040%25%20and%20were%20comparable%20with%20conventional%20bSSFP.%20Conclusion%20Our%20results%20show%20that%20physiological%20and%20acquisition-related%20factors%20can%20lead%20to%20spurious%20changes%20in%20myoASL-MBF%20if%20not%20accounted%20for.%20Using%20individual%20T1%2CB%5C%5C%20%5C%5CmathrmT_1%2CB%20%5C%5C%20and%20a%20saturation-baseline%20can%20reduce%20these%20variations%20in%20spGRE%20and%20improve%20reproducibility%20of%20FAIR-myoASL%20against%20acquisition%20parameters.%22%2C%22date%22%3A%222024%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.29834%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fonlinelibrary.wiley.com%5C%2Fdoi%5C%2Fabs%5C%2F10.1002%5C%2Fmrm.29834%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222025-09-12T07%3A59%3A29Z%22%7D%7D%2C%7B%22key%22%3A%22FMDIVD5H%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Cadour%20et%20al.%22%2C%22parsedDate%22%3A%222024%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BCadour%2C%20F.%2C%20Sourdon%2C%20J.%20and%20Rapacchi%2C%20S.%20%282024%29%20%26%23x201C%3BEditorial%20for%20%26%23x2018%3BBiventricular%20Dysfunction%20and%20Ventricular%20Interdependence%20in%20Patients%20With%20Pulmonary%20Hypertension%3A%20A%203.0-T%20Cardiac%20MRI%20Feature%20Tracking%20Study%2C%26%23x2019%3B%26%23x201D%3B%20%26lt%3Bi%26gt%3BJournal%20of%20Magnetic%20Resonance%20Imaging%26lt%3B%5C%2Fi%26gt%3B%2C%2060%281%29%2C%20pp.%20363%26%23x2013%3B364.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fjmri.29092%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fjmri.29092%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Editorial%20for%20%5Cu201cBiventricular%20Dysfunction%20and%20Ventricular%20Interdependence%20in%20Patients%20With%20Pulmonary%20Hypertension%3A%20A%203.0-T%20Cardiac%20MRI%20Feature%20Tracking%20Study%5Cu201d%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Farah%22%2C%22lastName%22%3A%22Cadour%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Joevin%22%2C%22lastName%22%3A%22Sourdon%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22%22%2C%22date%22%3A%222024%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1002%5C%2Fjmri.29092%22%2C%22ISSN%22%3A%221522-2586%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fonlinelibrary.wiley.com%5C%2Fdoi%5C%2Fabs%5C%2F10.1002%5C%2Fjmri.29092%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%2C%226B37I9FA%22%5D%2C%22dateModified%22%3A%222025-09-12T07%3A59%3A26Z%22%7D%7D%2C%7B%22key%22%3A%223U764DN9%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Daud%5Cu00e9%20et%20al.%22%2C%22parsedDate%22%3A%222024%22%2C%22numChildren%22%3A0%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BDaud%26%23xE9%3B%2C%20P.%2C%20Roussel%2C%20T.%2C%20Troalen%2C%20T.%2C%20Viout%2C%20P.%2C%20Hernando%2C%20D.%2C%20Guye%2C%20M.%2C%20Kober%2C%20F.%2C%20Confort%20Gouny%2C%20S.%2C%20Bernard%2C%20M.%20and%20Rapacchi%2C%20S.%20%282024%29%20%26%23x201C%3BComparative%20review%20of%20algorithms%20and%20methods%20for%20chemical-shift-encoded%20quantitative%20fat-water%20imaging%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2091%282%29%2C%20pp.%20741%26%23x2013%3B759.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.29860%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.29860%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Comparative%20review%20of%20algorithms%20and%20methods%20for%20chemical-shift-encoded%20quantitative%20fat-water%20imaging%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Pierre%22%2C%22lastName%22%3A%22Daud%5Cu00e9%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Tangi%22%2C%22lastName%22%3A%22Roussel%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thomas%22%2C%22lastName%22%3A%22Troalen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Patrick%22%2C%22lastName%22%3A%22Viout%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Diego%22%2C%22lastName%22%3A%22Hernando%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%22%2C%22lastName%22%3A%22Kober%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Sylviane%22%2C%22lastName%22%3A%22Confort%20Gouny%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Monique%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22Purpose%20To%20propose%20a%20standardized%20comparison%20between%20state-of-the-art%20open-source%20fat-water%20separation%20algorithms%20for%20proton%20density%20fat%20fraction%20%28PDFF%29%20and%20R2%2A%5C%5C%20R_2%5E%5C%5Cast%20%5C%5C%20quantification%20using%20an%20open-source%20multi-language%20toolbox.%20Methods%20Eight%20recent%20open-source%20fat-water%20separation%20algorithms%20were%20compared%20in%20silico%2C%20in%20vitro%2C%20and%20in%20vivo.%20Multi-echo%20data%20were%20synthesized%20with%20varying%20fat-fractions%2C%20B0%20off-resonance%2C%20SNR%20and%20TEs.%20Experimental%20evaluation%20was%20conducted%20using%20calibrated%20fat-water%20phantoms%20acquired%20at%203T%20and%20multi-site%20open-source%20phantoms%20data.%20Algorithms%26%23039%3B%20performances%20were%20observed%20on%20challenging%20in%20vivo%20datasets%20at%203T.%20Finally%2C%20reconstruction%20algorithms%20were%20investigated%20with%20different%20fat%20spectra%20to%20evaluate%20the%20importance%20of%20the%20fat%20model.%20Results%20In%20silico%20and%20in%20vitro%20results%20proved%20most%20algorithms%20to%20be%20not%20sensitive%20to%20fat-water%20swaps%20and%20B0%5C%5C%20%5C%5CmathrmB_0%20%5C%5C%20offsets%20with%20five%20or%20more%20echoes.%20However%2C%20two%20methods%20remained%20inaccurate%20even%20with%20seven%20echoes%20and%20SNR%20%3D%2050%2C%20and%20two%20other%20algorithms%26%23039%3B%20precision%20depended%20on%20the%20echo%20spacing%20scheme%20%28p%20%26lt%3B%200.05%29.%20The%20remaining%20four%20algorithms%20provided%20reliable%20performances%20with%20limits%20of%20agreement%20under%202%25%20for%20PDFF%20and%206%20s%5Cu22121%20for%20R2%2A%5C%5C%20R_2%5E%5C%5Cast%20%5C%5C.%20The%20choice%20of%20fat%20spectrum%20model%20influenced%20quantification%20of%20PDFF%20mildly%20%28%26lt%3B2%25%20bias%29%20and%20of%20R2%2A%5C%5C%20R_2%5E%5C%5Cast%20%5C%5C%20more%20severely%2C%20with%20errors%20up%20to%2020%20s%5Cu22121.%20Conclusion%20In%20promoting%20standardized%20comparisons%20of%20MRI-based%20fat%20and%20iron%20quantification%20using%20chemical-shift%20encoded%20multi-echo%20methods%2C%20this%20benchmark%20work%20has%20revealed%20some%20discrepancies%20between%20recent%20approaches%20for%20PDFF%20and%20R2%2A%5C%5C%20R_2%5E%5C%5Cast%20%5C%5C%20mapping.%20Explicit%20choices%20and%20parameterization%20of%20the%20fat-water%20algorithm%20appear%20necessary%20for%20reproducibility.%20This%20open-source%20toolbox%20further%20enables%20the%20user%20to%20optimize%20acquisition%20parameters%20by%20predicting%20algorithms%26%23039%3B%20margins%20of%20errors.%22%2C%22date%22%3A%222024%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.29860%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fonlinelibrary.wiley.com%5C%2Fdoi%5C%2Fabs%5C%2F10.1002%5C%2Fmrm.29860%22%2C%22collections%22%3A%5B%227JR7EDKF%22%2C%226GBQDAVI%22%2C%225Z6CVJGB%22%2C%22SK6VWU7K%22%2C%22ACGLJ26R%22%2C%22XTA6KS7L%22%2C%22BR9D2SS4%22%5D%2C%22dateModified%22%3A%222025-09-12T07%3A59%3A14Z%22%7D%7D%2C%7B%22key%22%3A%22C4ETJLMJ%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Ogier%20et%20al.%22%2C%22parsedDate%22%3A%222023-04-29%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BOgier%2C%20A.C.%2C%20Rapacchi%2C%20S.%20and%20Bellemare%2C%20M.-E.%20%282023%29%20%26%23x201C%3BFour-dimensional%20reconstruction%20and%20characterization%20of%20bladder%20deformations%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BComputer%20Methods%20and%20Programs%20in%20Biomedicine%26lt%3B%5C%2Fi%26gt%3B%2C%20237%2C%20p.%20107569.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.cmpb.2023.107569%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.cmpb.2023.107569%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Four-dimensional%20reconstruction%20and%20characterization%20of%20bladder%20deformations%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Augustin%20C.%22%2C%22lastName%22%3A%22Ogier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Marc-Emmanuel%22%2C%22lastName%22%3A%22Bellemare%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%20AND%20OBJECTIVE%3A%20Pelvic%20floor%20disorders%20are%20prevalent%20diseases%20and%20patient%20care%20remains%20difficult%20as%20the%20dynamics%20of%20the%20pelvic%20floor%20remains%20poorly%20understood.%20So%20far%2C%20only%202D%20dynamic%20observations%20of%20straining%20exercises%20at%20excretion%20are%20available%20in%20the%20clinics%20and%203D%20mechanical%20defects%20of%20pelvic%20organs%20are%20not%20well%20studied.%20In%20this%20context%2C%20we%20propose%20a%20complete%20methodology%20for%20the%203D%20representation%20of%20non-reversible%20bladder%20deformations%20during%20exercises%2C%20combined%20with%20a%203D%20representation%20of%20the%20location%20of%20the%20highest%20strain%20areas%20on%20the%20organ%20surface.%5CnMETHODS%3A%20Novel%20image%20segmentation%20and%20registration%20approaches%20have%20been%20combined%20with%20three%20geometrical%20configurations%20of%20up-to-date%20rapid%20dynamic%20multi-slice%20MRI%20acquisitions%20for%20the%20reconstruction%20of%20real-time%20dynamic%20bladder%20volumes.%5CnRESULTS%3A%20For%20the%20first%20time%2C%20we%20proposed%20real-time%203D%20deformation%20fields%20of%20the%20bladder%20under%20strain%20from%20in-bore%20forced%20breathing%20exercises.%20The%20potential%20of%20our%20method%20was%20assessed%20on%20eight%20control%20subjects%20undergoing%20forced%20breathing%20exercises.%20We%20obtained%20average%20volume%20deviations%20of%20the%20reconstructed%20dynamic%20volume%20of%20bladders%20around%202.5%25%20and%20high%20registration%20accuracy%20with%20mean%20distance%20values%20of%200.4%20%5Cu00b1%200.3%5Cu00a0mm%20and%20Hausdorff%20distance%20values%20of%202.2%20%5Cu00b1%201.1%5Cu00a0mm.%5CnCONCLUSIONS%3A%20The%20proposed%20framework%20provides%20proper%203D%2Bt%20spatial%20tracking%20of%20non-reversible%20bladder%20deformations.%20This%20has%20immediate%20applicability%20in%20clinical%20settings%20for%20a%20better%20understanding%20of%20pelvic%20organ%20prolapse%20pathophysiology.%20This%20work%20can%20be%20extended%20to%20patients%20with%20cavity%20filling%20or%20excretion%20problems%20to%20better%20characterize%20the%20severity%20of%20pelvic%20floor%20pathologies%20or%20to%20be%20used%20for%20preoperative%20surgical%20planning.%22%2C%22date%22%3A%222023-04-29%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.cmpb.2023.107569%22%2C%22ISSN%22%3A%221872-7565%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22NW6SZQBR%22%2C%22SK6VWU7K%22%2C%2248SZ2I24%22%5D%2C%22dateModified%22%3A%222023-11-17T10%3A13%3A22Z%22%7D%7D%2C%7B%22key%22%3A%229Y63LXT8%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Cadour%20et%20al.%22%2C%22parsedDate%22%3A%222023-02-06%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BCadour%2C%20F.%2C%20Quemeneur%2C%20M.%2C%20Biere%2C%20L.%2C%20Donal%2C%20E.%2C%20Bentatou%2C%20Z.%2C%20Eicher%2C%20J.-C.%2C%20Roubille%2C%20F.%2C%20Lalande%2C%20A.%2C%20Giorgi%2C%20R.%2C%20Rapacchi%2C%20S.%2C%20Cortaredona%2C%20S.%2C%20Tradi%2C%20F.%2C%20Bartoli%2C%20A.%2C%20Willoteaux%2C%20S.%2C%20Delahaye%2C%20F.%2C%20Biene%2C%20S.M.%2C%20Mangin%2C%20L.%2C%20Ferrier%2C%20N.%2C%20Dacher%2C%20J.-N.%2C%20Bauer%2C%20F.%2C%20Leurent%2C%20G.%2C%20Lentz%2C%20P.-A.%2C%20Kovacsik%2C%20H.%2C%20Croisille%2C%20P.%2C%20Thuny%2C%20F.%2C%20Bernard%2C%20M.%2C%20Guye%2C%20M.%2C%20Furber%2C%20A.%2C%20Habib%2C%20G.%20and%20Jacquier%2C%20A.%20%282023%29%20%26%23x201C%3BPrognostic%20value%20of%20cardiovascular%20magnetic%20resonance%20T1%20mapping%20and%20extracellular%20volume%20fraction%20in%20nonischemic%20dilated%20cardiomyopathy%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BJournal%20of%20Cardiovascular%20Magnetic%20Resonance%3A%20Official%20Journal%20of%20the%20Society%20for%20Cardiovascular%20Magnetic%20Resonance%26lt%3B%5C%2Fi%26gt%3B%2C%2025%281%29%2C%20p.%207.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1186%5C%2Fs12968-023-00919-y%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1186%5C%2Fs12968-023-00919-y%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Prognostic%20value%20of%20cardiovascular%20magnetic%20resonance%20T1%20mapping%20and%20extracellular%20volume%20fraction%20in%20nonischemic%20dilated%20cardiomyopathy%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Farah%22%2C%22lastName%22%3A%22Cadour%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Morgane%22%2C%22lastName%22%3A%22Quemeneur%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Loic%22%2C%22lastName%22%3A%22Biere%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Erwan%22%2C%22lastName%22%3A%22Donal%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Zakarya%22%2C%22lastName%22%3A%22Bentatou%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jean-Christophe%22%2C%22lastName%22%3A%22Eicher%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fran%5Cu00e7ois%22%2C%22lastName%22%3A%22Roubille%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alain%22%2C%22lastName%22%3A%22Lalande%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Roch%22%2C%22lastName%22%3A%22Giorgi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22S%5Cu00e9bastien%22%2C%22lastName%22%3A%22Cortaredona%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Farouk%22%2C%22lastName%22%3A%22Tradi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Axel%22%2C%22lastName%22%3A%22Bartoli%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Serge%22%2C%22lastName%22%3A%22Willoteaux%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fran%5Cu00e7ois%22%2C%22lastName%22%3A%22Delahaye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stephanie%20M.%22%2C%22lastName%22%3A%22Biene%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lionel%22%2C%22lastName%22%3A%22Mangin%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Nadine%22%2C%22lastName%22%3A%22Ferrier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jean-Nicolas%22%2C%22lastName%22%3A%22Dacher%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fabrice%22%2C%22lastName%22%3A%22Bauer%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Guillaume%22%2C%22lastName%22%3A%22Leurent%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Pierre-Axel%22%2C%22lastName%22%3A%22Lentz%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22H%5Cu00e9l%5Cu00e8ne%22%2C%22lastName%22%3A%22Kovacsik%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Pierre%22%2C%22lastName%22%3A%22Croisille%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Franck%22%2C%22lastName%22%3A%22Thuny%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Monique%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alain%22%2C%22lastName%22%3A%22Furber%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Gilbert%22%2C%22lastName%22%3A%22Habib%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alexis%22%2C%22lastName%22%3A%22Jacquier%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%3A%20Heart%20failure-%20%28HF%29%20and%20arrhythmia-related%20complications%20are%20the%20main%20causes%20of%20morbidity%20and%20mortality%20in%20patients%20with%20nonischemic%20dilated%20cardiomyopathy%20%28NIDCM%29.%20Cardiovascular%20magnetic%20resonance%20%28CMR%29%20imaging%20is%20a%20noninvasive%20tool%20for%20risk%20stratification%20based%20on%20fibrosis%20assessment.%20Diffuse%20interstitial%20fibrosis%20in%20NIDCM%20may%20be%20a%20limitation%20for%20fibrosis%20assessment%20through%20late%20gadolinium%20enhancement%20%28LGE%29%2C%20which%20might%20be%20overcome%20through%20quantitative%20T1%20and%20extracellular%20volume%20%28ECV%29%20assessment.%20T1%20and%20ECV%20prognostic%20value%20for%20arrhythmia-related%20events%20remain%20poorly%20investigated.%20We%20asked%20whether%20T1%20and%20ECV%20have%20a%20prognostic%20value%20in%20NIDCM%20patients.%5CnMETHODS%3A%20This%20prospective%20multicenter%20study%20analyzed%20225%20patients%20with%20NIDCM%20confirmed%20by%20CMR%20who%20were%20followed%20up%20for%202%5Cu00a0years.%20CMR%20evaluation%20included%20LGE%2C%20native%20T1%20mapping%20and%20ECV%20values.%20The%20primary%20endpoint%20was%20the%20occurrence%20of%20a%20major%20adverse%20cardiovascular%20event%20%28MACE%29%20which%20was%20divided%20in%20two%20groups%3A%20HF-related%20events%20and%20arrhythmia-related%20events.%20Optimal%20cutoffs%20for%20prediction%20of%20MACE%20occurrence%20were%20calculated%20for%20all%20CMR%20quantitative%20values.%5CnRESULTS%3A%20Fifty-eight%20patients%20%2826%25%29%20developed%20a%20MACE%20during%20follow-up%2C%2042%20patients%20%2819%25%29%20with%20HF-related%20events%20and%2016%20patients%20%287%25%29%20arrhythmia-related%20events.%20T1%20Z-score%20%28p%5Cu2009%3D%5Cu20090.008%29%20and%20global%20ECV%20%28p%5Cu2009%3D%5Cu20090.001%29%20were%20associated%20with%20HF-related%20events%20occurrence%2C%20in%20addition%20to%20left%20ventricular%20ejection%20fraction%20%28p%5Cu2009%26lt%3B%5Cu20090.001%29.%20ECV%5Cu2009%26gt%3B%5Cu200932.1%25%20%28optimal%20cutoff%29%20remained%20the%20only%20CMR%20independent%20predictor%20of%20HF-related%20events%20occurrence%20%28HR%202.15%20%5B1.14-4.07%5D%2C%20p%5Cu2009%3D%5Cu20090.018%29.%20In%20the%20arrhythmia-related%20events%20group%2C%20patients%20had%20increased%20native%20T1%20Z-score%20and%20ECV%20values%2C%20with%20both%20T1%20Z-score%5Cu2009%26gt%3B%5Cu20094.2%20and%20ECV%5Cu2009%26gt%3B%5Cu200930.5%25%20%28optimal%20cutoffs%29%20being%20independent%20predictors%20of%20arrhythmia-related%20events%20occurrence%20%28respectively%2C%20HR%202.86%20%5B1.06-7.68%5D%2C%20p%5Cu2009%3D%5Cu20090.037%20and%20HR%202.72%20%5B1.01-7.36%5D%2C%20p%5Cu2009%3D%5Cu20090.049%29.%5CnCONCLUSIONS%3A%20ECV%20was%20the%20sole%20independent%20predictive%20factor%20for%20both%20HF-%20and%20arrhythmia-related%20events%20in%20NIDCM%20patients.%20Native%20T1%20was%20also%20an%20independent%20predictor%20in%20arrhythmia-related%20events%20occurrence.%20The%20addition%20of%20ECV%20and%20more%20importantly%20native%20T1%20in%20the%20decision-making%20algorithm%20may%20improve%20arrhythmia%20risk%20stratification%20in%20NIDCM%20patients.%20Trial%20registration%20NCT02352129.%20Registered%202nd%20February%202015-Retrospectively%20registered%2C%20https%3A%5C%2F%5C%2Fclinicaltrials.gov%5C%2Fct2%5C%2Fshow%5C%2FNCT02352129.%22%2C%22date%22%3A%222023-02-06%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1186%5C%2Fs12968-023-00919-y%22%2C%22ISSN%22%3A%221532-429X%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%225Z6CVJGB%22%2C%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22B4FUISBZ%22%2C%22XTA6KS7L%22%2C%22CXAMISN8%22%5D%2C%22dateModified%22%3A%222024-06-14T08%3A30%3A10Z%22%7D%7D%2C%7B%22key%22%3A%22X94Y4MT9%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Garcia%20Hernandez%20et%20al.%22%2C%22parsedDate%22%3A%222023-01%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BGarcia%20Hernandez%2C%20A.%2C%20Fau%2C%20P.%2C%20Wojak%2C%20J.%2C%20Mailleux%2C%20H.%2C%20Benkreira%2C%20M.%2C%20Rapacchi%2C%20S.%20and%20Adel%2C%20M.%20%282023%29%20%26%23x201C%3BSynthetic%20computed%20tomography%20generation%20for%20abdominal%20adaptive%20radiotherapy%20using%20low-field%20magnetic%20resonance%20imaging%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BPhysics%20and%20Imaging%20in%20Radiation%20Oncology%26lt%3B%5C%2Fi%26gt%3B%2C%2025%2C%20p.%20100425.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.phro.2023.100425%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.phro.2023.100425%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Synthetic%20computed%20tomography%20generation%20for%20abdominal%20adaptive%20radiotherapy%20using%20low-field%20magnetic%20resonance%20imaging%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Armando%22%2C%22lastName%22%3A%22Garcia%20Hernandez%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Pierre%22%2C%22lastName%22%3A%22Fau%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Julien%22%2C%22lastName%22%3A%22Wojak%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Hugues%22%2C%22lastName%22%3A%22Mailleux%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Mohamed%22%2C%22lastName%22%3A%22Benkreira%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Mouloud%22%2C%22lastName%22%3A%22Adel%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%20AND%20PURPOSE%3A%20Magnetic%20Resonance%20guided%20Radiotherapy%20%28MRgRT%29%20still%20needs%20the%20acquisition%20of%20Computed%20Tomography%20%28CT%29%20images%20and%20co-registration%20between%20CT%20and%20Magnetic%20Resonance%20Imaging%20%28MRI%29.%20The%20generation%20of%20synthetic%20CT%20%28sCT%29%20images%20from%20the%20MR%20data%20can%20overcome%20this%20limitation.%20In%20this%20study%20we%20aim%20to%20propose%20a%20Deep%20Learning%20%28DL%29%20based%20approach%20for%20sCT%20image%20generation%20for%20abdominal%20Radiotherapy%20using%20low%20field%20MR%20images.%5CnMATERIALS%20AND%20METHODS%3A%20CT%20and%20MR%20images%20were%20collected%20from%2076%20patients%20treated%20on%20abdominal%20sites.%20U-Net%20and%20conditional%20Generative%20Adversarial%20Network%20%28cGAN%29%20architectures%20were%20used%20to%20generate%20sCT%20images.%20Additionally%2C%20sCT%20images%20composed%20of%20only%20six%20bulk%20densities%20were%20generated%20with%20the%20aim%20of%20having%20a%20Simplified%20sCT.Radiotherapy%20plans%20calculated%20using%20the%20generated%20images%20were%20compared%20to%20the%20original%20plan%20in%20terms%20of%20gamma%20pass%20rate%20and%20Dose%20Volume%20Histogram%20%28DVH%29%20parameters.%5CnRESULTS%3A%20sCT%20images%20were%20generated%20in%202%5Cu00a0s%20and%202.5%5Cu00a0s%20with%20U-Net%20and%20cGAN%20architectures%20respectively.Gamma%20pass%20rates%20for%202%25%5C%2F2mm%20and%203%25%5C%2F3mm%20criteria%20were%2091%25%20and%2095%25%20respectively.%20Dose%20differences%20within%201%25%20for%20DVH%20parameters%20on%20the%20target%20volume%20and%20organs%20at%20risk%20were%20obtained.%5CnCONCLUSION%3A%20U-Net%20and%20cGAN%20architectures%20are%20able%20to%20generate%20abdominal%20sCT%20images%20fast%20and%20accurately%20from%20low%20field%20MRI.%22%2C%22date%22%3A%222023-01%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.phro.2023.100425%22%2C%22ISSN%22%3A%222405-6316%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222025-03-31T14%3A24%3A36Z%22%7D%7D%2C%7B%22key%22%3A%22DY56QM2E%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Marage%20et%20al.%22%2C%22parsedDate%22%3A%222022-12%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BMarage%2C%20L.%2C%20Walker%2C%20P.-M.%2C%20Boudet%2C%20J.%2C%20Fau%2C%20P.%2C%20Debuire%2C%20P.%2C%20Clausse%2C%20E.%2C%20Petitfils%2C%20A.%2C%20Aubignac%2C%20L.%2C%20Rapacchi%2C%20S.%20and%20Bessieres%2C%20I.%20%282022%29%20%26%23x201C%3BCharacterisation%20of%20a%20split%20gradient%20coil%20design%20induced%20systemic%20imaging%20artefact%20on%200.35%20T%20MR-linac%20systems%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BPhysics%20in%20Medicine%20%26amp%3B%20Biology%26lt%3B%5C%2Fi%26gt%3B%2C%2068%281%29%2C%20p.%2001NT03.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1088%5C%2F1361-6560%5C%2Faca876%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1088%5C%2F1361-6560%5C%2Faca876%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Characterisation%20of%20a%20split%20gradient%20coil%20design%20induced%20systemic%20imaging%20artefact%20on%200.35%20T%20MR-linac%20systems%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Louis%22%2C%22lastName%22%3A%22Marage%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Paul-Michael%22%2C%22lastName%22%3A%22Walker%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Julien%22%2C%22lastName%22%3A%22Boudet%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Pierre%22%2C%22lastName%22%3A%22Fau%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Pierre%22%2C%22lastName%22%3A%22Debuire%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Emmanuelle%22%2C%22lastName%22%3A%22Clausse%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Aur%5Cu00e9lie%22%2C%22lastName%22%3A%22Petitfils%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22L%5Cu00e9one%22%2C%22lastName%22%3A%22Aubignac%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Igor%22%2C%22lastName%22%3A%22Bessieres%22%7D%5D%2C%22abstractNote%22%3A%22Objective.%20The%20aim%20of%20this%20work%20was%20to%20highlight%20and%20characterize%20a%20systemic%20%5Cu2018star-like%5Cu2019%20artefact%20inherent%20to%20the%20low%20field%200.35%20T%20MRIdian%20MR-linac%20system%2C%20a%20magnetic%20resonance%20guided%20radiotherapy%20device.%20This%20artefact%20is%20induced%20by%20the%20original%20split%20gradients%20coils%20design.%20This%20design%20causes%20a%20surjection%20of%20the%20intensity%20gradient%20in%20Z%20%28or%20head-feet%29%20direction.%20This%20artefact%20appears%20on%20every%20sequence%20with%20phase%20encoding%20in%20the%20head-feet%20direction.%20Approach.%20Basic%20gradient%20echo%20sequence%20and%20clinical%20mandatory%20bSSFP%20sequence%20were%20used.%20Three%20setups%20using%20manufacturer%20provided%20QA%20phantoms%20were%20designed%3A%20two%20including%20the%20linearity%20control%20grid%20used%20for%20the%20characterisation%20and%20a%20third%20including%20two%20homogeneity%20control%20spheres%20dedicated%20to%20the%20artefact%20management%20in%20a%20more%20clinical%20like%20situation.%20The%20presence%20of%20the%20artefact%20was%20checked%20in%20four%20different%20MRidian%20sites.%20The%20tested%20parameters%20based%20on%20the%20literature%20were%3A%20phase%20encoding%20orientation%2C%20slab%20selectivity%2C%20excitation%20bandwidth%20%28BWRF%29%2C%20acceleration%20factor%20%28R%29%20and%20phase%5C%2Fslab%20oversampling%20%28PO%5C%2FSO%29.%20Main%20results.%20The%20position%20of%20this%20artefact%20is%20constant%20and%20reproducible%20over%20the%20tested%20MRIdian%20sites.%20The%20typical%20singularity%20saturated%20dot%20or%20star%20is%20visible%20even%20with%20the%203D%20slab-selection%20enabled.%20A%20management%20is%20proposed%20by%20decreasing%20the%20BWRF%2C%20the%20R%20in%20head-feet%20direction%20and%20increasing%20the%20PO%5C%2FSO.%20The%20oversampling%20can%20be%20optimized%20using%20a%20formula%20to%20anticipate%20the%20location%20of%20artefact%20in%20the%20field%20of%20view.%20Significance.%20The%20star-like%20artefact%20has%20been%20well%20characterised.%20A%20manageable%20solution%20comes%20at%20the%20cost%20of%20acquisition%20time.%20Observed%20in%20clinical%20cases%2C%20the%20artefact%20may%20degrade%20the%20images%20used%20for%20the%20RT%20planning%20and%20repositioning%20during%20the%20treatment%20unless%20corrected.%22%2C%22date%22%3A%222022-12%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1088%5C%2F1361-6560%5C%2Faca876%22%2C%22ISSN%22%3A%220031-9155%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fdx.doi.org%5C%2F10.1088%5C%2F1361-6560%5C%2Faca876%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222023-11-23T10%3A41%3A11Z%22%7D%7D%2C%7B%22key%22%3A%224I3CWWJR%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Silva-Verissimo%20et%20al.%22%2C%22parsedDate%22%3A%222022-11-20%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BSilva-Verissimo%2C%20W.%2C%20El%20Louali%2C%20F.%2C%20Godio-Raboutet%2C%20Y.%2C%20Leblond%2C%20L.%2C%20Sourdon%2C%20J.%2C%20Rapacchi%2C%20S.%20and%20Evin%2C%20M.%20%282022%29%20%26%23x201C%3BTraction%20mechanical%20characterization%20of%20porcine%20mitral%20valve%20annulus%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BJournal%20of%20Biomechanics%26lt%3B%5C%2Fi%26gt%3B%2C%20146%2C%20p.%20111396.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.jbiomech.2022.111396%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.jbiomech.2022.111396%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Traction%20mechanical%20characterization%20of%20porcine%20mitral%20valve%20annulus%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22W.%22%2C%22lastName%22%3A%22Silva-Verissimo%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22F.%22%2C%22lastName%22%3A%22El%20Louali%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Y.%22%2C%22lastName%22%3A%22Godio-Raboutet%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lugdivine%22%2C%22lastName%22%3A%22Leblond%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Joevin%22%2C%22lastName%22%3A%22Sourdon%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22S.%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Morgane%22%2C%22lastName%22%3A%22Evin%22%7D%5D%2C%22abstractNote%22%3A%22The%20Mitral%20Annulus%20%28MA%29%20is%20an%20anisotropic%2C%20fibrous%2C%20flexible%20and%20dynamical%20structure.%20While%20MA%20dynamics%20are%20well%20documented%2C%20its%20passive%20mechanical%20properties%20remain%20poorly%20investigated%20to%20complete%20the%20design%20of%20adequate%20prostheses.%20Mechanical%20properties%20in%20traction%20on%20four%20sections%20of%20the%20MA%20%28aortic%2C%20left%2C%20posterior%20and%20right%20segments%29%20were%20assessed%20using%20a%20traction%20test%20system%20with%20a%2030%5Cu00a0N%20load%20cell%20and%20pulling%20jaws%20for%20sample%20fixation.%20Samples%20were%20submitted%20to%20a%201.5%5Cu00a0N%20pre-load%2C%2010%20pre-conditioning%20cycles.%20Three%20strain%20rates%20were%20tested%20%285%5Cu00a0%25%5C%2Fmin%2C%207%5Cu00a0%25%5C%2Fmin%20and%2013%5Cu00a0%25%5C%2Fmin%29%2C%20the%20first%20two%20up%20to%2010%5Cu00a0%25%20strain%20and%20the%20last%20until%20rupture.%20High-resolution%20diffusion-MRI%20provided%20microstructural%20mapping%20of%20fractional%20anisotropy%20and%20mean%20diffusion%20within%20muscle%20and%20collagen%20fibres.%20Ten%20MA%20from%20porcine%20hearts%20were%20excised%20resulting%20in%2040%20tested%20samples%2C%20out%20of%20which%2028%20were%20frozen%20prior%20to%20testing.%20Freezing%20samples%20significantly%20increased%20Young%20Moduli%20for%20all%20strain%20rates.%20No%20significant%20differences%20were%20found%20between%20Young%20Moduli%20at%20different%20strain%20rates%20%28fresh%20samples%202.4%5Cu00a0%5Cu00b1%5Cu00a01.1%5Cu00a0MPa%2C%203.8%5Cu00a0%5Cu00b1%5Cu00a02.2%5Cu00a0MPa%20and%203.1%5Cu00a0%5Cu00b1%5Cu00a01.8%5Cu00a0MPa%20for%20increasing%20strain%20rates%20in%20fresh%20samples%29%2C%20while%20significant%20differences%20were%20found%20when%20comparing%20aortic%20with%20posterior%20and%20posterior%20with%20lateral%20%28p%5Cu00a0%26lt%3B%5Cu00a00.012%29.%20Aortic%20segments%20deformed%20the%20most%20%2824.1%5Cu00a0%5Cu00b1%5Cu00a09.4%5Cu00a0%25%29%20while%20lateral%20segments%20endured%20the%20highest%20stress%20%28%26gt%3B0.3%5Cu00a0MPa%29%2C%20corresponding%20to%20higher%20collagen%20fraction%20%280.46%29%20and%20fractional%20anisotropy.%20Passive%20machinal%20properties%20differed%20between%20aortic%20and%20lateral%20segments%20of%20the%20MA.%20The%20process%20of%20freezing%20samples%20altered%20their%20mechanical%20properties.%20Underlying%20microstructural%20differences%20could%20be%20linked%20to%20changes%20in%20strain%20response.%22%2C%22date%22%3A%222022-11-20%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.jbiomech.2022.111396%22%2C%22ISSN%22%3A%221873-2380%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%2C%226B37I9FA%22%5D%2C%22dateModified%22%3A%222022-12-05T09%3A15%3A11Z%22%7D%7D%2C%7B%22key%22%3A%2249Y55MKR%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Cadour%20et%20al.%22%2C%22parsedDate%22%3A%222022-06%22%2C%22numChildren%22%3A0%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BCadour%2C%20F.%2C%20Cautela%2C%20J.%2C%20Rapacchi%2C%20S.%2C%20Varoquaux%2C%20A.%2C%20Habert%2C%20P.%2C%20Arnaud%2C%20F.%2C%20Jacquier%2C%20A.%2C%20Meilhac%2C%20A.%2C%20Paganelli%2C%20F.%2C%20Lalev%26%23xE9%3Be%2C%20N.%2C%20Scemama%2C%20U.%20and%20Thuny%2C%20F.%20%282022%29%20%26%23x201C%3BCardiac%20MRI%20Features%20and%20Prognostic%20Value%20in%20Immune%20Checkpoint%20Inhibitor%26%23x2013%3Binduced%20Myocarditis%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BRadiology%26lt%3B%5C%2Fi%26gt%3B%2C%20303%283%29%2C%20pp.%20512%26%23x2013%3B521.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1148%5C%2Fradiol.211765%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1148%5C%2Fradiol.211765%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Cardiac%20MRI%20Features%20and%20Prognostic%20Value%20in%20Immune%20Checkpoint%20Inhibitor%5Cu2013induced%20Myocarditis%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Farah%22%2C%22lastName%22%3A%22Cadour%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jennifer%22%2C%22lastName%22%3A%22Cautela%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Arthur%22%2C%22lastName%22%3A%22Varoquaux%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Paul%22%2C%22lastName%22%3A%22Habert%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fran%5Cu00e7ois%22%2C%22lastName%22%3A%22Arnaud%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alexis%22%2C%22lastName%22%3A%22Jacquier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alexandra%22%2C%22lastName%22%3A%22Meilhac%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Franck%22%2C%22lastName%22%3A%22Paganelli%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Nathalie%22%2C%22lastName%22%3A%22Lalev%5Cu00e9e%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ugo%22%2C%22lastName%22%3A%22Scemama%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Franck%22%2C%22lastName%22%3A%22Thuny%22%7D%5D%2C%22abstractNote%22%3A%22Background%5Cn%5CnCardiac%20MRI%20features%20are%20not%20well-defined%20in%20immune%20checkpoint%20inhibitor%20%28ICI%29%5Cu2013induced%20myocarditis%20%28ICI-M%29%2C%20a%20severe%20complication%20of%20ICI%20therapy%20in%20patients%20with%20cancer.%5Cn%5CnPurpose%5Cn%5CnTo%20analyze%20the%20cardiac%20MRI%20features%20of%20ICI-M%20and%20to%20explore%20their%20prognostic%20value%20in%20major%20adverse%20cardiovascular%20events%20%28MACE%29.%5Cn%5CnMaterials%20and%20Methods%5Cn%5CnIn%20this%20retrospective%20study%20from%20May%202017%20to%20January%202020%2C%20cardiac%20MRI%20findings%20%28including%20late%20gadolinium%20enhancement%20%5BLGE%5D%2C%20T1%20and%20T2%20mapping%2C%20and%20extracellular%20volume%20fraction%20%5BECV%5D%20z%20scores%29%20of%20patients%20with%20ICI-M%20were%20compared%20with%20those%20of%20patients%20with%20cancer%20scheduled%20to%20receive%20ICI%20therapy%20%28pre-ICI%20group%29%20and%20patients%20with%20viral%20myocarditis.%20As%20a%20secondary%20objective%2C%20the%20potential%20value%20of%20cardiac%20MRI%20for%20predicting%20MACE%20in%20patients%20with%20ICI-M%20by%20using%20Cox%20proportional%20hazards%20models%20was%20explored.%5Cn%5CnResults%5Cn%5CnThirty-three%20patients%20with%20ICI-M%20%28mean%20age%20%5Cu00b1%20standard%20deviation%2C%2068%20years%20%5Cu00b1%2014%3B%2023%20men%29%20were%20compared%20with%2021%20patients%20scheduled%20to%20receive%20to%20ICI%20therapy%20%28mean%20age%2C%2065%20years%20%5Cu00b1%2014%3B%2014%20men%29%20and%2085%20patients%20with%20viral%20myocarditis%20%28mean%20age%2C%2032%20years%20%5Cu00b1%2013%3B%2067%20men%29.%20Compared%20with%20the%20pre-ICI%20group%2C%20patients%20with%20ICI-M%20showed%20higher%20global%20native%20T1%2C%20ECV%2C%20and%20T2%20z%20scores%20%280.03%20%5Cu00b1%200.85%20vs%201.79%20%5Cu00b1%201.93%20%5BP%20%26lt%3B%20.001%5D%3B%201.34%20%5Cu00b1%200.57%20vs%202.59%20%5Cu00b1%201.97%20%5BP%20%3D%20.03%5D%3B%20and%20%5Cu20130.76%20%5Cu00b1%201.41%20vs%200.88%20%5Cu00b1%201.96%20%5BP%20%3D%20.002%5D%2C%20respectively%29%2C%20and%20LGE%20was%20more%20frequently%20observed%20%2827%20of%2033%20patients%20%5B82%25%5D%20vs%20two%20of%2021%20%5B10%25%5D%3B%20P%20%26lt%3B%20.001%29.%20LGE%20was%20less%20frequent%20in%20patients%20with%20ICI-M%20than%20those%20with%20viral%20myocarditis%20%2827%20of%2033%20patients%20%5B82%25%5D%20vs%2085%20of%2085%20%5B100%25%5D%3B%20P%20%26lt%3B%20.001%29%20but%20was%20more%20likely%20to%20involve%20the%20septal%20segments%20%2816%20of%2033%20patients%20%5B48%25%5D%20vs%2025%20of%2085%20%5B29%25%5D%3B%20P%20%26lt%3B%20.001%29%20and%20midwall%20layer%20%2811%20of%2033%20patients%20%5B33%25%5D%20vs%20two%20of%2085%20%5B2%25%5D%3B%20P%20%26lt%3B%20.001%29.%20Septal%20LGE%20was%20the%20only%20cardiac%20MRI%20predictor%20of%20MACE%20at%201%20year%20even%20after%20adjustment%20for%20peak%20troponin%20%28adjusted%20hazard%20ratio%2C%202.7%20%5B95%25%20CI%3A%201.1%2C%206.7%5D%3B%20P%20%3D%20.03%29.%5Cn%5CnConclusion%5Cn%5CnCardiac%20MRI%20features%20of%20immune%20checkpoint%20inhibitor%20%28ICI%29%5Cu2013induced%20myocarditis%20%28ICI-M%29%20seem%20to%20differ%20from%20those%20in%20patients%20scheduled%20to%20receive%20ICIs%20and%20patients%20with%20viral%20myocarditis.%20Septal%20late%20gadolinium%20enhancement%20might%20be%20a%20predictor%20of%20major%20cardiovascular%20events%20in%20patients%20with%20ICI-M.%5Cn%5CnClinical%20trial%20registration%20no.%20NCT03313544%5Cn%5Cn%5Cu00a9%20RSNA%2C%202022%5Cn%5CnOnline%20supplemental%20material%20is%20available%20for%20this%20article.%5Cn%5CnSee%20also%20the%20editorial%20by%20Edelman%20and%20Pursnani%20in%20this%20issue.%22%2C%22date%22%3A%222022-06%22%2C%22language%22%3A%22%22%2C%22DOI%22%3A%2210.1148%5C%2Fradiol.211765%22%2C%22ISSN%22%3A%220033-8419%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fpubs.rsna.org%5C%2Fdoi%5C%2F10.1148%5C%2Fradiol.211765%22%2C%22collections%22%3A%5B%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22KBIRKXGV%22%5D%2C%22dateModified%22%3A%222025-03-19T13%3A32%3A19Z%22%7D%7D%2C%7B%22key%22%3A%22AQTJ28R6%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Hoesl%20et%20al.%22%2C%22parsedDate%22%3A%222022-05-01%22%2C%22numChildren%22%3A0%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BHoesl%2C%20M.A.U.%2C%20Schad%2C%20L.R.%20and%20Rapacchi%2C%20S.%20%282022%29%20%26%23x201C%3BVolumetric%2023Na%20Single%20and%20Triple-Quantum%20Imaging%20at%207T%3A%203D-CRISTINA%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BZeitschrift%20f%26%23xFC%3Br%20Medizinische%20Physik%26lt%3B%5C%2Fi%26gt%3B%2C%2032%282%29%2C%20pp.%20199%26%23x2013%3B208.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.zemedi.2021.09.001%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.zemedi.2021.09.001%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Volumetric%2023Na%20Single%20and%20Triple-Quantum%20Imaging%20at%207T%3A%203D-CRISTINA%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Michaela%20A.%20U.%22%2C%22lastName%22%3A%22Hoesl%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lothar%20R.%22%2C%22lastName%22%3A%22Schad%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22Purpose%5CnTo%20measure%20multi-quantum%20coherence%20%28MQC%29%2023Na%20signals%20for%20noninvasive%20cell%20physiological%20information%20in%20the%20whole-brain%2C%20the%202D-CRISTINA%20method%20was%20extended%20to%203D.%20This%20experimental%20study%20investigated%20the%20use%20and%20results%20of%20a%20new%20sequence%2C%203D-CRISTINA%2C%20on%20a%20phantom%20and%20healthy%20volunteers.%5CnMethods%5CnThe%203D%20Cartesian%20single%20and%20triple-quantum%20imaging%20of%2023Na%20%283D-CRISTINA%29%20was%20developed%20and%20implemented%20at%207T%2C%20favoring%20a%20non-selective%20volume%20excitation%20for%20increased%20signal-to-noise%20ratio%20%28SNR%29%20and%20lower%20energy%20deployment%20than%20its%202D%20counterpart.%20Two%20independent%20phase%20cycles%20were%20used%20in%20analogy%20to%20the%202D%20method.%20A%20comparison%20of%206-steps%20cycles%20and%2012-steps%20cycles%20was%20performed.%20We%20used%20a%20phantom%20composed%20of%20different%20sodium%20and%20agarose%20concentrations%2C%2050mM%20to%20150mM%20Na%2B%2C%20and%200%5Cu20135%25%20agarose%20for%20sequence%20validation.%20Four%20healthy%20volunteers%20were%20scanned%20at%207T%20for%20whole%20brain%20MQC%20imaging.%20The%20sequence%203D-CRISTINA%20was%20developed%20and%20tested%20at%207T.%5CnResults%5CnAt%207T%2C%20the%203D-CRISTINA%20acquisition%20allowed%20to%20reduce%20the%20TR%20to%20230ms%20from%20the%20previous%20390ms%20for%202D%2C%20resulting%20in%20a%20total%20acquisition%20time%20of%2053min%20for%20a%203D%20volume%20of%204%5Cu00d74%5Cu00d78mm%20resolution.%20The%20phase%20cycle%20evaluation%20showed%20that%20the%207T%20acquisition%20time%20could%20be%20reduced%20by%204-fold%20with%20moderate%20single%20and%20triple-quantum%20signals%20SNR%20loss.%20The%20healthy%20volunteers%20demonstrated%20clinical%20feasibility%20at%207T%20and%20showed%20a%20difference%20in%20the%20MQC%20signals%20ratio%20of%20White%20Matter%20%28WM%29%20and%20Grey%20Matter%20%28GM%29.%5CnConclusion%5CnVolumetric%20CRISTINA%20multi-quantum%20imaging%20allowed%20whole-brain%20coverage.%20The%20non-selective%20excitation%20enabled%20a%20faster%20scan%20due%20to%20a%20decrease%20in%20energy%20deposition%20which%20enabled%20a%20lower%20repetition%20time.%20Thus%2C%20it%20should%20be%20the%20preferred%20choice%20for%20future%20in%20vivo%20multi-quantum%20applications%20compared%20to%20the%202D%20method.%20A%20more%20extensive%20study%20is%20warranted%20to%20explore%20WM%20and%20GM%20MQC%20differences.%22%2C%22date%22%3A%222022-05-01%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.zemedi.2021.09.001%22%2C%22ISSN%22%3A%220939-3889%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fwww.sciencedirect.com%5C%2Fscience%5C%2Farticle%5C%2Fpii%5C%2FS0939388921000830%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222024-03-22T09%3A22%3A17Z%22%7D%7D%2C%7B%22key%22%3A%22XBEHSSQE%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Vergara%20Gomez%20et%20al.%22%2C%22parsedDate%22%3A%222022-02-01%22%2C%22numChildren%22%3A0%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BVergara%20Gomez%2C%20T.S.%2C%20Dubois%2C%20M.%2C%20Rustomji%2C%20K.%2C%20Georget%2C%20E.%2C%20Antonakakis%2C%20T.%2C%20Vignaud%2C%20A.%2C%20Rapacchi%2C%20S.%2C%20Girard%2C%20O.M.%2C%20Kober%2C%20F.%2C%20Enoch%2C%20S.%20and%20Abdeddaim%2C%20R.%20%282022%29%20%26%23x201C%3BHilbert%20fractal%20inspired%20dipoles%20for%20passive%20RF%20shimming%20in%20ultra-high%20field%20MRI%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BPhotonics%20and%20Nanostructures%20-%20Fundamentals%20and%20Applications%26lt%3B%5C%2Fi%26gt%3B%2C%2048%2C%20p.%20100988.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.photonics.2021.100988%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.photonics.2021.100988%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Hilbert%20fractal%20inspired%20dipoles%20for%20passive%20RF%20shimming%20in%20ultra-high%20field%20MRI%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Tania%20S.%22%2C%22lastName%22%3A%22Vergara%20Gomez%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Marc%22%2C%22lastName%22%3A%22Dubois%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Kaizad%22%2C%22lastName%22%3A%22Rustomji%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Elodie%22%2C%22lastName%22%3A%22Georget%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Tryfon%22%2C%22lastName%22%3A%22Antonakakis%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alexandre%22%2C%22lastName%22%3A%22Vignaud%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Olivier%20M.%22%2C%22lastName%22%3A%22Girard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%22%2C%22lastName%22%3A%22Kober%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stefan%22%2C%22lastName%22%3A%22Enoch%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Redha%22%2C%22lastName%22%3A%22Abdeddaim%22%7D%5D%2C%22abstractNote%22%3A%22Ultra-high%20field%20MRI%20head%20coils%20present%20a%20characteristic%20B1%2B%20magnetic%20field%20distribution%20resulting%20in%20inhomogeneous%20signal%20and%20contrast%20over%20the%20image%2C%20affecting%20relevant%20regions%20of%20interest%20such%20as%20the%20temporal%20lobes%20of%20the%20brain%20and%20the%20cerebellum.%20This%20is%20a%20consequence%20of%20the%20spatially%20varying%20flip%20angle%20distribution%20attributed%20to%20the%20reduction%20of%20the%20electromagnetic%20wavelength%20inside%20the%20human%20tissues.%20Without%20radical%20changes%20in%20the%20experimental%20setup%2C%20this%20problem%20has%20been%20effectively%20targeted%20by%20different%20passive%20RF%20shimming%20approaches%20such%20as%20high%20permittivity%20dielectric%20pads%20or%20metamaterials.%20The%20latter%2C%20however%2C%20may%20potentially%20decrease%20the%20B1%2B%20field%20in%20other%20relevant%20areas%20or%20compromise%20the%20patient%5Cu2019s%20comfort.%20Here%2C%20we%20present%20a%20novel%20approach%20based%20on%20meander%20dipoles%20inspired%20from%20Hilbert%20fractals.%20The%20structures%20were%20designed%20and%20studied%20numerically%20using%20finite%20element%20simulations.%20Prototypes%20of%20the%20structures%20were%20printed%20and%20tested%20with%20a%201Tx%5C%2F32Rx%20birdcage%20head%20coil%20on%20a%207%5Cu00a0T%20MR%20scanner.%20We%20demonstrate%20a%20new%20device%20based%20on%20compact%2C%20thin%20and%20flexible%20design%2C%20able%20to%20improve%20the%20B1%2B%20field%20over%20each%20temporal%20lobe%20without%20deterioration%20of%20the%20RF%20performances%20in%20other%20brain%20areas%20and%20with%20minimal%20impact%20on%20patient%20comfort.%22%2C%22date%22%3A%22February%201%2C%202022%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.photonics.2021.100988%22%2C%22ISSN%22%3A%221569-4410%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fwww.sciencedirect.com%5C%2Fscience%5C%2Farticle%5C%2Fpii%5C%2FS156944102100095X%22%2C%22collections%22%3A%5B%2274RX9758%22%2C%22SK6VWU7K%22%2C%22KFAD7ZY5%22%2C%22BR9D2SS4%22%5D%2C%22dateModified%22%3A%222024-11-21T08%3A40%3A37Z%22%7D%7D%2C%7B%22key%22%3A%22YB2JI59E%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Jourdan%20et%20al.%22%2C%22parsedDate%22%3A%222022-01-29%22%2C%22numChildren%22%3A0%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BJourdan%2C%20A.%2C%20Rapacchi%2C%20S.%2C%20Guye%2C%20M.%2C%20Bendahan%2C%20D.%2C%20Masson%2C%20C.%20and%20B%26%23xE8%3Bge%2C%20T.%20%282022%29%20%26%23x201C%3BDynamic-MRI%20quantification%20of%20abdominal%20wall%20motion%20and%20deformation%20during%20breathing%20and%20muscular%20contraction%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BComputer%20Methods%20and%20Programs%20in%20Biomedicine%26lt%3B%5C%2Fi%26gt%3B%2C%20217%2C%20p.%20106667.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.cmpb.2022.106667%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.cmpb.2022.106667%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Dynamic-MRI%20quantification%20of%20abdominal%20wall%20motion%20and%20deformation%20during%20breathing%20and%20muscular%20contraction%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Arthur%22%2C%22lastName%22%3A%22Jourdan%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22David%22%2C%22lastName%22%3A%22Bendahan%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Catherine%22%2C%22lastName%22%3A%22Masson%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thierry%22%2C%22lastName%22%3A%22B%5Cu00e8ge%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%20AND%20OBJECTIVE%3A%20Biomechanical%20assessment%20of%20the%20abdominal%20wall%20represents%20a%20major%20prerequisite%20for%20a%20better%20understanding%20of%20physiological%20and%20pathological%20situations%20such%20as%20hernia%2C%20post-delivery%20recovery%2C%20muscle%20dystrophy%20or%20sarcopenia.%20Such%20an%20assessment%20is%20challenging%20and%20requires%20muscular%20deformations%20quantification%20which%20have%20been%20very%20scarcely%20reported%20in%20vivo.%20In%20the%20present%20study%2C%20we%20intended%20to%20characterize%20abdominal%20wall%20deformations%20in%20passive%20and%20active%20conditions%20using%20dynamic%20MRI%20combined%20to%20a%20semiautomatic%20segmentation%20procedure.%5CnMETHODS%3A%20Dynamic%20deformations%20resulting%20from%20three%20complementary%20exercises%20i.e.%20forced%20breathing%2C%20coughing%20and%20Valsalva%20maneuver%20were%20mapped%20in%20a%20transversal%20abdominal%20plane%20and%20so%20for%20twenty%20healthy%20volunteers.%20Real-time%20dynamic%20MRI%20series%20were%20acquired%20at%20a%20rate%20of%20182%5Cu00a0ms%20per%20image%2C%20then%20segmented%20semi-automatically%20to%20follow%20muscles%20deformation%20through%20each%20exercise.%20Circumferential%20and%20radial%20strains%20of%20each%20abdominal%20muscle%20were%20computed%20from%20the%20geometrical%20characteristics%26%23039%3B%20quantification%2C%20namely%20the%20medial%20axis%20length%20and%20the%20thickness.%20Muscular%20radial%20displacement%20maps%20were%20computed%20using%20image%20registration.%5CnRESULTS%3A%20Large%20variations%20in%20circumferential%20and%20radial%20strains%20were%20observed%20for%20the%20lateral%20muscles%20%28LM%29%20but%20remained%20low%20for%20the%20rectus%20abdominis%20muscles%20%28RA%29.%20Contraction%20phases%20of%20each%20exercise%20led%20to%20LM%20muscle%20shortening%20down%20to%20-9.6%5Cu00a0%5Cu00b1%5Cu00a05.9%25%20during%20Valsalva%20maneuver%20with%20a%2016.2%5Cu00a0%5Cu00b1%5Cu00a09.6%25%20thickness%20increase.%20Contraction%20also%20led%20to%20inward%20radial%20displacement%20of%20the%20LM%20up%20to%209.9%5Cu00a0%5Cu00b1%5Cu00a04.1%5Cu00a0mm%20during%20coughing.%20During%20maximal%20inhalation%2C%20a%20significant%2010.0%5Cu00a0%5Cu00b1%5Cu00a06.6%25%20lengthening%20was%20quantified%20for%20LM%20while%20a%20significant%20thickness%20decrease%20was%20computed%20for%20the%20whole%20set%20of%20muscles%20%28-14.7%5Cu00a0%5Cu00b1%5Cu00a06.6%25%20for%20LM%20and%20-7.3%5Cu00a0%5Cu00b1%5Cu00a06.5%25%20for%20RA%29.%20The%20largest%20displacement%20was%20observed%20for%20the%20medial%20part%20of%20RA%20%2817.9%5Cu00a0%5Cu00b1%5Cu00a08.0%5Cu00a0mm%29%20whereas%20the%20posterior%20part%20of%20LM%20underwent%20limited%20motion%20%282.8%5Cu00a0%5Cu00b1%5Cu00a02.3%5Cu00a0mm%29.%20Displacement%20rate%20and%20correlation%20between%20muscle%20thickness%20and%20medial%20axis%20length%20during%20each%20exercise%20provided%20insights%20regarding%20subject-specific%20muscle%20function.%5CnCONCLUSIONS%3A%20Dynamic%20MRI%20is%20a%20promising%20tool%20for%20the%20assessment%20of%20the%20abdominal%20wall%20motion%20and%20deformations.%20The%20corresponding%20metrics%20which%20have%20been%20continuously%20recorded%20during%20the%20exercises%20provided%20global%20and%20regional%20quantitative%20information.%20These%20metrics%20offer%20perspectives%20for%20a%20genuine%20clinical%20evaluation%20tool%20dedicated%20to%20the%20assessment%20of%20abdominal%20muscles%20function%20in%20both%20healthy%20subjects%20and%20patients.%22%2C%22date%22%3A%222022-01-29%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.cmpb.2022.106667%22%2C%22ISSN%22%3A%221872-7565%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22NW6SZQBR%22%2C%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222024-07-26T08%3A15%3A04Z%22%7D%7D%2C%7B%22key%22%3A%22G78AV2B4%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Daud%5Cu00e9%20et%20al.%22%2C%22parsedDate%22%3A%222022-01-06%22%2C%22numChildren%22%3A0%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BDaud%26%23xE9%3B%2C%20P.%2C%20Ancel%2C%20P.%2C%20Confort%20Gouny%2C%20S.%2C%20Jacquier%2C%20A.%2C%20Kober%2C%20F.%2C%20Dutour%2C%20A.%2C%20Bernard%2C%20M.%2C%20Gaborit%2C%20B.%20and%20Rapacchi%2C%20S.%20%282022%29%20%26%23x201C%3BDeep-Learning%20Segmentation%20of%20Epicardial%20Adipose%20Tissue%20Using%20Four-Chamber%20Cardiac%20Magnetic%20Resonance%20Imaging%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BDiagnostics%20%28Basel%2C%20Switzerland%29%26lt%3B%5C%2Fi%26gt%3B%2C%2012%281%29%2C%20p.%20126.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.3390%5C%2Fdiagnostics12010126%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.3390%5C%2Fdiagnostics12010126%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Deep-Learning%20Segmentation%20of%20Epicardial%20Adipose%20Tissue%20Using%20Four-Chamber%20Cardiac%20Magnetic%20Resonance%20Imaging%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Pierre%22%2C%22lastName%22%3A%22Daud%5Cu00e9%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Patricia%22%2C%22lastName%22%3A%22Ancel%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Sylviane%22%2C%22lastName%22%3A%22Confort%20Gouny%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alexis%22%2C%22lastName%22%3A%22Jacquier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%22%2C%22lastName%22%3A%22Kober%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Anne%22%2C%22lastName%22%3A%22Dutour%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Monique%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22B%5Cu00e9n%5Cu00e9dicte%22%2C%22lastName%22%3A%22Gaborit%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22In%20magnetic%20resonance%20imaging%20%28MRI%29%2C%20epicardial%20adipose%20tissue%20%28EAT%29%20overload%20remains%20often%20overlooked%20due%20to%20tedious%20manual%20contouring%20in%20images.%20Automated%20four-chamber%20EAT%20area%20quantification%20was%20proposed%2C%20leveraging%20deep-learning%20segmentation%20using%20multi-frame%20fully%20convolutional%20networks%20%28FCN%29.%20The%20investigation%20involved%20100%20subjects-comprising%20healthy%2C%20obese%2C%20and%20diabetic%20patients-who%20underwent%203T%20cardiac%20cine%20MRI%2C%20optimized%20U-Net%20and%20FCN%20%28noted%20FCNB%29%20were%20trained%20on%20three%20consecutive%20cine%20frames%20for%20segmentation%20of%20central%20frame%20using%20dice%20loss.%20Networks%20were%20trained%20using%204-fold%20cross-validation%20%28n%20%3D%2080%29%20and%20evaluated%20on%20an%20independent%20dataset%20%28n%20%3D%2020%29.%20Segmentation%20performances%20were%20compared%20to%20inter-intra%20observer%20bias%20with%20dice%20%28DSC%29%20and%20relative%20surface%20error%20%28RSE%29.%20Both%20systole%20and%20diastole%20four-chamber%20area%20were%20correlated%20with%20total%20EAT%20volume%20%28r%20%3D%200.77%20and%200.74%20respectively%29.%20Networks%26%23039%3B%20performances%20were%20equivalent%20to%20inter-observers%26%23039%3B%20bias%20%28EAT%3A%20DSCInter%20%3D%200.76%2C%20DSCU-Net%20%3D%200.77%2C%20DSCFCNB%20%3D%200.76%29.%20U-net%20outperformed%20%28p%20%26lt%3B%200.0001%29%20FCNB%20on%20all%20metrics.%20Eventually%2C%20proposed%20multi-frame%20U-Net%20provided%20automated%20EAT%20area%20quantification%20with%20a%2014.2%25%20precision%20for%20the%20clinically%20relevant%20upper%20three%20quarters%20of%20EAT%20area%20range%2C%20scaling%20patients%26%23039%3B%20risk%20of%20EAT%20overload%20with%2070%25%20accuracy.%20Exploiting%20multi-frame%20U-Net%20in%20standard%20cine%20provided%20automated%20EAT%20quantification%20over%20a%20wide%20range%20of%20EAT%20quantities.%20The%20method%20is%20made%20available%20to%20the%20community%20through%20a%20FSLeyes%20plugin.%22%2C%22date%22%3A%222022-01-06%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.3390%5C%2Fdiagnostics12010126%22%2C%22ISSN%22%3A%222075-4418%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%227JR7EDKF%22%2C%225Z6CVJGB%22%2C%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22ACGLJ26R%22%2C%22BR9D2SS4%22%5D%2C%22dateModified%22%3A%222024-12-05T16%3A12%3A37Z%22%7D%7D%2C%7B%22key%22%3A%2243Y2GSMR%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Rapacchi%20et%20al.%22%2C%22parsedDate%22%3A%222022%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BRapacchi%2C%20S.%2C%20Viallon%2C%20M.%20and%20Croisille%2C%20P.%20%282022%29%20%26%23x201C%3BEditorial%20for%20%26%23x2018%3BImpact%20of%20Temporal%20Resolution%20and%20Methods%20for%20Correction%20on%20Cardiovascular%20Magnetic%20Resonance%20Perfusion%20Quantification%2C%26%23x2019%3B%26%23x201D%3B%20%26lt%3Bi%26gt%3BJournal%20of%20Magnetic%20Resonance%20Imaging%26lt%3B%5C%2Fi%26gt%3B%2C%2056%286%29%2C%20pp.%201720%26%23x2013%3B1721.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fjmri.28402%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fjmri.28402%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Editorial%20for%20%5Cu201cImpact%20of%20Temporal%20Resolution%20and%20Methods%20for%20Correction%20on%20Cardiovascular%20Magnetic%20Resonance%20Perfusion%20Quantification%5Cu201d%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Magalie%22%2C%22lastName%22%3A%22Viallon%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Pierre%22%2C%22lastName%22%3A%22Croisille%22%7D%5D%2C%22abstractNote%22%3A%22%22%2C%22date%22%3A%222022%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1002%5C%2Fjmri.28402%22%2C%22ISSN%22%3A%221522-2586%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fonlinelibrary.wiley.com%5C%2Fdoi%5C%2Fabs%5C%2F10.1002%5C%2Fjmri.28402%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222023-11-23T10%3A41%3A28Z%22%7D%7D%2C%7B%22key%22%3A%22UAZ9C9KH%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Brui%20et%20al.%22%2C%22parsedDate%22%3A%222021-12-01%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BBrui%2C%20E.A.%2C%20Rapacchi%2C%20S.%2C%20Bendahan%2C%20D.%20and%20Andreychenko%2C%20A.E.%20%282021%29%20%26%23x201C%3BComparative%20analysis%20of%20SINC-shaped%20and%20SLR%20pulses%20performance%20for%20contiguous%20multi-slice%20fast%20spin-echo%20imaging%20using%20metamaterial-based%20MRI%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20Materials%20in%20Physics%2C%20Biology%20and%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2034%286%29%2C%20pp.%20929%26%23x2013%3B938.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-ItemURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1007%5C%2Fs10334-021-00937-w%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1007%5C%2Fs10334-021-00937-w%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Comparative%20analysis%20of%20SINC-shaped%20and%20SLR%20pulses%20performance%20for%20contiguous%20multi-slice%20fast%20spin-echo%20imaging%20using%20metamaterial-based%20MRI%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ekaterina%20A.%22%2C%22lastName%22%3A%22Brui%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22David%22%2C%22lastName%22%3A%22Bendahan%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Anna%20E.%22%2C%22lastName%22%3A%22Andreychenko%22%7D%5D%2C%22abstractNote%22%3A%22To%20comparatively%20assess%20the%20performance%20of%20highly%20selective%20pulses%20computed%20with%20the%20SLR%20algorithm%20in%20fast-spin%20echo%20%28FSE%29%20within%20the%20current%20radiofrequency%20safety%20limits%20using%20a%20metamaterial-based%20coil%20for%20wrist%20magnetic%20resonance%20imaging.%22%2C%22date%22%3A%222021-12-01%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1007%5C%2Fs10334-021-00937-w%22%2C%22ISSN%22%3A%221352-8661%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1007%5C%2Fs10334-021-00937-w%22%2C%22collections%22%3A%5B%22NW6SZQBR%22%2C%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222025-03-19T13%3A33%3A17Z%22%7D%7D%2C%7B%22key%22%3A%226XIU34DQ%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Sourdon%20et%20al.%22%2C%22parsedDate%22%3A%222021-05-13%22%2C%22numChildren%22%3A0%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BSourdon%2C%20J.%2C%20Roussel%2C%20T.%2C%20Costes%2C%20C.%2C%20Viout%2C%20P.%2C%20Guye%2C%20M.%2C%20Ranjeva%2C%20J.-P.%2C%20Bernard%2C%20M.%2C%20Kober%2C%20F.%20and%20Rapacchi%2C%20S.%20%282021%29%20%26%23x201C%3BComparison%20of%20single-voxel%201H-cardiovascular%20magnetic%20resonance%20spectroscopy%20techniques%20for%20in%20vivo%20measurement%20of%20myocardial%20creatine%20and%20triglycerides%20at%203T%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BJournal%20of%20Cardiovascular%20Magnetic%20Resonance%3A%20Official%20Journal%20of%20the%20Society%20for%20Cardiovascular%20Magnetic%20Resonance%26lt%3B%5C%2Fi%26gt%3B%2C%2023%281%29%2C%20p.%2053.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1186%5C%2Fs12968-021-00748-x%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1186%5C%2Fs12968-021-00748-x%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Comparison%20of%20single-voxel%201H-cardiovascular%20magnetic%20resonance%20spectroscopy%20techniques%20for%20in%20vivo%20measurement%20of%20myocardial%20creatine%20and%20triglycerides%20at%203T%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Joevin%22%2C%22lastName%22%3A%22Sourdon%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Tangi%22%2C%22lastName%22%3A%22Roussel%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Claire%22%2C%22lastName%22%3A%22Costes%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Patrick%22%2C%22lastName%22%3A%22Viout%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jean-Philippe%22%2C%22lastName%22%3A%22Ranjeva%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Monique%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%22%2C%22lastName%22%3A%22Kober%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%3A%20Single-voxel%20proton%20cardiovascular%20magnetic%20resonance%20spectroscopy%20%281H-CMRS%29%20benefits%20from%203%5Cu00a0T%20to%20detect%20metabolic%20abnormalities%20with%20the%20quantification%20of%20intramyocardial%20fatty%20acids%20%28FA%29%20and%20creatine%20%28Cr%29.%20Conventional%20point%20resolved%20spectroscopy%20%28PRESS%29%20sequence%20remains%20the%20preferred%20choice%20for%20CMRS%2C%20despite%20its%20chemical%20shift%20displacement%20error%20%28CSDE%29%20at%20high%20field%20%28%5Cu2265%5Cu20093%5Cu00a0T%29.%20Alternative%20candidate%20sequences%20are%20the%20semi-adiabatic%20Localization%20by%20Adiabatic%20SElective%20Refocusing%20%28sLASER%29%20recommended%20for%20brain%20and%20musculoskeletal%20applications%20and%20the%20localized%20stimulated%20echo%20acquisition%20mode%20%28STEAM%29.%20In%20this%20study%2C%20we%20aim%20to%20compare%20these%20three%20single-voxel%201H-CMRS%20techniques%3A%20PRESS%2C%20sLASER%20and%20STEAM%20for%20reproducible%20quantification%20of%20myocardial%20FA%20and%20Cr%20at%203%5Cu00a0T.%20Sequences%20are%20compared%20both%20using%20breath-hold%20%28BH%29%20and%20free-breathing%20%28FB%29%20acquisitions.%5CnMETHODS%3A%20CMRS%20accuracy%20and%20theoretical%20CSDE%20were%20verified%20on%20a%20purposely-designed%20fat-water%20phantom.%20FA%20and%20Cr%20CMRS%20data%20quality%20and%20reliability%20were%20evaluated%20in%20the%20interventricular%20septum%20of%2010%20healthy%20subjects%2C%20comparing%20repeated%20BH%20and%20free-breathing%20with%20retrospective%20gating.%5CnRESULTS%3A%20Measured%20FA%5C%2FW%20ratio%20deviated%20from%20expected%20phantom%20ratio%20due%20to%20CSDE%20with%20all%20sequences.%20sLASER%20supplied%20the%20lowest%20bias%20%2810%25%2C%20vs%20-28%25%20and%2027%25%20for%20PRESS%20and%20STEAM%29.%20In%20vivo%2C%20PRESS%20provided%20the%20highest%20signal-to-noise%20ratio%20%28SNR%29%20in%20FB%20scans%20%2827.5%20for%20Cr%20and%20103.2%20for%20FA%29.%20Nevertheless%2C%20a%20linear%20regression%20analysis%20between%20the%20two%20BH%20showed%20a%20better%20correlation%20between%20myocardial%20Cr%20content%20measured%20with%20sLASER%20compared%20to%20PRESS%20%28r%5Cu2009%3D%5Cu20090.46%3B%20p%5Cu2009%3D%5Cu20090.03%20vs.%20r%5Cu2009%3D%5Cu20090.35%3B%20p%5Cu2009%3D%5Cu20090.07%29%20and%20similar%20slopes%20of%20regression%20lines%20for%20FA%20measurements%20%28r%5Cu2009%3D%5Cu20090.94%3B%20p%5Cu2009%26lt%3B%5Cu20090.001%20vs.%20r%5Cu2009%3D%5Cu20090.87%3B%20p%5Cu2009%26lt%3B%5Cu20090.001%29.%20STEAM%20was%20unable%20to%20perform%20Cr%20measurement%20and%20was%20the%20method%20with%20the%20lowest%20correlation%20%28r%5Cu2009%3D%5Cu20090.59%3B%20p%5Cu2009%3D%5Cu20090.07%29%20for%20FA.%20No%20difference%20was%20found%20between%20measurements%20done%20either%20during%20BH%20or%20FB%20for%20Cr%2C%20FA%20and%20triglycerides%20using%20PRESS%2C%20sLASER%20and%20STEAM.%5CnCONCLUSION%3A%20When%20quantifying%20myocardial%20lipids%20and%20creatine%20with%20CMR%20proton%5Cu00a0spectroscopy%20at%203%5Cu00a0T%2C%20PRESS%20provided%20higher%20SNR%2C%20while%20sLASER%20was%20more%20reproducible%20both%20with%20single%20BH%20and%20FB%20scans.%22%2C%22date%22%3A%222021-05-13%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1186%5C%2Fs12968-021-00748-x%22%2C%22ISSN%22%3A%221532-429X%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%225Z6CVJGB%22%2C%22QU2QXBVV%22%2C%22UP3H3ICX%22%2C%22SK6VWU7K%22%2C%226B37I9FA%22%2C%22XTA6KS7L%22%2C%22BR9D2SS4%22%5D%2C%22dateModified%22%3A%222023-12-15T10%3A47%3A35Z%22%7D%7D%2C%7B%22key%22%3A%22RYX65CG9%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Gaborit%20et%20al.%22%2C%22parsedDate%22%3A%222021-03-01%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BGaborit%2C%20B.%2C%20Ancel%2C%20P.%2C%20Abdullah%2C%20A.E.%2C%20Maurice%2C%20F.%2C%20Abdesselam%2C%20I.%2C%20Calen%2C%20A.%2C%20Soghomonian%2C%20A.%2C%20Houssays%2C%20M.%2C%20Varlet%2C%20I.%2C%20Eisinger%2C%20M.%2C%20Lasbleiz%2C%20A.%2C%20Peiretti%2C%20F.%2C%20Bornet%2C%20C.E.%2C%20Lefur%2C%20Y.%2C%20Pini%2C%20L.%2C%20Rapacchi%2C%20S.%2C%20Bernard%2C%20M.%2C%20Resseguier%2C%20N.%2C%20Darmon%2C%20P.%2C%20Kober%2C%20F.%20and%20Dutour%2C%20A.%20%282021%29%20%26%23x201C%3BEffect%20of%20empagliflozin%20on%20ectopic%20fat%20stores%20and%20myocardial%20energetics%20in%20type%202%20diabetes%3A%20the%20EMPACEF%20study%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BCardiovascular%20Diabetology%26lt%3B%5C%2Fi%26gt%3B%2C%2020%281%29%2C%20p.%2057.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1186%5C%2Fs12933-021-01237-2%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1186%5C%2Fs12933-021-01237-2%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Effect%20of%20empagliflozin%20on%20ectopic%20fat%20stores%20and%20myocardial%20energetics%20in%20type%202%20diabetes%3A%20the%20EMPACEF%20study%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22B.%22%2C%22lastName%22%3A%22Gaborit%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22P.%22%2C%22lastName%22%3A%22Ancel%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%20E.%22%2C%22lastName%22%3A%22Abdullah%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22F.%22%2C%22lastName%22%3A%22Maurice%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22I.%22%2C%22lastName%22%3A%22Abdesselam%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Calen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Soghomonian%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Houssays%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22I.%22%2C%22lastName%22%3A%22Varlet%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Eisinger%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Lasbleiz%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22F.%22%2C%22lastName%22%3A%22Peiretti%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22C.%20E.%22%2C%22lastName%22%3A%22Bornet%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Y.%22%2C%22lastName%22%3A%22Lefur%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22L.%22%2C%22lastName%22%3A%22Pini%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22S.%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22N.%22%2C%22lastName%22%3A%22Resseguier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22P.%22%2C%22lastName%22%3A%22Darmon%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22F.%22%2C%22lastName%22%3A%22Kober%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Dutour%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%3A%20Empagliflozin%20is%20a%20sodium-glucose%20cotransporter%202%20%28SGLT2%29%20inhibitor%20that%20has%20demonstrated%20cardiovascular%20and%20renal%20protection%20in%20patients%20with%20type%202%20diabetes%20%28T2D%29.%20We%20hypothesized%20that%20empaglifozin%20%28EMPA%29%20could%20modulate%20ectopic%20fat%20stores%20and%20myocardial%20energetics%20in%20high-fat-high-sucrose%20%28HFHS%29%20diet%20mice%20and%20in%20type%202%20diabetics%20%28T2D%29.%5CnMETHODS%3A%20C57BL%5C%2F6%20HFHS%20mice%20%28n%5Cu2009%3D%5Cu200924%29%20and%20T2D%20subjects%20%28n%5Cu2009%3D%5Cu200956%29%20were%20randomly%20assigned%20to%2012%5Cu00a0weeks%20of%20treatment%20with%20EMPA%20%2830%5Cu00a0mg%5C%2Fkg%20in%20mice%2C%2010%5Cu00a0mg%5C%2Fday%20in%20humans%29%20or%20with%20placebo.%20A%204.7%5Cu00a0T%20or%203%5Cu00a0T%20MRI%20with%201H-MRS%20evaluation-myocardial%20fat%20%28primary%20endpoint%29%20and%20liver%20fat%20content%20%28LFC%29-were%20performed%20at%20baseline%20and%20at%2012%5Cu00a0weeks.%20In%20humans%2C%20standard%20cardiac%20MRI%20was%20coupled%20with%20myocardial%20energetics%20%28PCr%5C%2FATP%29%20measured%20with%2031P-MRS.%20Subcutaneous%20%28SAT%29%20abdominal%2C%20visceral%20%28VAT%29%2C%20epicardial%20and%20pancreatic%20fat%20were%20also%20evaluated.%20The%20primary%20efficacy%20endpoint%20was%20the%20change%20in%20epicardial%20fat%20volume%20between%20EMPA%20and%20placebo%20from%20baseline%20to%2012%5Cu00a0weeks.%20Secondary%20endpoints%20were%20the%20differences%20in%20PCr%5C%2FATP%20ratio%2C%20myocardial%2C%20liver%20and%20pancreatic%20fat%20content%2C%20SAT%20and%20VAT%20between%20groups%20at%2012%5Cu00a0weeks.%5CnRESULTS%3A%20In%20mice%20fed%20HFHS%2C%20EMPA%20significantly%20improved%20glucose%20tolerance%20and%20increased%20blood%20ketone%20bodies%20%28KB%29%20and%20%5Cu03b2-hydroxybutyrate%20levels%20%28p%5Cu2009%26lt%3B%5Cu20090.05%29%20compared%20to%20placebo.%20Mice%20fed%20HFHS%20had%20increased%20myocardial%20and%20liver%20fat%20content%20compared%20to%20standard%20diet%20mice.%20EMPA%20significantly%20attenuated%20liver%20fat%20content%20by%2055%25%2C%20%28p%5Cu2009%26lt%3B%5Cu20090.001%29%20but%20had%20no%20effect%20on%20myocardial%20fat.%20In%20the%20human%20study%2C%20all%20the%2056%20patients%20had%20normal%20LV%20function%20with%20mean%20LVEF%5Cu2009%3D%5Cu200963.4%5Cu2009%5Cu00b1%5Cu20097.9%25.%20Compared%20to%20placebo%2C%20T2D%20patients%20treated%20with%20EMPA%20significantly%20lost%20weight%20%28-%5Cu20092.6%5Cu00a0kg%20%5B-%5Cu20091.2%3B%5Cu2009-%5Cu20093.7%5D%29%20and%20improved%20their%20HbA1c%20by%200.88%5Cu2009%5Cu00b1%5Cu20090.74%25.%20Hematocrit%20and%20EPO%20levels%20were%20significantly%20increased%20in%20the%20EMPA%20group%20compared%20to%20placebo%20%28p%5Cu2009%26lt%3B%5Cu20090.0001%2C%20p%5Cu2009%3D%5Cu20090.041%29.%20EMPA%20significantly%20increased%20glycosuria%20and%20plasma%20KB%20levels%20compared%20to%20placebo%20%28p%5Cu2009%26lt%3B%5Cu20090.0001%2C%20p%5Cu2009%3D%5Cu20090.012%2C%20respectively%29%2C%20and%20significantly%20reduced%20liver%20fat%20content%20%28-%5Cu200927%5Cu2009%5Cu00b1%5Cu200923%5Cu00a0vs.%5Cu2009-%5Cu20092%5Cu2009%5Cu00b1%5Cu200924%25%2C%20p%5Cu2009%3D%5Cu20090.0005%29%20and%20visceral%20fat%20%28-%5Cu20097.8%25%20%5B-%5Cu200915.3%3B%5Cu2009-%5Cu20095.6%5D%20vs.%5Cu2009-%5Cu20090.1%25%20%5B-%5Cu20091.1%3B6.5%5D%2C%20p%5Cu2009%3D%5Cu20090.043%29%2C%20but%20had%20no%20effect%20on%20myocardial%20or%20epicardial%20fat.%20At%2012%5Cu00a0weeks%2C%20no%20significant%20change%20was%20observed%20in%20the%20myocardial%20PCr%5C%2FATP%20%28p%5Cu2009%3D%5Cu20090.57%20between%20groups%29.%5CnCONCLUSIONS%3A%20EMPA%20effectively%20reduced%20liver%20fat%20in%20mice%20and%20humans%20without%20changing%20epicardial%2C%20myocardial%20fat%20or%20myocardial%20energetics%2C%20rebutting%20the%20thrifty%20substrate%20hypothesis%20for%20cardiovascular%20protection%20of%20SGLT2%20inhibitors.%20Trial%20registration%20NCT%2C%20NCT03118336.%20Registered%2018%20April%202017%2C%20https%3A%5C%2F%5C%2Fclinicaltrials.gov%5C%2Fct2%5C%2Fshow%5C%2FNCT03118336.%22%2C%22date%22%3A%222021-03-01%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1186%5C%2Fs12933-021-01237-2%22%2C%22ISSN%22%3A%221475-2840%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SVI8UJ6H%22%2C%225Z6CVJGB%22%2C%22SK6VWU7K%22%2C%22BR9D2SS4%22%5D%2C%22dateModified%22%3A%222024-10-15T14%3A45%3A08Z%22%7D%7D%2C%7B%22key%22%3A%22H5NLZLCE%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Foussier%20et%20al.%22%2C%22parsedDate%22%3A%222021-03%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BFoussier%2C%20C.%2C%20Barral%2C%20P.A.%2C%20Jerosh-Herold%2C%20M.%2C%20Gariboldi%2C%20V.%2C%20Rapacchi%2C%20S.%2C%20Gallon%2C%20A.%2C%20Bartoli%2C%20A.%2C%20Bentatou%2C%20Z.%2C%20Guye%2C%20M.%2C%20Bernard%2C%20M.%20and%20Jacquier%2C%20A.%20%282021%29%20%26%23x201C%3BQuantification%20of%20diffuse%20myocardial%20fibrosis%20using%20CMR%20extracellular%20volume%20fraction%20and%20serum%20biomarkers%20of%20collagen%20turnover%20with%20histologic%20quantification%20as%20standard%20of%20reference%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BDiagnostic%20and%20Interventional%20Imaging%26lt%3B%5C%2Fi%26gt%3B%2C%20102%283%29%2C%20pp.%20163%26%23x2013%3B169.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.diii.2020.07.005%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.diii.2020.07.005%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Quantification%20of%20diffuse%20myocardial%20fibrosis%20using%20CMR%20extracellular%20volume%20fraction%20and%20serum%20biomarkers%20of%20collagen%20turnover%20with%20histologic%20quantification%20as%20standard%20of%20reference%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22C.%22%2C%22lastName%22%3A%22Foussier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22P.%20A.%22%2C%22lastName%22%3A%22Barral%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Jerosh-Herold%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22V.%22%2C%22lastName%22%3A%22Gariboldi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22S.%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Gallon%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Bartoli%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Z.%22%2C%22lastName%22%3A%22Bentatou%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Jacquier%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20compare%20the%20assessment%20of%20diffuse%20interstitial%20myocardial%20fibrosis%20in%20valvular%20diseases%20using%20cardiac%20magnetic%20resonance%20%28CMR%29%20extracellular%20volume%20fraction%20%28ECV%29%20quantification%20and%20serum%20biomarkers%20of%20collagen%20turnover%20using%20results%20of%20myocardial%20biopsy%20as%20standard%20of%20reference.%5CnMATERIALS%20AND%20METHODS%3A%20This%20prospective%20monocentric%20study%20included%20consecutive%20patients%20before%20aortic%20valvular%20replacement.%20All%20patients%20underwent%3A%20i%29%2C%201.5T%20CMR%20with%20pre%20and%20post%20contrast%20T1%20mapping%20sequence%20and%20ECV%20computation%3B%20ii%29%2C%20serum%20quantification%20of%20matrix%20metalloproteinases%20%28MMPs%29%20and%20tissue%20inhibitor%20of%20metalloproteinases%20%28TIMPs%29%20and%20iii%29%2C%20myocardial%20biopsies%20were%20collected%20during%20surgery%20to%20assess%20collagen%20volume%20fraction%20%28CVF%29.%20Patients%20with%20coronary%20artery%20disease%20were%20excluded.%20Correlation%20between%20native%20T1%2C%20ECV%2C%20CVF%20and%20serum%20biomarkers%20were%20assessed%20using%20Pearson%20correlation%20test.%20Agreement%20between%20basal%20anteroseptal%20ECV%20with%20global%20ECV%20was%20assessed%20using%20Bland-Altman%20test.%5CnRESULTS%3A%20Twenty-one%20patients%2C%2016%20with%20aortic%20stenosis%20and%205%20with%20aortic%20regurgitation%20were%20included.%20There%20were%2012%20men%20and%209%20women%20with%20a%20mean%20age%20of%2074.1%5Cu00b16.8%20%28SD%29%20years%20%28range%3A%2032-84%20years%29.%20Mean%20global%20ECV%20value%20was%2026.7%5Cu00b12.7%20%28SD%29%20%25%20%28range%3A%2023.4-32.5%25%29%20and%20mean%20CVF%20value%20was%2012.4%5Cu00b19.7%25%20%28range%3A%203.2-25.7%25%29.%20ECV%20assessed%20at%20the%20basal%20anteroseptal%20segment%20correlated%20moderately%20with%20CVF%20%28r%3D0.6%3B%20P%3D0.0026%29.%20There%20was%20a%20strong%20correlation%20and%20agreement%20between%20basal%20anteroseptal%20ECV%20and%20global%20ECV%2C%20%28r%3D0.8%3B%20P%26lt%3B0.0001%3B%20bias%205.4%5Cu00b16.1%25%29%20but%20no%20correlation%20between%20global%20ECV%20and%20CVF%20%28r%3D0.5%3B%20P%3D0.10%29.%20Global%20ECV%20poorly%20correlated%20with%20serum%20TIMP-1%20%28r%3D0.4%3B%20P%3D0.037%29%20and%20MMP-2%20%28r%3D0.4%3B%20P%3D0.047%29.%20No%20correlation%20was%20found%20between%20serum%20biomarkers%20and%20basal%20anteroseptal-%20ECV%20or%20native%20T1.%5CnCONCLUSION%3A%20In%20patients%20with%20severe%20aortic%20valvulopathy%2C%20diffuse%20myocardial%20fibrosis%20assessed%20by%20anterosepto-basal%20ECV%20correlates%20with%20histological%20myocardial%20fibrosis.%20Anteroseptobasal%20ECV%20strongly%20correlates%20with%20global%20ECV%2C%20which%20poorly%20correlates%20with%20TIMP-1%20and%20MMP-2%2C%20serum%20biomarkers%20involved%20in%20the%20progression%20of%20heart%20failure.%22%2C%22date%22%3A%222021-03%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.diii.2020.07.005%22%2C%22ISSN%22%3A%222211-5684%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%225Z6CVJGB%22%2C%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22B4FUISBZ%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222025-11-28T09%3A19%3A37Z%22%7D%7D%2C%7B%22key%22%3A%227R6WI53A%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Jourdan%20et%20al.%22%2C%22parsedDate%22%3A%222021%22%2C%22numChildren%22%3A4%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BJourdan%2C%20A.%2C%20Le%20Troter%2C%20A.%2C%20Daude%2C%20P.%2C%20Rapacchi%2C%20S.%2C%20Masson%2C%20C.%2C%20B%26%23xE8%3Bge%2C%20T.%20and%20Bendahan%2C%20D.%20%282021%29%20%26%23x201C%3BSemiautomatic%20quantification%20of%20abdominal%20wall%20muscles%20deformations%20based%20on%20dynamic%20MRI%20image%20registration%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BNMR%20in%20Biomedicine%26lt%3B%5C%2Fi%26gt%3B%2C%2034%284%29%2C%20p.%20e4470.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fnbm.4470%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fnbm.4470%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Semiautomatic%20quantification%20of%20abdominal%20wall%20muscles%20deformations%20based%20on%20dynamic%20MRI%20image%20registration%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Arthur%22%2C%22lastName%22%3A%22Jourdan%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Arnaud%22%2C%22lastName%22%3A%22Le%20Troter%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Pierre%22%2C%22lastName%22%3A%22Daude%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Catherine%22%2C%22lastName%22%3A%22Masson%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thierry%22%2C%22lastName%22%3A%22B%5Cu00e8ge%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22David%22%2C%22lastName%22%3A%22Bendahan%22%7D%5D%2C%22abstractNote%22%3A%22Quantitative%20analysis%20of%20abdominal%20organs%20motion%20and%20deformation%20is%20crucial%20to%20better%20understand%20biomechanical%20alterations%20undermining%20respiratory%2C%20digestive%20or%20perineal%20pathophysiology.%20In%20particular%2C%20biomechanical%20characterization%20of%20the%20antero-lateral%20abdominal%20wall%20is%20central%20in%20the%20diagnosis%20of%20abdominal%20muscle%20deficiency.%20Here%2C%20we%20present%20a%20dedicated%20semiautomatic%20dynamic%20MRI%20postprocessing%20method%20enabling%20the%20quantification%20of%20spatial%20and%20temporal%20deformations%20of%20the%20antero-lateral%20abdominal%20wall%20muscles.%20Ten%20healthy%20participants%20were%20imaged%20during%20a%20controlled%20breathing%20session%20at%20the%20L3%5Cu2013L4%20disc%20level%20using%20real-time%20dynamic%20MRI%20at%203%20T.%20A%20coarse%20feature-tracking%20step%20allowed%20the%20selection%20of%20the%20inhalation%20cycle%20of%20maximum%20abdominal%20excursion.%20Over%20this%20image%20series%2C%20the%20described%20method%20combines%20%281%29%20a%20supervised%202D%2Bt%20segmentation%20procedure%20of%20the%20abdominal%20wall%20muscles%2C%20%282%29%20the%20quantification%20of%20muscle%20deformations%20based%20on%20masks%20registration%2C%20and%20%283%29%20the%20mapping%20of%20deformations%20within%20muscle%20subzones%20leveraging%20a%20dedicated%20automatic%20parcellation.%20The%20supervised%202D%2Bt%20segmentation%20%281%29%20provided%20an%20accurate%20segmentation%20of%20the%20abdominal%20wall%20muscles%20throughout%20maximum%20inhalation%20with%20a%200.95%20%5Cu00b1%200.03%20Dice%20similarity%20coefficient%20%28DSC%29%20value%20and%20a%202.3%20%5Cu00b1%200.7%20mm%20Hausdorff%20distance%20value%20while%20requiring%20only%20manual%20segmentation%20of%2020%25%20of%20the%20data.%20The%20robustness%20of%20the%20deformation%20quantification%20%282%29%20was%20indicated%20by%20high%20indices%20of%20correspondence%20between%20the%20registered%20source%20mask%20and%20the%20target%20mask%20%280.98%20%5Cu00b1%200.01%20DSC%20value%20and%202.1%20%5Cu00b1%201.5%20mm%20Hausdorff%20distance%20value%29.%20Parcellation%20%283%29%20enabled%20the%20distinction%20of%20muscle%20substructures%20that%20are%20anatomically%20relevant%20but%20could%20not%20be%20distinguished%20based%20on%20image%20contrast.%20The%20present%20genuine%20postprocessing%20method%20provides%20a%20quantitative%20analytical%20frame%20that%20could%20be%20used%20in%20further%20studies%20for%20a%20better%20understanding%20of%20abdominal%20wall%20deformations%20in%20physiological%20and%20pathological%20situations.%22%2C%22date%22%3A%222021%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1002%5C%2Fnbm.4470%22%2C%22ISSN%22%3A%221099-1492%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fonlinelibrary.wiley.com%5C%2Fdoi%5C%2Fabs%5C%2F10.1002%5C%2Fnbm.4470%22%2C%22collections%22%3A%5B%22NW6SZQBR%22%2C%22SK6VWU7K%22%2C%225P5FWCR9%22%2C%22ACGLJ26R%22%5D%2C%22dateModified%22%3A%222024-12-05T16%3A12%3A37Z%22%7D%7D%2C%7B%22key%22%3A%22J4DJYSIJ%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Rapacchi%20and%20Gaborit%22%2C%22parsedDate%22%3A%222021%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BRapacchi%2C%20S.%20and%20Gaborit%2C%20B.%20%282021%29%20%26%23x201C%3BEditorial%20for%20%26%23x2018%3BAssociation%20of%20Type%202%20Diabetes%20Mellitus%20and%20Glycemic%20Control%20With%20Intracranial%20Plaque%20Characteristics%20in%20Patients%20With%20Acute%20Ischemic%20Stroke%2C%26%23x2019%3B%26%23x201D%3B%20%26lt%3Bi%26gt%3BJournal%20of%20Magnetic%20Resonance%20Imaging%26lt%3B%5C%2Fi%26gt%3B%2C%2054%282%29%2C%20pp.%20667%26%23x2013%3B668.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fjmri.27739%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fjmri.27739%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Editorial%20for%20%5Cu201cAssociation%20of%20Type%202%20Diabetes%20Mellitus%20and%20Glycemic%20Control%20With%20Intracranial%20Plaque%20Characteristics%20in%20Patients%20With%20Acute%20Ischemic%20Stroke%5Cu201d%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22B%5Cu00e9n%5Cu00e9dicte%22%2C%22lastName%22%3A%22Gaborit%22%7D%5D%2C%22abstractNote%22%3A%22%22%2C%22date%22%3A%222021%22%2C%22language%22%3A%22en%22%2C%22DOI%22%3A%2210.1002%5C%2Fjmri.27739%22%2C%22ISSN%22%3A%221522-2586%22%2C%22url%22%3A%22https%3A%5C%2F%5C%2Fonlinelibrary.wiley.com%5C%2Fdoi%5C%2Fabs%5C%2F10.1002%5C%2Fjmri.27739%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222024-10-15T14%3A45%3A06Z%22%7D%7D%2C%7B%22key%22%3A%22QPURJWXZ%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Hoesl%20et%20al.%22%2C%22parsedDate%22%3A%222020-11%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BHoesl%2C%20M.A.U.%2C%20Schad%2C%20L.R.%20and%20Rapacchi%2C%20S.%20%282020%29%20%26%23x201C%3BEfficient%2023%20Na%20triple-quantum%20signal%20imaging%20on%20clinical%20scanners%3A%20Cartesian%20imaging%20of%20single%20and%20triple-quantum%2023%20Na%20%28CRISTINA%29%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2084%285%29%2C%20pp.%202412%26%23x2013%3B2428.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.28284%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.28284%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Efficient%2023%20Na%20triple-quantum%20signal%20imaging%20on%20clinical%20scanners%3A%20Cartesian%20imaging%20of%20single%20and%20triple-quantum%2023%20Na%20%28CRISTINA%29%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Michaela%20A.%20U.%22%2C%22lastName%22%3A%22Hoesl%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lothar%20R.%22%2C%22lastName%22%3A%22Schad%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20capture%20the%20multiquantum%20coherence%20%28MQC%29%2023%20Na%20signal.%20Different%20phase-cycling%20options%20and%20sequences%20are%20compared%20in%20a%20unified%20theoretical%20layout%2C%20and%20a%20novel%20sequence%20is%20developed.%5CnMETHODS%3A%20An%20open%20source%20simulation%20overview%20is%20provided%20with%20graphical%20explanations%20to%20facilitate%20MQC%20understanding%20and%20access%20to%20techniques.%20Biases%20such%20as%20B0%20inhomogeneity%20and%20stimulated%20echo%20signal%20were%20simulated%20for%204%20different%20phase-cycling%20options%20previously%20described.%20Considerations%20for%20efficiency%20and%20accuracy%20lead%20to%20the%20implementation%20of%20a%202D%20Cartesian%20single%20and%20triple%20quantum%20imaging%20of%20sodium%20%28CRISTINA%29%20sequence%20employing%20two%206-step%20cycles%20in%20combination%20with%20a%20multi-echo%20readout.%20CRISTINA%20was%20compared%20to%20simultaneous%20single-quantum%20and%20triple-quantum-filtered%20MRI%20of%20sodium%20%28SISTINA%29%20under%20strong%20static%20magnetic%20gradient.%20CRISTINA%20capabilities%20were%20assessed%20on%208%5Cu00a0%5Cu00d7%5Cu00a060%5Cu00a0mL%2C%200%25%20to%205%25%20agarose%20phantom%20with%2050%20to%20154%5Cu00a0mM%2023%20Na%20concentration%20at%207%20T.%20CRISTINA%20was%20demonstrated%20subsequently%20in%20vivo%20in%20the%20brain.%5CnRESULTS%3A%20Simulation%20of%20B0%20inhomogeneity%20showed%20severe%20signal%20dropout%2C%20which%20can%20lead%20to%20erroneous%20MQC%20measurement.%20Stimulated%20echo%20signal%20was%20highest%20at%20the%20time%20of%20triple-quantum%20coherences%20signal%20maximum.%20However%2C%20stimulated%20echo%20signal%20is%20separated%20by%20Fourier%20Transform%20as%20an%20offset%20and%20did%20not%20interfere%20with%20MQC%20signals.%20The%20multi-echo%20readout%20enabled%20capturing%20both%20single-quantum%20coherences%20and%20triple-quantum%20coherences%20signal%20evolution%20at%20once.%20Signal%20combination%20of%202%20phase-cycles%20with%20a%20corresponding%20B0%20map%20was%20found%20to%20recover%20the%20signal%20optimally.%20Experimental%20results%20confirm%20and%20complement%20the%20simulations.%5CnCONCLUSION%3A%20Considerations%20for%20efficient%20MQC%20measurements%2C%20most%20importantly%20avoiding%20B0%20signal%20loss%2C%20led%20to%20the%20design%20of%20CRISTINA.%20CRISTINA%20captures%20triple-quantum%20coherences%20and%20single-quantum%20coherences%20signal%20evolution%20to%20provide%20complete%20sodium%20signal%20characterization%20including%20%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20T%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%202%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%5Cu2217%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20fast%2C%20%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20T%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%202%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%5Cu2217%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%5Cn%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20%20slow%2C%20MQC%20amplitudes%2C%20and%20sodium%20concentration.%22%2C%22date%22%3A%22Nov%202020%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.28284%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222022-02-24T14%3A35%3A46Z%22%7D%7D%2C%7B%22key%22%3A%2269GMLRSP%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22L%5Cu00e9vy%20et%20al.%22%2C%22parsedDate%22%3A%222020-09%22%2C%22numChildren%22%3A3%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BL%26%23xE9%3Bvy%2C%20S.%2C%20Rapacchi%2C%20S.%2C%20Massire%2C%20A.%2C%20Troalen%2C%20T.%2C%20Feiweier%2C%20T.%2C%20Guye%2C%20M.%20and%20Callot%2C%20V.%20%282020%29%20%26%23x201C%3BIntravoxel%20Incoherent%20Motion%20at%207%20Tesla%20to%20quantify%20human%20spinal%20cord%20perfusion%3A%20limitations%20and%20promises%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2084%283%29%2C%20pp.%201198%26%23x2013%3B1217.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.28195%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.28195%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Intravoxel%20Incoherent%20Motion%20at%207%20Tesla%20to%20quantify%20human%20spinal%20cord%20perfusion%3A%20limitations%20and%20promises%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Simon%22%2C%22lastName%22%3A%22L%5Cu00e9vy%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Aur%5Cu00e9lien%22%2C%22lastName%22%3A%22Massire%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thomas%22%2C%22lastName%22%3A%22Troalen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thorsten%22%2C%22lastName%22%3A%22Feiweier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Virginie%22%2C%22lastName%22%3A%22Callot%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20develop%20a%20noninvasive%20technique%20to%20map%20human%20spinal%20cord%20%28SC%29%20perfusion%20in%20vivo.%20More%20specifically%2C%20to%20implement%20an%20intravoxel%20incoherent%20motion%20%28IVIM%29%20protocol%20at%20ultrahigh%20field%20for%20the%20human%20SC%20and%20assess%20parameters%20estimation%20errors.%5CnMETHODS%3A%20Monte-Carlo%20simulations%20were%20conducted%20to%20assess%20estimation%20errors%20of%202%20standard%20IVIM%20fitting%20approaches%20%28two-step%20versus%20one-step%20fit%29%20over%20the%20range%20of%20IVIM%20values%20reported%20for%20the%20human%20brain%20and%20for%20typical%20SC%20diffusivities.%20Required%20signal-to-noise%20ratio%20%28SNR%29%20was%20inferred%20for%20estimation%20of%20the%20parameters%20product%2C%20fIVIM%20D%2A%20%28microvascular%20fraction%20times%20pseudo-diffusion%20coefficient%29%2C%20within%2010%25%20error%20margins.%20In-vivo%20IVIM%20imaging%20of%20the%20SC%20was%20performed%20at%207T%20in%206%20volunteers.%20An%20image%5Cu00a0processing%20pipeline%20is%20proposed%20to%20generate%20IVIM%20maps%20and%20register%20them%20for%20an%20atlas-based%20region-wise%20analysis.%5CnRESULTS%3A%20Required%20b%20%3D%200%20SNRs%20for%2010%25%20error%20estimation%20on%20fIVIM%20D%2A%20with%20the%20one-step%20fit%20were%20159%20and%20185%20for%20diffusion-encoding%20perpendicular%20and%20parallel%20to%20the%20SC%20axis%2C%20respectively.%20Average%20in%20vivo%20b%20%3D%200%20SNR%20within%20cord%20was%20141%20%5Cu00b1%2079%2C%20corresponding%20to%20estimation%20errors%20of%2012.7%25%20and%2014.7%25%20according%20to%20numerical%20simulations.%20Slice-%20and%20group-averaging%20reduced%20noise%20in%20IVIM%20maps%2C%20highlighting%20the%20difference%20in%20perfusion%20between%20gray%20and%20white%20matter.%20Mean%20%5Cu00b1%20standard%20deviation%20fIVIM%20and%20D%2A%20values%20across%20subjects%20within%20gray%20%28respectively%20white%29%20matter%20were%2016.0%20%5Cu00b1%201.7%20%2815.0%20%5Cu00b1%201.6%29%25%20and%2011.4%20%5Cu00b1%202.9%20%2811.5%20%5Cu00b1%202.4%29%20%5Cu00d7%2010-3%20mm2%20%5C%2Fs.%5CnCONCLUSION%3A%20Single-subject%20data%20SNR%20at%207T%20was%20insufficient%20for%20reliable%20perfusion%20estimation.%20However%2C%20atlas-averaged%20IVIM%20maps%20highlighted%20the%20higher%20microvascular%20fraction%20of%20gray%20matter%20compared%20to%20white%20matter%2C%20providing%20first%20results%20of%20healthy%20human%20SC%20perfusion%20mapping%20with%20MRI.%22%2C%22date%22%3A%22Sep%202020%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.28195%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22ZFC2Q648%22%2C%226GBQDAVI%22%2C%22SK6VWU7K%22%2C%22HHEPZHEJ%22%2C%22N8KKIHCD%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222024-11-06T10%3A43%3A03Z%22%7D%7D%2C%7B%22key%22%3A%22INFKIYDS%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Habert%20et%20al.%22%2C%22parsedDate%22%3A%222020-05%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BHabert%2C%20P.%2C%20Capron%2C%20T.%2C%20Hubert%2C%20S.%2C%20Bentatou%2C%20Z.%2C%20Bartoli%2C%20A.%2C%20Tradi%2C%20F.%2C%20Renard%2C%20S.%2C%20Rapacchi%2C%20S.%2C%20Guye%2C%20M.%2C%20Bernard%2C%20M.%2C%20Habib%2C%20G.%20and%20Jacquier%2C%20A.%20%282020%29%20%26%23x201C%3BQuantification%20of%20right%20ventricular%20extracellular%20volume%20in%20pulmonary%20hypertension%20using%20cardiac%20magnetic%20resonance%20imaging%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BDiagnostic%20and%20Interventional%20Imaging%26lt%3B%5C%2Fi%26gt%3B%2C%20101%285%29%2C%20pp.%20311%26%23x2013%3B320.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.diii.2019.12.008%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.diii.2019.12.008%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Quantification%20of%20right%20ventricular%20extracellular%20volume%20in%20pulmonary%20hypertension%20using%20cardiac%20magnetic%20resonance%20imaging%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22P.%22%2C%22lastName%22%3A%22Habert%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22T.%22%2C%22lastName%22%3A%22Capron%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22S.%22%2C%22lastName%22%3A%22Hubert%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Z.%22%2C%22lastName%22%3A%22Bentatou%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Bartoli%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22F.%22%2C%22lastName%22%3A%22Tradi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22S.%22%2C%22lastName%22%3A%22Renard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22S.%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22G.%22%2C%22lastName%22%3A%22Habib%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Jacquier%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20The%20purpose%20of%20this%20prospective%20study%20was%20to%20assess%20the%20value%20of%20biventricular%20extracellular%20volume%20%28ECV%29%20in%20pre-capillary%20pulmonary%20hypertension%20%28PH%29%20obtained%20using%20cardiac%20magnetic%20resonance%20imaging%20%28CMR%29%20and%20to%20correlate%20ECV%20with%20markers%20of%20prognosis%20such%20as%20strain%20echocardiography%20and%20blood%20biomarkers%20of%20fibrosis.%5CnMATERIALS%20AND%20METHODS%3A%20Twelve%20patients%20with%20PH%20%286%20men%2C%206%20women%3B%20mean%20age%3D50%5Cu00b116%20%5BSD%5D%20years%3B%20age%20range%3A%2022-73%20years%29%20underwent%20the%20same%20day%3A%20%28i%29%2C%20transthoracic%20echocardiography%20including%20measurement%20of%20right%20ventricular%20%28RV%29%20fractional%20shortening%20%28RVfs%29%2C%20tricuspid%20annular%20plane%20systolic%20excursion%20%28TAPSE%29%2C%20maximal%20tricuspid%20annular%20velocity%2C%20RV%20global%20and%20segmental%20deformation%3B%20%28ii%29%2C%20right%20heart%20catheterization%20measuring%20pulmonary%20arterial%20pressures%20%28inmmHg%29%20and%20cardiac%20output%20%28inL%5C%2Fmin%29%3B%20%28iii%29%2C%20CMR%20at%201.5-T%20measuring%20RV%20volumes%20and%20ejection%20fraction%3B%20%28iv%29%2C%20native%20and%2015min%20post-contrast%20T1%20mapping%20using%20modified%20look-locker%20inversion-recovery%20sequence%3B%20and%20%28v%29%2C%20serum%20quantification%20of%20two%20biomarkers%20of%20collagen%20turnover%20and%20hematocrit.%20Non-parametric%20Mann-Whitney%20tests%20were%20used%20to%20search%20for%20differences%20between%20categorical%20variables.%20Spearman%20correlation%20test%20was%20used%20for%20search%20for%20correlation%20between%20quantitative%20values.%5CnRESULTS%3A%20Global%20RV%20ECV%20was%2034%25%5Cu00b14.2%20%28SD%29%20for%20our%20entire%20population.%20A%20significant%20correlation%20was%20found%20between%20RV%20ECV%20and%20RVfs%20%28r%3D0.6%3B%20P%3D0.026%29%2C%20S%20wave%20velocity%20%28r%3D0.7%3B%20P%3D0.009%29%2C%20TAPSE%20%28r%3D0.6%3B%20P%3D0.040%29%20and%20RV%20systolic%20ejection%20fraction%20on%20CMR%20%28r%3D0.6%3B%20P%3D0.04%29.%20There%20were%20no%20correlations%20between%20the%20ECV%20values%20in%20the%20lateral%20wall%20of%20the%20RV%20and%20in%20the%20septum%20%28r%3D0.4%3B%20P%3D0.206%29.%20A%20significant%20correlation%20was%20found%20between%20septal%20ECV%20and%202D%20septal%20strain%20%28r%3D0.7%3B%20P%3D0.013%29.%5CnCONCLUSION%3A%20ECV%20in%20PH%20as%20obtained%20using%20CMR%20appears%20to%20correlate%20with%20known%20echocardiographic%20prognostic%20markers%20and%20more%20specifically%20with%20the%20markers%2C%20which%20assess%20RV%20systolic%20function.%22%2C%22date%22%3A%22May%202020%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.diii.2019.12.008%22%2C%22ISSN%22%3A%222211-5684%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%225Z6CVJGB%22%2C%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22B4FUISBZ%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222024-06-14T08%3A30%3A12Z%22%7D%7D%2C%7B%22key%22%3A%22C5W3GYUG%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Bentatou%20et%20al.%22%2C%22parsedDate%22%3A%222020-04-15%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BBentatou%2C%20Z.%2C%20Troalen%2C%20T.%2C%20Bernard%2C%20M.%2C%20Guye%2C%20M.%2C%20Pini%2C%20L.%2C%20Bartoli%2C%20A.%2C%20Jacquier%2C%20A.%2C%20Kober%2C%20F.%20and%20Rapacchi%2C%20S.%20%282020%29%20%26%23x201C%3BSimultaneous%20multi-slice%20T1%20mapping%20using%20MOLLI%20with%20blipped%20CAIPIRINHA%20bSSFP%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20Imaging%26lt%3B%5C%2Fi%26gt%3B%2C%20pp.%20S0730-725X%2819%2930796%26%23x2013%3B9.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.mri.2020.03.006%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.mri.2020.03.006%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Simultaneous%20multi-slice%20T1%20mapping%20using%20MOLLI%20with%20blipped%20CAIPIRINHA%20bSSFP%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Zakarya%22%2C%22lastName%22%3A%22Bentatou%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thomas%22%2C%22lastName%22%3A%22Troalen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Monique%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lauriane%22%2C%22lastName%22%3A%22Pini%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Axel%22%2C%22lastName%22%3A%22Bartoli%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alexis%22%2C%22lastName%22%3A%22Jacquier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%22%2C%22lastName%22%3A%22Kober%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%3A%20This%20study%20evaluates%20the%20possibility%20for%20replacing%20conventional%203%20slices%2C%203%20breath-holds%20MOLLI%20cardiac%20T1%20mapping%20with%20single%20breath-hold%203%20simultaneous%20multi-slice%20%28SMS3%29%20T1%20mapping%20using%20blipped-CAIPIRINHA%20SMS-bSSFP%20MOLLI%20sequence.%20As%20a%20major%20drawback%2C%20SMS-bSSFP%20presents%20unique%20artefacts%20arising%20from%20side-lobe%20slice%20excitations%20that%20are%20explained%20by%20imperfect%20RF%20modulation%20rendering%20and%20bSSFP%20low%20flip%20angle%20enhancement.%20Amplitude-only%20RF%20modulation%20%28AM%29%20is%20proposed%20to%20reduce%20these%20artefacts%20in%20SMS-MOLLI%20compared%20to%20conventional%20Wong%20multi-band%20RF%20modulation%20%28WM%29.%5CnMATERIALS%20AND%20METHODS%3A%20Phantoms%20and%20ten%20healthy%20volunteers%20were%20imaged%20at%201.5%5Cu00a0T%20using%20a%20modified%20blipped-CAIPIRINHA%20SMS-bSSFP%20MOLLI%20sequence%20with%203%20simultaneous%20slices.%20WM-SMS3%20and%20AM-SMS3%20were%20compared%20to%20conventional%20single-slice%20%28SMS1%29%20MOLLI.%20First%2C%20SNR%20degradation%20and%20T1%20accuracy%20were%20measured%20in%20phantoms.%20Second%2C%20artefacts%20from%20side-lobe%20excitations%20were%20evaluated%20in%20a%20phantom%20designed%20to%20reproduce%20fat%20presence%20near%20the%20heart.%20Third%2C%20the%20occurrence%20of%20these%20artefacts%20was%20observed%20in%20volunteers%2C%20and%20their%20impact%20on%20T1%20quantification%20was%20compared%20between%20WM-SMS3%20and%20AM-SMS3%20with%20conventional%20MOLLI%20as%20a%20reference.%5CnRESULTS%3A%20In%20the%20phantom%2C%20larger%20slice%20gaps%20and%20slice%20thicknesses%20yielded%20higher%20SNR.%20There%20was%20no%20significant%20difference%20of%20T1%20values%20between%20conventional%20MOLLI%20and%20SMS3-MOLLI%20%28both%20WM%20and%20AM%29.%20Positive%20banding%20artefacts%20were%20identified%20from%20fat%20neighbouring%20the%20targeted%20FOV%20due%20to%20side-lobe%20excitations%20from%20WM%20and%20the%20unique%20bSSFP%20signal%20profile.%20AM%20RF%20pulses%20reduced%20these%20artefacts%20by%2038%25.%20In%20healthy%20volunteers%2C%20AM-SMS3-MOLLI%20showed%20similar%20artefact%20reduction%20compared%20to%20WM-SMS3-MOLLI%20%283%5Cu00a0%5Cu00b1%5Cu00a02%20vs%205%5Cu00a0%5Cu00b1%5Cu00a03%20corrupted%20LV%20segments%20out%20of%2016%29.%20In-vivo%20native%20T1%20values%20obtained%20from%20conventional%20MOLLI%20and%20AM-SMS3-MOLLI%20were%20equivalent%20in%20LV%20myocardium%20%28SMS1-T1%5Cu00a0%3D%5Cu00a0935.5%5Cu00a0%5Cu00b1%5Cu00a036.1%5Cu00a0ms%3B%20AM-SMS3-T1%5Cu00a0%3D%5Cu00a0933.8%5Cu00a0%5Cu00b1%5Cu00a050.2%5Cu00a0ms%3B%20P%5Cu00a0%3D%5Cu00a00.436%29%20and%20LV%20blood%20pool%20%28SMS1-T1%5Cu00a0%3D%5Cu00a01475.4%5Cu00a0%5Cu00b1%5Cu00a035.9%5Cu00a0ms%3B%20AM-SMS3-T1%5Cu00a0%3D%5Cu00a01452.5%5Cu00a0%5Cu00b1%5Cu00a070.3%5Cu00a0ms%3B%20P%5Cu00a0%3D%5Cu00a00.515%29.%20Identically%2C%20no%20differences%20were%20found%20between%20SMS1%20and%20SMS3%20postcontrast%20T1%20values%20in%20the%20myocardium%20%28SMS1-T1%5Cu00a0%3D%5Cu00a0556.0%5Cu00a0%5Cu00b1%5Cu00a019.7%5Cu00a0ms%3B%20SMS3-T1%5Cu00a0%3D%5Cu00a0521.3%5Cu00a0%5Cu00b1%5Cu00a028.1%5Cu00a0ms%3B%20P%5Cu00a0%3D%5Cu00a00.626%29%20and%20the%20blood%20%28SMS1-T1%5Cu00a0%3D%5Cu00a0478%5Cu00a0%5Cu00b1%5Cu00a065.1%5Cu00a0ms%3B%20AM-SMS3-T1%5Cu00a0%3D%5Cu00a0447.8%5Cu00a0%5Cu00b1%5Cu00a081.5%3B%20P%5Cu00a0%3D%5Cu00a00.085%29.%5CnCONCLUSIONS%3A%20Compared%20to%20WM%20RF%20modulation%2C%20AM%20SMS-bSSFP%20MOLLI%20was%20able%20to%20reduce%20side-lobe%20artefacts%20considerably%2C%20providing%20promising%20results%20to%20image%20the%20three%20levels%20of%20the%20heart%20in%20a%20single%20breath%20hold.%20However%2C%20few%20artefacts%20remained%20even%20using%20AM-SMS-bSSFP%20due%20to%20residual%20RF%20imperfections.%20The%20proposed%20blipped-CAIPIRINHA%20MOLLI%20T1%20mapping%20sequence%20provides%20accurate%20in%20vivo%20T1%20quantification%20in%20line%20with%20those%20obtained%20with%20a%20single%20slice%20acquisition.%22%2C%22date%22%3A%222020-04-15%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.mri.2020.03.006%22%2C%22ISSN%22%3A%221873-5894%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%226GBQDAVI%22%2C%225Z6CVJGB%22%2C%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22B4FUISBZ%22%2C%22XTA6KS7L%22%2C%22BR9D2SS4%22%2C%22CXAMISN8%22%5D%2C%22dateModified%22%3A%222024-06-14T08%3A30%3A17Z%22%7D%7D%2C%7B%22key%22%3A%22DBCCP5WZ%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Rapacchi%20et%20al.%22%2C%22parsedDate%22%3A%222019-04%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BRapacchi%2C%20S.%2C%20Troalen%2C%20T.%2C%20Bentatou%2C%20Z.%2C%20Quemeneur%2C%20M.%2C%20Guye%2C%20M.%2C%20Bernard%2C%20M.%2C%20Jacquier%2C%20A.%20and%20Kober%2C%20F.%20%282019%29%20%26%23x201C%3BSimultaneous%20multi-slice%20cardiac%20cine%20with%20Fourier-encoded%20self-calibration%20at%207%20Tesla%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2081%284%29%2C%20pp.%202576%26%23x2013%3B2587.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.27593%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.27593%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Simultaneous%20multi-slice%20cardiac%20cine%20with%20Fourier-encoded%20self-calibration%20at%207%20Tesla%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thomas%22%2C%22lastName%22%3A%22Troalen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Zakarya%22%2C%22lastName%22%3A%22Bentatou%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Morgane%22%2C%22lastName%22%3A%22Quemeneur%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Monique%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alexis%22%2C%22lastName%22%3A%22Jacquier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%22%2C%22lastName%22%3A%22Kober%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20accelerate%20cardiac%20cine%20at%207%20tesla%20using%20simultaneous%20multi-slice%20%28SMS%29%20acquisition%20with%20self-calibration%20to%20resolve%20misalignment%20between%20calibration%20and%20imaging%20data%20due%20to%20breathing%20motion.%5CnMETHODS%3A%20A%20spoiled-gradient%20echo%20cine%20sequence%20was%20modified%20with%20radiofrequency%20phase-cycled%20SMS%20excitations.%20A%20Fourier%20encoding%20strategy%20was%20applied%20along%20the%20cardiac%20phase%20dimension%20to%20allow%20for%20slice%20untangling%20and%20split-slice%20GRAPPA%20calibration.%20Split-slice%20GRAPPA%20was%20coupled%20with%20regular%20GRAPPA%20%28SMS-GRAPPA%29%20and%20L1-SPIRiT%20%28SMS-L1SPIRiT%29%20for%20image%20reconstruction.%203-slice%20SMS%20cine%20MRI%20was%20evaluated%20in%20ten%20subjects%20against%20single-slice%20cine%20MRI%20in%20terms%20of%20SNR%20and%20contrast-to-noise%20ratio%20and%20slice%20leakage.%5CnRESULTS%3A%20SNR%20decreased%20significantly%20from%2010.1%20%5Cu00b1%207.1%20for%20single-slice%20cine%20to%207.4%20%5Cu00b1%202.8%20for%20SMS-GRAPPA%20%28P%20%3D%200.02%29%20and%20was%20recovered%20to%209.0%20%5Cu00b1%204.5%20with%20SMS-L1SPIRiT%20%28P%20%3D%200.02%29.%20Contrast%20to%20noise%20ratio%20decreased%20significantly%20from%2014.5%20%5Cu00b1%208.1%20for%20single-slice%20cine%20to%205.6%20%5Cu00b1%203.6%20for%20SMS-GRAPPA%20%28P%20%26lt%3B%200.0001%29%20and%20increased%20slightly%20but%20significantly%20back%20to%206.7%20%5Cu00b1%204.4%20for%20SMS-L1SPIRiT%20%28P%20%3D%200.03%29.%20Specific%20absorption%20rate%20restrictions%20imposed%20a%20reduced%20nominal%20flip%20angle%20%28-37%20%5Cu00b1%207%25%2C%20P%20%3D%200.02%29%20for%203-slice%20SMS%20excitations%20compared%20to%20single-slice%20acquisitions.%20SMS%20slice%20leakage%20increased%20significantly%20from%20apex%20%288.6%20%5Cu00b1%206.5%20%25%29%20to%20base%20%2813.1%20%5Cu00b1%204.1%20%25%2C%20P%20%3D%200.03%29%20in%20the%20left%20ventricle.%5CnCONCLUSION%3A%20Three-fold%20acceleration%20of%20cine%20at%207T%20was%20achieved%20using%20the%20proposed%20SMS%20technique.%20Fourier%20encoding%20self-calibration%20and%20regularized%20image%20reconstruction%20enabled%20simultaneous%20acquisition%20of%20three%20slices%20without%20significant%20SNR%20decrease%20but%20significant%20CNR%20decrease%20linked%20to%20the%20reduced%20nominal%20excitation%20flip%20angle.%22%2C%22date%22%3A%22Apr%202019%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.27593%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%226GBQDAVI%22%2C%225Z6CVJGB%22%2C%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22B4FUISBZ%22%2C%22XTA6KS7L%22%2C%22BR9D2SS4%22%5D%2C%22dateModified%22%3A%222024-06-14T08%3A30%3A17Z%22%7D%7D%2C%7B%22key%22%3A%22GB4K2JLV%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Wei%20et%20al.%22%2C%22parsedDate%22%3A%222019-02-26%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BWei%2C%20W.%2C%20Evin%2C%20M.%2C%20Rapacchi%2C%20S.%2C%20Kober%2C%20F.%2C%20Bernard%2C%20M.%2C%20Jacquier%2C%20A.%2C%20Kahn%2C%20C.J.F.%20and%20Behr%2C%20M.%20%282019%29%20%26%23x201C%3BInvestigating%20heartbeat-related%20in-plane%20motion%20and%20stress%20levels%20induced%20at%20the%20aortic%20root%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BBiomedical%20Engineering%20Online%26lt%3B%5C%2Fi%26gt%3B%2C%2018%281%29%2C%20p.%2019.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1186%5C%2Fs12938-019-0632-7%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1186%5C%2Fs12938-019-0632-7%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Investigating%20heartbeat-related%20in-plane%20motion%20and%20stress%20levels%20induced%20at%20the%20aortic%20root%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Wei%22%2C%22lastName%22%3A%22Wei%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Morgane%22%2C%22lastName%22%3A%22Evin%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%22%2C%22lastName%22%3A%22Kober%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Monique%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alexis%22%2C%22lastName%22%3A%22Jacquier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Cyril%20J.%20F.%22%2C%22lastName%22%3A%22Kahn%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Michel%22%2C%22lastName%22%3A%22Behr%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%3A%20The%20axial%20motion%20of%20aortic%20root%20%28AR%29%20due%20to%20ventricular%20traction%20was%20previously%20suggested%20to%20contribute%20to%20ascending%20aorta%20%28AA%29%20dissection%20by%20increasing%20its%20longitudinal%20stress%2C%20but%20AR%20in-plane%20motion%20effects%20on%20stresses%20have%20never%20been%20studied.%20The%20objective%20is%20to%20investigate%20the%20contribution%20of%20AR%20in-plane%20motion%20to%20AA%20stress%20levels.%5CnMETHODS%3A%20The%20AR%20in-plane%20motion%20was%20assessed%20on%20magnetic%20resonance%20imagining%20data%20from%2025%20healthy%20volunteers%20as%20the%20movement%20of%20the%20AA%20section%20centroid.%20The%20measured%20movement%20was%20prescribed%20to%20the%20proximal%20AA%20end%20of%20an%20aortic%20finite%20element%20model%20to%20investigate%20its%20influences%20on%20aortic%20stresses.%20The%20finite%20element%20model%20was%20developed%20from%20a%20patient-specific%20geometry%20using%20LS-DYNA%20solver%20and%20validated%20against%20the%20aortic%20distensibility.%20Fluid-structure%20interaction%20%28FSI%29%20approach%20was%20also%20used%20to%20simulate%20blood%20hydrodynamic%20effects%20on%20aortic%20dilation%20and%20stresses.%5CnRESULTS%3A%20The%20AR%20in-plane%20motion%20was%205.5%5Cu2009%5Cu00b1%5Cu20091.7%5Cu00a0mm%20with%20the%20components%20of%203.1%5Cu2009%5Cu00b1%5Cu20091.5%5Cu00a0mm%20along%20the%20direction%20of%20proximal%20descending%20aorta%20%28PDA%29%20to%20AA%20centroid%20and%203.0%5Cu2009%5Cu00b1%5Cu20091.3%5Cu00a0mm%20perpendicularly%20under%20the%20PDA%20reference%20system.%20The%20AR%20axial%20motion%20elevated%20the%20longitudinal%20stress%20of%20proximal%20AA%20by%2040%25%20while%20the%20corresponding%20increase%20due%20to%20in-plane%20motion%20was%20always%20below%205%25.%20The%20stresses%20at%20proximal%20AA%20resulted%20approximately%207%25%20less%20in%20FSI%20simulation%20with%20blood%20flow.%5CnCONCLUSIONS%3A%20The%20AR%20in-plane%20motion%20was%20comparable%20with%20the%20magnitude%20of%20axial%20motion.%20Neither%20axial%20nor%20in-plane%20motion%20could%20directly%20lead%20to%20AA%20dissection.%20It%20is%20necessary%20to%20consider%20the%20heterogeneous%20pressures%20related%20to%20blood%20hydrodynamics%20when%20studying%20aortic%20wall%20stress%20levels.%22%2C%22date%22%3A%22Feb%2026%2C%202019%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1186%5C%2Fs12938-019-0632-7%22%2C%22ISSN%22%3A%221475-925X%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%225Z6CVJGB%22%2C%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22BR9D2SS4%22%5D%2C%22dateModified%22%3A%222024-06-14T08%3A31%3A08Z%22%7D%7D%2C%7B%22key%22%3A%22RXT5YMEJ%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Trotier%20et%20al.%22%2C%22parsedDate%22%3A%222019-01%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BTrotier%2C%20A.J.%2C%20Rapacchi%2C%20S.%2C%20Faller%2C%20T.L.%2C%20Miraux%2C%20S.%20and%20Ribot%2C%20E.J.%20%282019%29%20%26%23x201C%3BCompressed-Sensing%20MP2RAGE%20sequence%3A%20Application%20to%20the%20detection%20of%20brain%20metastases%20in%20mice%20at%207T%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2081%281%29%2C%20pp.%20551%26%23x2013%3B559.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.27438%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.27438%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Compressed-Sensing%20MP2RAGE%20sequence%3A%20Application%20to%20the%20detection%20of%20brain%20metastases%20in%20mice%20at%207T%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Aur%5Cu00e9lien%20J.%22%2C%22lastName%22%3A%22Trotier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Thibaut%20L.%22%2C%22lastName%22%3A%22Faller%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Sylvain%22%2C%22lastName%22%3A%22Miraux%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Emeline%20J.%22%2C%22lastName%22%3A%22Ribot%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20develop%20a%20Compressed%20Sensing%20%28CS%29-MP2RAGE%20sequence%20to%20drastically%20shorten%20acquisition%20duration%20and%20then%20detect%20and%20measure%20the%20T1%20of%20brain%20metastases%20in%20mice%20at%207%5Cu00a0T.%5CnMETHODS%3A%20The%20encoding%20trajectory%20of%20the%20standard%20Cartesian%20MP2RAGE%20sequence%20has%20been%20modified%20%281%29%20to%20obtain%20a%20variable%20density%20Poisson%20disk%20under-sampling%20distribution%20along%20the%20ky%20-kz%20plane%2C%20and%20%282%29%20to%20sample%20the%20central%20part%20of%20the%20k-space%20exactly%20at%20TI1%20and%20TI2%20inversion%20times.%20In%20a%20prospective%20study%2C%20the%20accuracy%20of%20the%20T1%20measurements%20was%20evaluated%20on%20phantoms%20containing%20increasing%20concentrations%20of%20gadolinium.%20The%20CS%20acceleration%20factors%20were%20increased%20to%20evaluate%20their%20influence%20on%20the%20contrast%20and%20T1%20measurements%20of%20brain%20metastases%20in%20vivo.%20Finally%2C%20the%203D%20T1%20maps%20were%20acquired%20with%20at%204-fold%20increased%20spatial%20resolution.%20The%20volumes%20and%20T1%20values%20of%20the%20metastases%20were%20measured%20while%20using%20CS%20to%20reduce%20scan%20time.%5CnRESULTS%3A%20The%20implementation%20of%20the%20CS-encoding%20trajectory%20did%20not%20affect%20the%20T1%20measurements%20in%20vitro.%20Accelerating%20the%20acquisition%20by%20a%20factor%20of%202%20did%20not%20alter%20the%20contrast%20or%20the%20T1%20values%20of%20the%20brain%20metastases.%203D%20T1%20maps%20could%20be%20obtained%20in%5Cu00a0%26lt%3B%5Cu00a01%5Cu00a0min%20using%20a%20CS%20factor%20of%206.%20Increasing%20the%20spatial%20resolution%20enabled%20more%20accurately%20measurement%20of%20the%20metastasis%20volumes%20while%20maintaining%20an%20acquisition%20duration%20below%205%5Cu00a0min.%5CnCONCLUSION%3A%20The%20CS-MP2RAGE%20sequence%20could%20be%20of%20great%20interest%20in%20oncology%20to%20either%20rapidly%20obtain%20mouse%20brain%203D%20T1%20maps%20or%20to%20increase%20the%20spatial%20resolution%20with%20no%20penalty%20on%20the%20scan%20duration.%22%2C%22date%22%3A%22Jan%202019%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.27438%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222025-11-27T09%3A19%3A39Z%22%7D%7D%2C%7B%22key%22%3A%22HIPZ7WSJ%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Donadieu%20et%20al.%22%2C%22parsedDate%22%3A%222019%22%2C%22numChildren%22%3A3%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BDonadieu%2C%20M.%2C%20Le%20Fur%2C%20Y.%2C%20Maarouf%2C%20A.%2C%20Gherib%2C%20S.%2C%20Ridley%2C%20B.%2C%20Pini%2C%20L.%2C%20Rapacchi%2C%20S.%2C%20Confort-Gouny%2C%20S.%2C%20Guye%2C%20M.%2C%20Schad%2C%20L.R.%2C%20Maudsley%2C%20A.A.%2C%20Pelletier%2C%20J.%2C%20Audoin%2C%20B.%2C%20Zaaraoui%2C%20W.%20and%20Ranjeva%2C%20J.-P.%20%282019%29%20%26%23x201C%3BMetabolic%20counterparts%20of%20sodium%20accumulation%20in%20multiple%20sclerosis%3A%20A%20whole%20brain%2023Na-MRI%20and%20fast%201H-MRSI%20study%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMultiple%20Sclerosis%20%28Houndmills%2C%20Basingstoke%2C%20England%29%26lt%3B%5C%2Fi%26gt%3B%2C%2025%281%29%2C%20pp.%2039%26%23x2013%3B47.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1177%5C%2F1352458517736146%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1177%5C%2F1352458517736146%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Metabolic%20counterparts%20of%20sodium%20accumulation%20in%20multiple%20sclerosis%3A%20A%20whole%20brain%2023Na-MRI%20and%20fast%201H-MRSI%20study%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Donadieu%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Yann%22%2C%22lastName%22%3A%22Le%20Fur%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Adil%22%2C%22lastName%22%3A%22Maarouf%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Soraya%22%2C%22lastName%22%3A%22Gherib%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ben%22%2C%22lastName%22%3A%22Ridley%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lauriane%22%2C%22lastName%22%3A%22Pini%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Sylviane%22%2C%22lastName%22%3A%22Confort-Gouny%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lothar%20R.%22%2C%22lastName%22%3A%22Schad%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Andrew%20A.%22%2C%22lastName%22%3A%22Maudsley%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jean%22%2C%22lastName%22%3A%22Pelletier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Bertrand%22%2C%22lastName%22%3A%22Audoin%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Wafaa%22%2C%22lastName%22%3A%22Zaaraoui%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jean-Philippe%22%2C%22lastName%22%3A%22Ranjeva%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%3A%20Increase%20of%20brain%20total%20sodium%20concentrations%20%28TSC%29%20is%20present%20in%20multiple%20sclerosis%20%28MS%29%2C%20but%20its%20pathological%20involvement%20has%20not%20been%20assessed%20yet.%5CnOBJECTIVE%3A%20To%20determine%20in%20vivo%20the%20metabolic%20counterpart%20of%20brain%20sodium%20accumulation.%5CnMATERIALS%5C%2FMETHODS%3A%20Whole%20brain%2023Na-MR%20imaging%20and%203D-1H-EPSI%20data%20were%20collected%20in%2021%20relapsing-remitting%20multiple%20sclerosis%20%28RRMS%29%20patients%20and%2020%20volunteers.%20Metabolites%20and%20sodium%20levels%20were%20extracted%20from%20several%20regions%20of%20grey%20matter%20%28GM%29%2C%20normal-appearing%20white%20matter%20%28NAWM%29%20and%20white%20matter%20%28WM%29%20T2%20lesions.%20Metabolic%20and%20ionic%20levels%20expressed%20as%20Z-scores%20have%20been%20averaged%20over%20the%20different%20compartments%20and%20used%20to%20explain%20sodium%20accumulations%20through%20stepwise%20regression%20models.%5CnRESULTS%3A%20MS%20patients%20showed%20significant%2023Na%20accumulations%20with%20lower%20choline%20and%20glutamate-glutamine%20%28Glx%29%20levels%20in%20GM%3B%2023Na%20accumulations%20with%20lower%20N-acetyl%20aspartate%20%28NAA%29%2C%20Glx%20levels%20and%20higher%20Myo-Inositol%20%28m-Ins%29%20in%20NAWM%3B%20and%20higher%2023Na%2C%20m-Ins%20levels%20with%20lower%20NAA%20in%20WM%20T2%20lesions.%20Regression%20models%20showed%20associations%20of%20TSC%20increase%20with%20reduced%20NAA%20in%20GM%2C%20NAWM%20and%20T2%20lesions%2C%20as%20well%20as%20higher%20total-creatine%2C%20and%20smaller%20decrease%20of%20m-Ins%20in%20T2%20lesions.%20GM%20Glx%20levels%20were%20associated%20with%20clinical%20scores.%5CnCONCLUSION%3A%20Increase%20of%20TSC%20in%20RRMS%20is%20mainly%20related%20to%20neuronal%20mitochondrial%20dysfunction%20while%20dysfunction%20of%20neuro-glial%20interactions%20within%20GM%20is%20linked%20to%20clinical%20scores.%22%2C%22date%22%3A%2201%202019%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1177%5C%2F1352458517736146%22%2C%22ISSN%22%3A%221477-0970%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SVI8UJ6H%22%2C%227JR7EDKF%22%2C%22KJQH9V8M%22%2C%22UP3H3ICX%22%2C%22HVJZKIZG%22%2C%22B4EWFM7E%22%2C%22P66W67T8%22%2C%22SK6VWU7K%22%2C%226NQZK62Z%22%2C%226KPLZTET%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222024-11-26T16%3A01%3A10Z%22%7D%7D%2C%7B%22key%22%3A%22CQEBKAZM%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Bentatou%20et%20al.%22%2C%22parsedDate%22%3A%222018-11%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BBentatou%2C%20Z.%2C%20Finas%2C%20M.%2C%20Habert%2C%20P.%2C%20Kober%2C%20F.%2C%20Guye%2C%20M.%2C%20Bricq%2C%20S.%2C%20Lalande%2C%20A.%2C%20Frandon%2C%20J.%2C%20Dacher%2C%20J.N.%2C%20Dubourg%2C%20B.%2C%20Habib%2C%20G.%2C%20Caudron%2C%20J.%2C%20Normant%2C%20S.%2C%20Rapacchi%2C%20S.%2C%20Bernard%2C%20M.%20and%20Jacquier%2C%20A.%20%282018%29%20%26%23x201C%3BDistribution%20of%20left%20ventricular%20trabeculation%20across%20age%20and%20gender%20in%20140%20healthy%20Caucasian%20subjects%20on%20MR%20imaging%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BDiagnostic%20and%20Interventional%20Imaging%26lt%3B%5C%2Fi%26gt%3B%2C%2099%2811%29%2C%20pp.%20689%26%23x2013%3B698.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.diii.2018.08.014%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.diii.2018.08.014%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Distribution%20of%20left%20ventricular%20trabeculation%20across%20age%20and%20gender%20in%20140%20healthy%20Caucasian%20subjects%20on%20MR%20imaging%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Z.%22%2C%22lastName%22%3A%22Bentatou%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Finas%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22P.%22%2C%22lastName%22%3A%22Habert%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22F.%22%2C%22lastName%22%3A%22Kober%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22S.%22%2C%22lastName%22%3A%22Bricq%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Lalande%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22J.%22%2C%22lastName%22%3A%22Frandon%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22J.%20N.%22%2C%22lastName%22%3A%22Dacher%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22B.%22%2C%22lastName%22%3A%22Dubourg%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22G.%22%2C%22lastName%22%3A%22Habib%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22J.%22%2C%22lastName%22%3A%22Caudron%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22S.%22%2C%22lastName%22%3A%22Normant%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22S.%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22M.%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22A.%22%2C%22lastName%22%3A%22Jacquier%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20The%20purpose%20of%20this%20study%20was%20to%20quantify%20the%20distribution%20of%20trabeculated%20%28T%29%20and%20compact%20%28C%29%20left%20ventricular%20%28LV%29%20myocardium%20masses%20in%20a%20healthy%20Caucasian%20population%20against%20age%2C%20gender%20and%20LV%20parameters%2C%20and%20to%20provide%20normal%20values%20for%20T%2C%20C%20and%20T%5C%2FC.%5CnMATERIALS%20AND%20METHODS%3A%20One%20hundred%20and%20forty%20healthy%20subjects%20were%20prospectively%20recruited%20and%20underwent%20cardiac%20MRI%20at%201.5T%20with%20a%20stack%20of%20short-axis%20cine%20sequences%20covering%20the%20entire%20LV.%20End-diastolic%20volume%20%28EDV%29%2C%20C%20and%20T%20masses%20were%20quantified%20using%20a%20semi-automatic%20method.%20Ejection%20fraction%20%28EF%29%20and%20T%5C%2FC%20ratio%20were%20computed.%5CnRESULTS%3A%20We%20included%2070%20men%20and%2070%20women%20with%20a%20mean%20age%20of%2044%5Cu00b114%20%28SD%29%20years%20%28range%3A%2020-69%20years%29.%20The%20mean%20EF%20was%2063.7%5Cu00b16.3%20%28SD%29%20%25%20%28range%3A%2050.7-82.0%25%29%2C%20the%20mean%20EDV%20was%2075.9%5Cu00b116.2%20%28SD%29%20mL%5C%2Fm2%20%28range%3A%2036.4-112.2mL%5C%2Fm2%29%2C%20the%20mean%20C%20mass%20was%2053.9%5Cu00b111.2%20%28SD%29%20g%5C%2Fm2%20%28range%3A%2026.5-93.4g%5C%2Fm2%29%20and%20the%20mean%20T%20mass%20was%204.9%5Cu00b12.4%20%28SD%29%20g%5C%2Fm2%20%28range%3A%201.1-11.4g%5C%2Fm2%29.%20The%20T%5C%2FC%20ratio%20was%209.2%5Cu00b14.5%25%20%28range%3A%202.0-29.4%25%29.%20Multivariate%20ANOVA%20test%20showed%20that%20the%20compact%20mass%20was%20influenced%20by%20EDV%20%28P%26lt%3B0.0001%29%2C%20EF%20%28P%3D0.001%29%20and%20gender%20%28P%26lt%3B0.0001%29%2C%20and%20the%20trabeculated%20mass%20depended%20on%20EDV%20%28P%26lt%3B0.0001%29%2C%20gender%20%28P%3D0.002%29%20and%20age%20%28P%26lt%3B0.0001%29%2C%20while%20the%20T%5C%2FC%20ratio%20was%20only%20influenced%20by%20age%20%28P%3D0.0003%29.%20Spearman%20test%20showed%20a%20correlation%20between%20EDV%20and%20C%20%28r%3D0.60%3B%20P%26lt%3B0.0001%29%2CT%20%28r%3D0.46%3B%20P%26lt%3B0.0001%29%20and%20T%5C%2FC%20ratio%20%28r%3D0.26%3B%20P%3D0.0023%29.T%20and%20T%5C%2FC%20ratio%20correlated%20with%20EF%20%28r%3D-0.18%2C%20P%3D0.0373%3B%20r%3D-0.18%2C%20P%3D0.0321%2C%20respectively%29.%5CnCONCLUSION%3A%20While%20the%20compact%20and%20trabeculated%20myocardium%20masses%20appear%20to%20relate%20separately%20to%20the%20cardiac%20function%2C%20age%20and%20gender%2C%20their%20ratio%20T%5C%2FC%20appears%20to%20only%20decrease%20with%20age.%20Furthermore%2C%20we%20propose%20here%20normal%20values%20for%20T%2C%20C%20and%20T%5C%2FC%20in%20a%20cohort%20of%20healthy%20Caucasians%20subjects.%22%2C%22date%22%3A%22Nov%202018%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.diii.2018.08.014%22%2C%22ISSN%22%3A%222211-5684%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%225Z6CVJGB%22%2C%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22B4FUISBZ%22%2C%22XTA6KS7L%22%2C%22BR9D2SS4%22%5D%2C%22dateModified%22%3A%222024-06-14T08%3A30%3A14Z%22%7D%7D%2C%7B%22key%22%3A%22RQEPEMKH%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Mchinda%20et%20al.%22%2C%22parsedDate%22%3A%222018-05%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BMchinda%2C%20S.%2C%20Varma%2C%20G.%2C%20Prevost%2C%20V.H.%2C%20Le%20Troter%2C%20A.%2C%20Rapacchi%2C%20S.%2C%20Guye%2C%20M.%2C%20Pelletier%2C%20J.%2C%20Ranjeva%2C%20J.-P.%2C%20Alsop%2C%20D.C.%2C%20Duhamel%2C%20G.%20and%20Girard%2C%20O.M.%20%282018%29%20%26%23x201C%3BWhole%20brain%20inhomogeneous%20magnetization%20transfer%20%28ihMT%29%20imaging%3A%20Sensitivity%20enhancement%20within%20a%20steady-state%20gradient%20echo%20sequence%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2079%285%29%2C%20pp.%202607%26%23x2013%3B2619.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.26907%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.26907%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Whole%20brain%20inhomogeneous%20magnetization%20transfer%20%28ihMT%29%20imaging%3A%20Sensitivity%20enhancement%20within%20a%20steady-state%20gradient%20echo%20sequence%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Samira%22%2C%22lastName%22%3A%22Mchinda%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Gopal%22%2C%22lastName%22%3A%22Varma%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Valentin%20H.%22%2C%22lastName%22%3A%22Prevost%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Arnaud%22%2C%22lastName%22%3A%22Le%20Troter%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jean%22%2C%22lastName%22%3A%22Pelletier%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jean-Philippe%22%2C%22lastName%22%3A%22Ranjeva%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22David%20C.%22%2C%22lastName%22%3A%22Alsop%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Guillaume%22%2C%22lastName%22%3A%22Duhamel%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Olivier%20M.%22%2C%22lastName%22%3A%22Girard%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20implement%2C%20characterize%2C%20and%20optimize%20an%20interleaved%20inhomogeneous%20magnetization%20transfer%20%28ihMT%29%20gradient%20echo%20sequence%20allowing%20for%20whole-brain%20imaging%20within%20a%20clinically%20compatible%20scan%20time.%5CnTHEORY%20AND%20METHODS%3A%20A%20general%20framework%20for%20ihMT%20modelling%20was%20developed%20based%20on%20the%20Provotorov%20theory%20of%20radiofrequency%20saturation%2C%20which%20accounts%20for%20the%20dipolar%20order%20underpinning%20the%20ihMT%20effect.%20Experimental%20studies%20and%20numerical%20simulations%20were%20performed%20to%20characterize%20and%20optimize%20the%20ihMT-gradient%20echo%20dependency%20with%20sequence%20timings%2C%20saturation%20power%2C%20and%20offset%20frequency.%20The%20protocol%20was%20optimized%20in%20terms%20of%20maximum%20signal%20intensity%20and%20the%20reproducibility%20assessed%20for%20a%20nominal%20resolution%20of%201.5%5Cu2009mm%20isotropic.%20All%20experiments%20were%20performed%20on%20healthy%20volunteers%20at%201.5T.%5CnRESULTS%3A%20An%20important%20mechanism%20driving%20signal%20optimization%20and%20leading%20to%20strong%20ihMT%20signal%20enhancement%20that%20relies%20on%20the%20dynamics%20of%20radiofrequency%20energy%20deposition%20has%20been%20identified.%20By%20taking%20advantage%20of%20the%20delay%20allowed%20for%20readout%20between%20ihMT%20pulse%20bursts%2C%20it%20was%20possible%20to%20boost%20the%20ihMT%20signal%20by%20almost%202-fold%20compared%20to%20previous%20implementation.%20Reproducibility%20of%20the%20optimal%20protocol%20was%20very%20good%2C%20with%20an%20intra-individual%20error%5Cu2009%26lt%3B%5Cu20092%25.%5CnCONCLUSION%3A%20The%20proposed%20sensitivity-boosted%20and%20time-efficient%20steady-state%20ihMT-gradient%20echo%20sequence%2C%20implemented%20and%20optimized%20at%201.5T%2C%20allowed%20robust%20high-resolution%203D%20ihMT%20imaging%20of%20the%20whole%20brain%20within%20a%20clinically%20compatible%20scan%20time.%20Magn%20Reson%20Med%2079%3A2607-2619%2C%202018.%20%5Cu00a9%202017%20International%20Society%20for%20Magnetic%20Resonance%20in%20Medicine.%22%2C%22date%22%3A%22May%202018%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.26907%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%2274RX9758%22%2C%224U7D3E9U%22%2C%22XEAP6RQ7%22%2C%22UP3H3ICX%22%2C%22B4EWFM7E%22%2C%22SK6VWU7K%22%2C%225P5FWCR9%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222025-11-27T09%3A21%3A06Z%22%7D%7D%2C%7B%22key%22%3A%22UNHHVXJI%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Zhou%20et%20al.%22%2C%22parsedDate%22%3A%222018-02%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BZhou%2C%20Z.%2C%20Han%2C%20F.%2C%20Yu%2C%20S.%2C%20Yu%2C%20D.%2C%20Rapacchi%2C%20S.%2C%20Song%2C%20H.K.%2C%20Wang%2C%20D.J.J.%2C%20Hu%2C%20P.%20and%20Yan%2C%20L.%20%282018%29%20%26%23x201C%3BAccelerated%20noncontrast-enhanced%204-dimensional%20intracranial%20MR%20angiography%20using%20golden-angle%20stack-of-stars%20trajectory%20and%20compressed%20sensing%20with%20magnitude%20subtraction%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2079%282%29%2C%20pp.%20867%26%23x2013%3B878.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.26747%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.26747%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Accelerated%20noncontrast-enhanced%204-dimensional%20intracranial%20MR%20angiography%20using%20golden-angle%20stack-of-stars%20trajectory%20and%20compressed%20sensing%20with%20magnitude%20subtraction%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ziwu%22%2C%22lastName%22%3A%22Zhou%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fei%22%2C%22lastName%22%3A%22Han%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Songlin%22%2C%22lastName%22%3A%22Yu%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Dandan%22%2C%22lastName%22%3A%22Yu%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Hee%20Kwon%22%2C%22lastName%22%3A%22Song%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Danny%20J.%20J.%22%2C%22lastName%22%3A%22Wang%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Peng%22%2C%22lastName%22%3A%22Hu%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lirong%22%2C%22lastName%22%3A%22Yan%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20evaluate%20the%20feasibility%20and%20performance%20of%20compressed%20sensing%20%28CS%29%20with%20magnitude%20subtraction%20regularization%20in%20accelerating%20non-contrast-enhanced%20dynamic%20intracranial%20MR%20angiography%20%28NCE-dMRA%29.%5CnMETHODS%3A%20A%20CS%20algorithm%20was%20introduced%20in%20NCE-dMRA%20by%20exploiting%20the%20sparsity%20of%20the%20magnitude%20difference%20of%20the%20control%20and%20label%20images.%20The%20NCE-dMRA%20data%20were%20acquired%20using%20golden-angle%20stack-of-stars%20trajectory%20on%20six%20healthy%20volunteers%20and%20one%20patient%20with%20arteriovenous%20fistula.%20Images%20were%20reconstructed%20using%20%28i%29%20the%20proposed%20magnitude-subtraction%20CS%20%28MS-CS%29%3B%20%28ii%29%20complex-subtraction%20CS%3B%20%28iii%29%20independent%20CS%3B%20and%20%28iv%29%20view-sharing%20with%20k-space%20weighted%20image%20contrast%20%28KWIC%29.%20The%20dMRA%20image%20quality%20was%20compared%20across%20the%20four%20reconstruction%20strategies.%20The%20proposed%20MS-CS%20method%20was%20further%20compared%20with%20KWIC%20for%20temporal%20fidelity%20of%20depicting%20dynamic%20flow.%5CnRESULTS%3A%20The%20proposed%20MS-CS%20method%20was%20able%20to%20reconstruct%20NCE-dMRA%20images%20with%20detailed%20vascular%20structures%20and%20clean%20background.%20It%20provided%20better%20subjective%20image%20quality%20than%20the%20other%20two%20CS%20strategies%20%28P%5Cu2009%26lt%3B%5Cu20090.05%29.%20Compared%20with%20KWIC%2C%20MS-CS%20showed%20similar%20image%20quality%2C%20but%20reduced%20temporal%20blurring%20in%20delineating%20the%20fine%20distal%20arteries.%5CnCONCLUSIONS%3A%20The%20MS-CS%20method%20is%20a%20promising%20CS%20technique%20for%20accelerating%20NCE-dMRA%20acquisition%20without%20compromising%20image%20quality%20and%20temporal%20fidelity.%20Magn%20Reson%20Med%2079%3A867-878%2C%202018.%20%5Cu00a9%202017%20International%20Society%20for%20Magnetic%20Resonance%20in%20Medicine.%22%2C%22date%22%3A%22Feb%202018%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.26747%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222023-11-23T14%3A09%3A17Z%22%7D%7D%2C%7B%22key%22%3A%22HIJ99ILP%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Habert%20et%20al.%22%2C%22parsedDate%22%3A%222018%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BHabert%2C%20P.%2C%20Bentatou%2C%20Z.%2C%20Aldebert%2C%20P.%2C%20Finas%2C%20M.%2C%20Bartoli%2C%20A.%2C%20Bal%2C%20L.%2C%20Lalande%2C%20A.%2C%20Rapacchi%2C%20S.%2C%20Guye%2C%20M.%2C%20Kober%2C%20F.%2C%20Bernard%2C%20M.%20and%20Jacquier%2C%20A.%20%282018%29%20%26%23x201C%3BExercise%20stress%20CMR%20reveals%20reduced%20aortic%20distensibility%20and%20impaired%20right-ventricular%20adaptation%20to%20exercise%20in%20patients%20with%20repaired%20tetralogy%20of%20Fallot%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BPloS%20One%26lt%3B%5C%2Fi%26gt%3B%2C%2013%2812%29%2C%20p.%20e0208749.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1371%5C%2Fjournal.pone.0208749%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1371%5C%2Fjournal.pone.0208749%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Exercise%20stress%20CMR%20reveals%20reduced%20aortic%20distensibility%20and%20impaired%20right-ventricular%20adaptation%20to%20exercise%20in%20patients%20with%20repaired%20tetralogy%20of%20Fallot%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Paul%22%2C%22lastName%22%3A%22Habert%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Zakarya%22%2C%22lastName%22%3A%22Bentatou%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Philippe%22%2C%22lastName%22%3A%22Aldebert%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Mathieu%22%2C%22lastName%22%3A%22Finas%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Axel%22%2C%22lastName%22%3A%22Bartoli%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Laurence%22%2C%22lastName%22%3A%22Bal%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alain%22%2C%22lastName%22%3A%22Lalande%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Frank%22%2C%22lastName%22%3A%22Kober%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Monique%22%2C%22lastName%22%3A%22Bernard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Alexis%22%2C%22lastName%22%3A%22Jacquier%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%3A%20The%20aim%20of%20our%20study%20was%20to%20evaluate%20the%20feasibility%20of%20exercise%20cardiac%20magnetic%20resonance%20%28CMR%29%20in%20patients%20with%20repaired%20tetralogy%20of%20Fallot%20%28RTOF%29%20and%20to%20assess%20right%20and%20left%20ventricular%20adaptation%20and%20aortic%20wall%20response%20to%20exercise%20in%20comparison%20with%20volunteers.%5CnMETHODS%3A%2011%20RTOF%20and%2011%20volunteers%20underwent%20prospective%20CMR%20at%20rest%20and%20during%20exercise.%20A%20supine%20bicycle%20ergometer%20was%20employed%20to%20reach%20twice%20the%20resting%20heart%20rate%20during%20continuous%20exercise%2C%20blood%20pressure%20and%20heart%20rate%20were%20recorded.%20Bi-ventricular%20parameters%20and%20aortic%20stiffness%20were%20assessed%20using%20accelerated%20cine%20sequences%20and%20flow-encoding%20CMR.%20A%20t-test%20was%20used%20to%20compare%20values%20between%20groups.%20A%20Mann%20Whitney%20test%20was%20used%20to%20compare%20values%20within%20groups.%5CnRESULTS%3A%20In%20RTOF%20both%20ventricles%20showed%20an%20impaired%20contractile%20reserve%20%28RVEF%20rest%2036.2%5Cu00b18.3%25%2C%20%2B1.3%5Cu00b13.9%25%20increase%20after%20exercise%3B%20LVEF%20rest%2053.8%5Cu00b16.1%25%2C%20%2B5.7%5Cu00b16.4%25%20increase%20after%20exercise%29%20compared%20to%20volunteers%20%28RVEF%20rest%2050.5%5Cu00b15.0%25%2C%20%2B10.4%5Cu00b17.1%25%20increase%20after%20exercise%2C%20p%20%3D%200.039%3B%20LVEF%20rest%2061.9%5Cu00b13.1%25%2C%20%2B12.2%5Cu00b14.7%25%20increase%20after%20exercise%2C%20p%20%3D%200.014%29.%20RTOF%20showed%20a%20reduced%20distensibility%20of%20the%20ascending%20aorta%20during%20exercise%20compared%20to%20volunteers%20%28RTOF%3A%203.4%5Cu00b11.9%2010-3.mmHg-1%20vs%20volunteers%3A%205.1%5Cu00b11.4%2010-3.mmHg-1%3B%20p%20%3D%200.027%29.%20Ascending%20aorta%20distensibility%20was%20correlated%20to%20cardiac%20work%20in%20the%20volunteers%20but%20not%20in%20RTOF.%5CnCONCLUSION%3A%20RTOF%20showed%20an%20impaired%20contractile%20reserve%20for%20both%20ventricles.%20The%20exercise%20unmasked%20a%20reduced%20distensibility%20of%20the%20ascending%20aorta%20in%20RTOF%2C%20which%20may%20be%20an%20early%20sign%20of%20increased%20aortic%20rigidity.%22%2C%22date%22%3A%222018%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1371%5C%2Fjournal.pone.0208749%22%2C%22ISSN%22%3A%221932-6203%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%225Z6CVJGB%22%2C%22KFZ6H27M%22%2C%22SK6VWU7K%22%2C%22B4FUISBZ%22%2C%22XTA6KS7L%22%2C%22BR9D2SS4%22%2C%22CXAMISN8%22%5D%2C%22dateModified%22%3A%222024-06-14T08%3A30%3A15Z%22%7D%7D%2C%7B%22key%22%3A%229EUN9NNG%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Bydder%20et%20al.%22%2C%22parsedDate%22%3A%222017-07-15%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BBydder%2C%20M.%2C%20Rapacchi%2C%20S.%2C%20Girard%2C%20O.%2C%20Guye%2C%20M.%20and%20Ranjeva%2C%20J.-P.%20%282017%29%20%26%23x201C%3BTrimmed%20autocalibrating%20k-space%20estimation%20based%20on%20structured%20matrix%20completion%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20Imaging%26lt%3B%5C%2Fi%26gt%3B%2C%2043%2C%20pp.%2088%26%23x2013%3B94.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.mri.2017.07.015%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.mri.2017.07.015%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Trimmed%20autocalibrating%20k-space%20estimation%20based%20on%20structured%20matrix%20completion%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Mark%22%2C%22lastName%22%3A%22Bydder%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Olivier%22%2C%22lastName%22%3A%22Girard%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Maxime%22%2C%22lastName%22%3A%22Guye%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jean-Philippe%22%2C%22lastName%22%3A%22Ranjeva%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20Parallel%20imaging%20allows%20the%20reconstruction%20of%20undersampled%20data%20from%20multiple%20coils.%20This%20provides%20a%20means%20to%20reject%20and%20regenerate%20corrupt%20data%20%28e.g.%20from%20motion%20artefact%29.%20The%20purpose%20of%20this%20work%20is%20to%20approach%20this%20problem%20using%20the%20SAKE%20parallel%20imaging%20method.%5CnTHEORY%20AND%20METHODS%3A%20Parallel%20imaging%20methods%20typically%20require%20calibration%20by%20fully%20sampling%20the%20center%20of%20k-space.%20This%20is%20a%20challenge%20in%20the%20presence%20of%20corrupted%20data%2C%20since%20the%20calibration%20data%20may%20be%20corrupted%20which%20leads%20to%20an%20errors-in-variables%20problem%20that%20cannot%20be%20solved%20by%20least%20squares%20or%20even%20iteratively%20reweighted%20least%20squares.%20The%20SAKE%20method%2C%20based%20on%20matrix%20completion%20and%20structured%20low%20rank%20approximation%2C%20was%20modified%20to%20detect%20and%20trim%20these%20errors%20from%20the%20data.%5CnRESULTS%3A%20Simulated%20and%20actual%20corrupted%20datasets%20were%20reconstructed%20with%20SAKE%2C%20the%20proposed%20approach%20and%20a%20more%20standard%20reconstruction%20method%20%28based%20on%20solving%20a%20linear%20equation%29%20with%20a%20data%20rejection%20criterion.%20The%20proposed%20approach%20was%20found%20to%20reduce%20artefacts%20considerably%20in%20comparison%20to%20the%20other%20two%20methods.%5CnCONCLUSION%3A%20SAKE%20with%20data%20trimming%20improves%20on%20previous%20methods%20for%20reconstructing%20images%20from%20grossly%20corrupted%20data.%22%2C%22date%22%3A%22Jul%2015%2C%202017%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.mri.2017.07.015%22%2C%22ISSN%22%3A%221873-5894%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%2274RX9758%22%2C%22UP3H3ICX%22%2C%22SK6VWU7K%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222023-11-23T14%3A14%3A11Z%22%7D%7D%2C%7B%22key%22%3A%22Q2NC3FAU%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Han%20et%20al.%22%2C%22parsedDate%22%3A%222017-04%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BHan%2C%20F.%2C%20Rapacchi%2C%20S.%20and%20Hu%2C%20P.%20%282017%29%20%26%23x201C%3BProspective%20cardiac%20motion%20self-gating%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BQuantitative%20Imaging%20in%20Medicine%20and%20Surgery%26lt%3B%5C%2Fi%26gt%3B%2C%207%282%29%2C%20pp.%20215%26%23x2013%3B226.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.21037%5C%2Fqims.2017.03.02%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.21037%5C%2Fqims.2017.03.02%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Prospective%20cardiac%20motion%20self-gating%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fei%22%2C%22lastName%22%3A%22Han%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Peng%22%2C%22lastName%22%3A%22Hu%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%3A%20To%20develop%20a%20prospective%20cardiac%20motion%20self-gating%20method%20that%20provides%20robust%20and%20accurate%20cardiac%20triggers%20in%20real%20time.%5CnMETHODS%3A%20The%20proposed%20self-gating%20method%20consists%20of%20an%20%26quot%3Bimaging%20mode%26quot%3B%20that%20acquires%20the%20k-space%20segments%20and%20a%20%26quot%3Bself-gating%20mode%26quot%3B%20that%20captures%20the%20cardiac%20motion%20by%20repeatedly%20sampling%20the%20k-space%20centerline.%20A%20training%20based%20principal%20component%20analysis%20algorithm%20is%20utilized%20to%20process%20the%20self-gating%20data%20where%20the%20projection%20onto%20the%20first%20principal%20component%20was%20used%20as%20the%20self-gating%20signal.%20Retrospective%20studies%20using%20a%20sequence%20with%20self-gating%20mode%20only%20was%20performed%20on%208%20healthy%20subjects%20to%20validate%20the%20accuracy%20and%20reliability%20of%20the%20self-gating%20triggers.%20Prospective%20studies%20using%20both%20ECG-gated%20and%20self-gated%20cardiac%20CINE%20sequences%20were%20conducted%20on%206%20healthy%20subjects%20to%20compare%20the%20image%20quality.%5CnRESULTS%3A%20Using%20the%20ECG%20as%20the%20reference%2C%20the%20proposed%20method%20was%20able%20to%20detect%20self-gating%20triggers%20within%20%5Cu00b110%20ms%20accuracy%20on%20all%208%20subjects%20in%20the%20retrospective%20study.%20The%20prospectively%20self-gated%20CINE%20sequence%20successfully%20detected%20100%25%20of%20the%20cardiac%20triggers%20and%20provided%20excellent%20CINE%20image%20quality%20without%20using%20ECG%20signals.%5CnCONCLUSIONS%3A%20The%20proposed%20cardiac%20self-gating%20method%20is%20a%20robust%20and%20accurate%20alternative%20to%20conventional%20ECG-based%20gating%20method%20for%20a%20number%20of%20cardiac%20MRI%20applications.%22%2C%22date%22%3A%22Apr%202017%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.21037%5C%2Fqims.2017.03.02%22%2C%22ISSN%22%3A%222223-4292%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222023-11-23T14%3A13%3A25Z%22%7D%7D%2C%7B%22key%22%3A%22ARQQ6W7R%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Zhou%20et%20al.%22%2C%22parsedDate%22%3A%222017-01%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BZhou%2C%20Z.%2C%20Han%2C%20F.%2C%20Rapacchi%2C%20S.%2C%20Nguyen%2C%20K.-L.%2C%20Brunengraber%2C%20D.Z.%2C%20Kim%2C%20G.-H.J.%2C%20Finn%2C%20J.P.%20and%20Hu%2C%20P.%20%282017%29%20%26%23x201C%3BAccelerated%20ferumoxytol-enhanced%204D%20multiphase%2C%20steady-state%20imaging%20with%20contrast%20enhancement%20%28MUSIC%29%20cardiovascular%20MRI%3A%20validation%20in%20pediatric%20congenital%20heart%20disease%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BNMR%20in%20biomedicine%26lt%3B%5C%2Fi%26gt%3B%2C%2030%281%29.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fnbm.3663%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fnbm.3663%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Accelerated%20ferumoxytol-enhanced%204D%20multiphase%2C%20steady-state%20imaging%20with%20contrast%20enhancement%20%28MUSIC%29%20cardiovascular%20MRI%3A%20validation%20in%20pediatric%20congenital%20heart%20disease%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ziwu%22%2C%22lastName%22%3A%22Zhou%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fei%22%2C%22lastName%22%3A%22Han%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Kim-Lien%22%2C%22lastName%22%3A%22Nguyen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Daniel%20Z.%22%2C%22lastName%22%3A%22Brunengraber%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Grace-Hyun%20J.%22%2C%22lastName%22%3A%22Kim%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22J.%20Paul%22%2C%22lastName%22%3A%22Finn%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Peng%22%2C%22lastName%22%3A%22Hu%22%7D%5D%2C%22abstractNote%22%3A%22The%20purpose%20of%20this%20work%20was%20to%20validate%20a%20parallel%20imaging%20%28PI%29%20and%20compressed%20sensing%20%28CS%29%20combined%20reconstruction%20method%20for%20a%20recently%20proposed%204D%20non-breath-held%2C%20multiphase%2C%20steady-state%20imaging%20technique%20%28MUSIC%29%20cardiovascular%20MRI%20in%20a%20cohort%20of%20pediatric%20congenital%20heart%20disease%20patients.%20We%20implemented%20a%20graphics%20processing%20unit%20accelerated%20CS-PI%20combined%20reconstruction%20method%20and%20applied%20it%20in%2013%20pediatric%20patients%20who%20underwent%20cardiovascular%20MRI%20after%20ferumoxytol%20administration.%20Conventional%20breath-held%20contrast-enhanced%20magnetic%20resonance%20angiography%20%28CE-MRA%29%20was%20first%20performed%20during%20the%20first%20pass%20of%20ferumoxytol%20injection%2C%20followed%20by%20the%20original%20MUSIC%20and%20the%20proposed%20CS-PI%20MUSIC%20during%20the%20steady-state%20distribution%20phase%20of%20ferumoxytol.%20Qualities%20of%20acquired%20images%20were%20then%20evaluated%20using%20a%20four-point%20scale.%20Left%20ventricular%20volumes%20and%20ejection%20fractions%20calculated%20from%20the%20original%20MUSIC%20and%20the%20CS-PI%20MUSIC%20were%20also%20compared%20with%20conventional%20multi-slice%202D%20cardiac%20cine%20MRI.%20The%20proposed%20CS-PI%20MUSIC%20reduced%20the%20imaging%20time%20of%20the%20MUSIC%20acquisition%20to%204.6%5Cu00a0%5Cu00b1%5Cu00a00.4%5Cu00a0min%20from%208.9%5Cu00a0%5Cu00b1%5Cu00a01.2%5Cu00a0min.%20Computationally%20intensive%20image%20reconstruction%20was%20completed%20within%205%5Cu00a0min%20without%20interruption%20of%20sequential%20clinical%20scans.%20The%20proposed%20method%20%28mean%203.3-4.0%29%20provided%20image%20quality%20comparable%20to%20that%20of%20the%20original%20MUSIC%20%283.2-4.0%29%20%28all%20P%5Cu00a0%5Cu2265%5Cu00a00.42%29%2C%20and%20better%20than%20conventional%20breath-held%20first-pass%20CE-MRA%20%281.1-3.3%29%20for%2013%20anatomical%20structures%20%28all%20P%20%5Cu2264%200.0014%29%20with%20good%20inter-observer%20agreement%20%28%5Cu03ba%5Cu00a0%26gt%3B%5Cu00a00.46%29.%20The%20calculated%20ventricular%20volumes%20and%20ejection%20fractions%20from%20both%20original%20MUSIC%20%28r%5Cu00a0%26gt%3B%5Cu00a00.90%29%20and%20CS-PI%20MUSIC%20%28r%5Cu00a0%26gt%3B%5Cu00a00.85%29%20correlated%20well%20with%202D%20cine%20imaging.%20In%20conclusion%2C%20PI%20and%20CS%20were%20successfully%20incorporated%20into%20the%204D%20MUSIC%20acquisition%20to%20further%20reduce%20scan%20time%20by%20approximately%2050%25%20while%20maintaining%20highly%20comparable%20image%20quality%20in%20a%20clinically%20practical%20reconstruction%20time.%22%2C%22date%22%3A%22Jan%202017%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1002%5C%2Fnbm.3663%22%2C%22ISSN%22%3A%221099-1492%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222024-06-14T08%3A28%3A55Z%22%7D%7D%2C%7B%22key%22%3A%22BH6K98GC%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Shao%20et%20al.%22%2C%22parsedDate%22%3A%222016-02%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BShao%2C%20J.%2C%20Rapacchi%2C%20S.%2C%20Nguyen%2C%20K.-L.%20and%20Hu%2C%20P.%20%282016%29%20%26%23x201C%3BMyocardial%20T1%20mapping%20at%203.0%20tesla%20using%20an%20inversion%20recovery%20spoiled%20gradient%20echo%20readout%20and%20bloch%20equation%20simulation%20with%20slice%20profile%20correction%20%28BLESSPC%29%20T1%20estimation%20algorithm%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BJournal%20of%20magnetic%20resonance%20imaging%3A%20JMRI%26lt%3B%5C%2Fi%26gt%3B%2C%2043%282%29%2C%20pp.%20414%26%23x2013%3B425.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fjmri.24999%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fjmri.24999%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Myocardial%20T1%20mapping%20at%203.0%20tesla%20using%20an%20inversion%20recovery%20spoiled%20gradient%20echo%20readout%20and%20bloch%20equation%20simulation%20with%20slice%20profile%20correction%20%28BLESSPC%29%20T1%20estimation%20algorithm%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jiaxin%22%2C%22lastName%22%3A%22Shao%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Kim-Lien%22%2C%22lastName%22%3A%22Nguyen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Peng%22%2C%22lastName%22%3A%22Hu%22%7D%5D%2C%22abstractNote%22%3A%22BACKGROUND%3A%20To%20develop%20an%20accurate%20and%20precise%20myocardial%20T1%20mapping%20technique%20using%20an%20inversion%20recovery%20spoiled%20gradient%20echo%20readout%20at%203.0%20Tesla%20%28T%29.%5CnTHEORY%20AND%20METHODS%3A%20The%20modified%20Look-Locker%20inversion-recovery%20%28MOLLI%29%20sequence%20was%20modified%20to%20use%20fast%20low%20angle%20shot%20%28FLASH%29%20readout%2C%20incorporating%20a%20BLESSPC%20%28Bloch%20Equation%20Simulation%20with%20Slice%20Profile%20Correction%29%20T1%20estimation%20algorithm%2C%20for%20accurate%20myocardial%20T1%20mapping.%20The%20FLASH-MOLLI%20with%20BLESSPC%20fitting%20was%20compared%20with%20different%20approaches%20and%20sequences%20with%20regards%20to%20T1%20estimation%20accuracy%2C%20precision%20and%20image%20artifact%20based%20on%20simulation%2C%20phantom%20studies%2C%20and%20in%20vivo%20studies%20of%2010%20healthy%20volunteers%20and%20three%20patients%20at%203.0%20Tesla.%5CnRESULTS%3A%20The%20FLASH-MOLLI%20with%20BLESSPC%20fitting%20yields%20accurate%20T1%20estimation%20%28average%20error%5Cu2009%3D%5Cu2009-5.4%5Cu2009%5Cu00b1%5Cu200915.1%20ms%2C%20percentage%20error%5Cu2009%3D%5Cu2009-0.5%25%5Cu2009%5Cu00b1%5Cu20091.2%25%29%20for%20T1%20from%20236-1852%20ms%20and%20heart%20rate%20from%2040-100%20bpm%20in%20phantom%20studies.%20The%20FLASH-MOLLI%20sequence%20prevented%20off-resonance%20artifacts%20in%20all%2010%20healthy%20volunteers%20at%203.0T.%20In%20vivo%2C%20there%20was%20no%20significant%20difference%20between%20FLASH-MOLLI-derived%20myocardial%20T1%20values%20and%20%26quot%3BShMOLLI%2BIE%26quot%3B%20derived%20values%20%281458.9%5Cu2009%5Cu00b1%5Cu200920.9%20ms%20versus%201464.1%5Cu2009%5Cu00b1%5Cu20096.8%20ms%2C%20P%5Cu2009%3D%5Cu20090.50%29%3B%20However%2C%20the%20average%20precision%20by%20FLASH-MOLLI%20was%20significantly%20better%20than%20that%20generated%20by%20%26quot%3BShMOLLI%2BIE%26quot%3B%20%281.84%5Cu2009%5Cu00b1%5Cu20090.36%25%20variance%20versus%203.57%5Cu2009%5Cu00b1%5Cu20090.94%25%2C%20P%5Cu2009%26lt%3B%5Cu20090.001%29.%5CnCONCLUSION%3A%20The%20FLASH-MOLLI%20with%20BLESSPC%20fitting%20yields%20accurate%20and%20precise%20T1%20estimation%2C%20and%20eliminates%20banding%20artifacts%20associated%20with%20bSSFP%20at%203.0T.%20J.%20Magn.%20Reson.%20Imaging%202016%3B43%3A414-425.%22%2C%22date%22%3A%22Feb%202016%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1002%5C%2Fjmri.24999%22%2C%22ISSN%22%3A%221522-2586%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222016-03-29T15%3A00%3A36Z%22%7D%7D%2C%7B%22key%22%3A%22VTVMMS4G%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22lastModifiedByUser%22%3A%7B%22id%22%3A1495222%2C%22username%22%3A%22crmbmlab%22%2C%22name%22%3A%22crmbmlab%22%2C%22links%22%3A%7B%22alternate%22%3A%7B%22href%22%3A%22https%3A%5C%2F%5C%2Fwww.zotero.org%5C%2Fcrmbmlab%22%2C%22type%22%3A%22text%5C%2Fhtml%22%7D%7D%7D%2C%22creatorSummary%22%3A%22Rashid%20et%20al.%22%2C%22parsedDate%22%3A%222016-02%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BRashid%2C%20S.%2C%20Rapacchi%2C%20S.%2C%20Shivkumar%2C%20K.%2C%20Plotnik%2C%20A.%2C%20Finn%2C%20J.P.%20and%20Hu%2C%20P.%20%282016%29%20%26%23x201C%3BModified%20wideband%20three-dimensional%20late%20gadolinium%20enhancement%20MRI%20for%20patients%20with%20implantable%20cardiac%20devices%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2075%282%29%2C%20pp.%20572%26%23x2013%3B584.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.25601%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.25601%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Modified%20wideband%20three-dimensional%20late%20gadolinium%20enhancement%20MRI%20for%20patients%20with%20implantable%20cardiac%20devices%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Shams%22%2C%22lastName%22%3A%22Rashid%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Kalyanam%22%2C%22lastName%22%3A%22Shivkumar%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Adam%22%2C%22lastName%22%3A%22Plotnik%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22J.%20Paul%22%2C%22lastName%22%3A%22Finn%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Peng%22%2C%22lastName%22%3A%22Hu%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20study%20the%20effects%20of%20cardiac%20devices%20on%20three-dimensional%20%283D%29%20late%20gadolinium%20enhancement%20%28LGE%29%20MRI%20and%20to%20develop%20a%203D%20LGE%20protocol%20for%20implantable%20cardioverter%20defibrillator%20%28ICD%29%20patients%20with%20reduced%20image%20artifacts.%5CnTHEORY%20AND%20METHODS%3A%20The%203D%20LGE%20sequence%20was%20modified%20by%20implementing%20a%20wideband%20inversion%20pulse%2C%20which%20reduces%20hyperintensity%20artifacts%2C%20and%20by%20increasing%20bandwidth%20of%20the%20excitation%20pulse.%20The%20modified%20wideband%203D%20LGE%20sequence%20was%20tested%20in%20phantoms%20and%20evaluated%20in%20six%20volunteers%20and%20five%20patients%20with%20ICDs.%5CnRESULTS%3A%20Phantom%20and%20in%20vivo%20studies%20results%20demonstrated%20extended%20signal%20void%20and%20ripple%20artifacts%20in%203D%20LGE%20that%20were%20associated%20with%20ICDs.%20The%20reason%20for%20these%20artifacts%20was%20slab%20profile%20distortion%20and%20the%20subsequent%20aliasing%20in%20the%20slice-encoding%20direction.%20The%20modified%20wideband%203D%20LGE%20provided%20significantly%20reduced%20ripple%20artifacts%20than%203D%20LGE%20with%20wideband%20inversion%20only.%20Comparison%20of%203D%20and%202D%20LGE%20images%20demonstrated%20improved%20spatial%20resolution%20of%20the%20heart%20using%203D%20LGE.%5CnCONCLUSION%3A%20Increased%20bandwidth%20of%20the%20inversion%20and%20excitation%20pulses%20can%20significantly%20reduce%20image%20artifacts%20associated%20with%20ICDs.%20Our%20modified%20wideband%203D%20LGE%20protocol%20can%20be%20readily%20used%20for%20imaging%20patients%20with%20ICDs%20given%20appropriate%20safety%20guidelines%20are%20followed.%20Magn%20Reson%20Med%2075%3A572-584%2C%202016.%20%5Cu00a9%202015%20Wiley%20Periodicals%2C%20Inc.%22%2C%22date%22%3A%22Feb%202016%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.25601%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222016-03-29T14%3A59%3A19Z%22%7D%7D%2C%7B%22key%22%3A%22CDV6WUZ8%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22lastModifiedByUser%22%3A%7B%22id%22%3A1495222%2C%22username%22%3A%22crmbmlab%22%2C%22name%22%3A%22crmbmlab%22%2C%22links%22%3A%7B%22alternate%22%3A%7B%22href%22%3A%22https%3A%5C%2F%5C%2Fwww.zotero.org%5C%2Fcrmbmlab%22%2C%22type%22%3A%22text%5C%2Fhtml%22%7D%7D%7D%2C%22creatorSummary%22%3A%22Skelton%20et%20al.%22%2C%22parsedDate%22%3A%222016-01%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BSkelton%2C%20R.J.P.%2C%20Khoja%2C%20S.%2C%20Almeida%2C%20S.%2C%20Rapacchi%2C%20S.%2C%20Han%2C%20F.%2C%20Engel%2C%20J.%2C%20Zhao%2C%20P.%2C%20Hu%2C%20P.%2C%20Stanley%2C%20E.G.%2C%20Elefanty%2C%20A.G.%2C%20Kwon%2C%20M.%2C%20Elliott%2C%20D.A.%20and%20Ardehali%2C%20R.%20%282016%29%20%26%23x201C%3BMagnetic%20Resonance%20Imaging%20of%20Iron%20Oxide-Labeled%20Human%20Embryonic%20Stem%20Cell-Derived%20Cardiac%20Progenitors%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BStem%20Cells%20Translational%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%205%281%29%2C%20pp.%2067%26%23x2013%3B74.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.5966%5C%2Fsctm.2015-0077%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.5966%5C%2Fsctm.2015-0077%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Magnetic%20Resonance%20Imaging%20of%20Iron%20Oxide-Labeled%20Human%20Embryonic%20Stem%20Cell-Derived%20Cardiac%20Progenitors%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Rhys%20J.%20P.%22%2C%22lastName%22%3A%22Skelton%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Suhail%22%2C%22lastName%22%3A%22Khoja%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Shone%22%2C%22lastName%22%3A%22Almeida%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fei%22%2C%22lastName%22%3A%22Han%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22James%22%2C%22lastName%22%3A%22Engel%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Peng%22%2C%22lastName%22%3A%22Zhao%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Peng%22%2C%22lastName%22%3A%22Hu%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Edouard%20G.%22%2C%22lastName%22%3A%22Stanley%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Andrew%20G.%22%2C%22lastName%22%3A%22Elefanty%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Murray%22%2C%22lastName%22%3A%22Kwon%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22David%20A.%22%2C%22lastName%22%3A%22Elliott%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Reza%22%2C%22lastName%22%3A%22Ardehali%22%7D%5D%2C%22abstractNote%22%3A%22Given%20the%20limited%20regenerative%20capacity%20of%20the%20heart%2C%20cellular%20therapy%20with%20stem%20cell-derived%20cardiac%20cells%20could%20be%20a%20potential%20treatment%20for%20patients%20with%20heart%20disease.%20However%2C%20reliable%20imaging%20techniques%20to%20longitudinally%20assess%20engraftment%20of%20the%20transplanted%20cells%20are%20scant.%20To%20address%20this%20issue%2C%20we%20used%20ferumoxytol%20as%20a%20labeling%20agent%20of%20human%20embryonic%20stem%20cell-derived%20cardiac%20progenitor%20cells%20%28hESC-CPCs%29%20to%20facilitate%20tracking%20by%20magnetic%20resonance%20imaging%20%28MRI%29%20in%20a%20large%20animal%20model.%20Differentiating%20hESCs%20were%20exposed%20to%20ferumoxytol%20at%20different%20time%20points%20and%20varying%20concentrations.%20We%20determined%20that%20treatment%20with%20ferumoxytol%20at%20300%20%5Cu03bcg%5C%2Fml%20on%20day%200%20of%20cardiac%20differentiation%20offered%20adequate%20cell%20viability%20and%20signal%20intensity%20for%20MRI%20detection%20without%20compromising%20further%20differentiation%20into%20definitive%20cardiac%20lineages.%20Labeled%20hESC-CPCs%20were%20transplanted%20by%20open%20surgical%20methods%20into%20the%20left%20ventricular%20free%20wall%20of%20uninjured%20pig%20hearts%20and%20imaged%20both%20ex%20vivo%20and%20in%20vivo.%20Comprehensive%20T2%2A-weighted%20images%20were%20obtained%20immediately%20after%20transplantation%20and%2040%20days%20later%20before%20termination.%20The%20localization%20and%20dispersion%20of%20labeled%20cells%20could%20be%20effectively%20imaged%20and%20tracked%20at%20days%200%20and%2040%20by%20MRI.%20Thus%2C%20under%20the%20described%20conditions%2C%20ferumoxytol%20can%20be%20used%20as%20a%20long-term%2C%20differentiation-neutral%20cell-labeling%20agent%20to%20track%20transplanted%20hESC-CPCs%20in%20vivo%20using%20MRI.%5CnSIGNIFICANCE%3A%20The%20development%20of%20a%20safe%20and%20reproducible%20in%20vivo%20imaging%20technique%20to%20track%20the%20fate%20of%20transplanted%20human%20embryonic%20stem%20cell-derived%20cardiac%20progenitor%20cells%20%28hESC-CPCs%29%20is%20a%20necessary%20step%20to%20clinical%20translation.%20An%20iron%20oxide%20nanoparticle%20%28ferumoxytol%29-based%20approach%20was%20used%20for%20cell%20labeling%20and%20subsequent%20in%20vivo%20magnetic%20resonance%20imaging%20monitoring%20of%20hESC-CPCs%20transplanted%20into%20uninjured%20pig%20hearts.%20The%20present%20results%20demonstrate%20the%20use%20of%20ferumoxytol%20labeling%20and%20imaging%20techniques%20in%20tracking%20the%20location%20and%20dispersion%20of%20cell%20grafts%2C%20highlighting%20its%20utility%20in%20future%20cardiac%20stem%20cell%20therapy%20trials.%22%2C%22date%22%3A%22Jan%202016%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.5966%5C%2Fsctm.2015-0077%22%2C%22ISSN%22%3A%222157-6564%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222016-03-29T14%3A58%3A17Z%22%7D%7D%2C%7B%22key%22%3A%226W5WHIZ9%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Rapacchi%20et%20al.%22%2C%22parsedDate%22%3A%222015-11%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BRapacchi%2C%20S.%2C%20Smith%2C%20R.X.%2C%20Wang%2C%20Y.%2C%20Yan%2C%20L.%2C%20Sigalov%2C%20V.%2C%20Krasileva%2C%20K.E.%2C%20Karpouzas%2C%20G.%2C%20Plotnik%2C%20A.%2C%20Sayre%2C%20J.%2C%20Hernandez%2C%20E.%2C%20Verma%2C%20A.%2C%20Burkly%2C%20L.%2C%20Wisniacki%2C%20N.%2C%20Torrington%2C%20J.%2C%20He%2C%20X.%2C%20Hu%2C%20P.%2C%20Chiao%2C%20P.-C.%20and%20Wang%2C%20D.J.J.%20%282015%29%20%26%23x201C%3BTowards%20the%20identification%20of%20multi-parametric%20quantitative%20MRI%20biomarkers%20in%20lupus%20nephritis%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20Imaging%26lt%3B%5C%2Fi%26gt%3B%2C%2033%289%29%2C%20pp.%201066%26%23x2013%3B1074.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.mri.2015.06.019%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1016%5C%2Fj.mri.2015.06.019%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Towards%20the%20identification%20of%20multi-parametric%20quantitative%20MRI%20biomarkers%20in%20lupus%20nephritis%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Robert%20X.%22%2C%22lastName%22%3A%22Smith%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Yi%22%2C%22lastName%22%3A%22Wang%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Lirong%22%2C%22lastName%22%3A%22Yan%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Victor%22%2C%22lastName%22%3A%22Sigalov%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Kate%20E.%22%2C%22lastName%22%3A%22Krasileva%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22George%22%2C%22lastName%22%3A%22Karpouzas%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Adam%22%2C%22lastName%22%3A%22Plotnik%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22James%22%2C%22lastName%22%3A%22Sayre%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Elizabeth%22%2C%22lastName%22%3A%22Hernandez%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ajay%22%2C%22lastName%22%3A%22Verma%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Linda%22%2C%22lastName%22%3A%22Burkly%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Nicolas%22%2C%22lastName%22%3A%22Wisniacki%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Jaime%22%2C%22lastName%22%3A%22Torrington%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Xiang%22%2C%22lastName%22%3A%22He%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Peng%22%2C%22lastName%22%3A%22Hu%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ping-Chun%22%2C%22lastName%22%3A%22Chiao%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Danny%20J.%20J.%22%2C%22lastName%22%3A%22Wang%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20identify%20potential%20biomarkers%20of%20the%20renal%20impairment%20in%20lupus%20nephritis%20using%20a%20multi-parametric%20renal%20quantitative%20MRI%20%28qMRI%29%20protocol%20including%20diffusion%20weighted%20imaging%20%28DWI%29%2C%20blood%20oxygen%20level%20dependent%20%28BOLD%29%2C%20arterial%20spin%20labeling%20%28ASL%29%20and%20T1rho%20MRI%20between%20a%20cohort%20of%20healthy%20volunteers%20and%20lupus%20nephritis%20%28LN%29%20patients.%5CnMATERIALS%20AND%20METHODS%3A%20The%20renal%20qMRI%20protocol%20was%20performed%20twice%20with%20repositioning%20in%20between%20on%2010%20LN%20patients%20and%2010%20matched%20controls%20at%201.5%20T.%20Navigator-gated%20and%20breath-hold%20acquisitions%20followed%20by%20non-rigid%20image%20registration%20were%20used%20to%20control%20respiratory%20motion.%20The%20repeatability%20of%20the%204%20MRI%20modalities%20was%20evaluated%20with%20the%20intra-class%20correlation%20coefficient%20%28ICC%29%20and%20within-subject%20coefficient%20of%20variation%20%28wsCV%29.%20Unpaired%20t-test%20and%20stepwise%20logistic%20regression%20were%20carried%20out%20to%20evaluate%20qMRI%20parameters%20between%20the%20LN%20and%20control%20groups.%5CnRESULTS%3A%20The%20reproducibility%20of%20the%204%20qMRI%20modalities%20ranged%20from%20moderate%20to%20good%20%28ICC%3D0.4-0.91%2C%20wsCV%5Cu226412%25%29%20with%20a%20few%20exceptions.%20T1rho%20MRI%20and%20ASL%20renal%20blood%20flow%20%28RBF%29%20demonstrated%20significant%20differences%20between%20the%20LN%20and%20control%20groups.%20Stepwise%20logistic%20regression%20yielded%20only%20one%20significant%20parameter%20%28medullar%20T1rho%29%20in%20differentiating%20LN%20from%20control%20groups%20with%2095%25%20accuracy.%5CnCONCLUSION%3A%20A%20reasonable%20degree%20of%20test-retest%20repeatability%20and%20accuracy%20of%20a%20multi-parametric%20renal%20qMRI%20protocol%20has%20been%20demonstrated%20in%20healthy%20volunteers%20and%20LN%20subjects.%20T1rho%20and%20ASL%20RBF%20are%20promising%20imaging%20biomarkers%20of%20LN.%22%2C%22date%22%3A%22Nov%202015%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1016%5C%2Fj.mri.2015.06.019%22%2C%22ISSN%22%3A%221873-5894%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222024-01-29T09%3A35%3A53Z%22%7D%7D%2C%7B%22key%22%3A%22MENQ9GEV%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Han%20et%20al.%22%2C%22parsedDate%22%3A%222015-10%22%2C%22numChildren%22%3A1%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BHan%2C%20F.%2C%20Rapacchi%2C%20S.%2C%20Khan%2C%20S.%2C%20Ayad%2C%20I.%2C%20Salusky%2C%20I.%2C%20Gabriel%2C%20S.%2C%20Plotnik%2C%20A.%2C%20Finn%2C%20J.P.%20and%20Hu%2C%20P.%20%282015%29%20%26%23x201C%3BFour-dimensional%2C%20multiphase%2C%20steady-state%20imaging%20with%20contrast%20enhancement%20%28MUSIC%29%20in%20the%20heart%3A%20a%20feasibility%20study%20in%20children%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%2C%2074%284%29%2C%20pp.%201042%26%23x2013%3B1049.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.25491%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.25491%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Four-dimensional%2C%20multiphase%2C%20steady-state%20imaging%20with%20contrast%20enhancement%20%28MUSIC%29%20in%20the%20heart%3A%20a%20feasibility%20study%20in%20children%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fei%22%2C%22lastName%22%3A%22Han%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Sarah%22%2C%22lastName%22%3A%22Khan%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ihab%22%2C%22lastName%22%3A%22Ayad%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Isidro%22%2C%22lastName%22%3A%22Salusky%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Simon%22%2C%22lastName%22%3A%22Gabriel%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Adam%22%2C%22lastName%22%3A%22Plotnik%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22J.%20Paul%22%2C%22lastName%22%3A%22Finn%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Peng%22%2C%22lastName%22%3A%22Hu%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20To%20develop%20a%20technique%20for%20high%20resolution%2C%20four-dimensional%20%284D%29%2C%20multiphase%2C%20steady-state%20imaging%20with%20contrast%20enhancement%20%28MUSIC%29%20in%20children%20with%20complex%20congenital%20heart%20disease.%5CnMETHODS%3A%20Eight%20pediatric%20patients%20underwent%20cardiovascular%20MRI%20with%20controlled%20mechanical%20ventilation%20after%20ferumoxytol%20administration.%20Breath-held%20contrast-enhanced%20MRA%20%28CE-MRA%29%20was%20performed%20during%20the%20first-pass%20and%20delayed%20phases%20of%20ferumoxytol%2C%20followed%20by%20a%20respiratory%20gated%2C%204D%20MUSIC%20acquisition%20during%20the%20steady%20state%20distribution%20phase%20of%20ferumoxytol.%20The%20subjective%20image%20quality%20and%20image%20sharpness%20were%20evaluated.%20Assessment%20of%20ventricular%20volumes%20based%20on%204D%20MUSIC%20was%20compared%20with%20those%20based%20on%20multislice%202D%20cardiac%20cine%20MRI.%5CnRESULTS%3A%20The%204D%20MUSIC%20technique%20provided%20cardiac-phase-resolved%20%2865-95%20ms%20temporal%20resolution%29%20and%20higher%20spatial%20resolution%20%280.6-0.9%20mm%20isotropic%29%20images%20than%20previously%20achievable%20using%20first-pass%20CE-MRA%20or%202D%20cardiac%20cine.%20When%20compared%20with%20Ferumoxytol-based%20first-pass%20CE-MRA%2C%20the%204D%20MUSIC%20provided%20sharper%20images%20and%20better%20definition%20of%20the%20coronary%20arteries%2C%20aortic%20root%2C%20myocardium%2C%20and%20pulmonary%20trunk%20%28P%5Cu2009%26lt%3B%5Cu20090.05%20for%20all%29.%20The%20ventricular%20volume%20measurements%20were%20in%20good%20agreement%20between%204D%20MUSIC%20and%202D%20cine%20%28concordance%20correlation%20coefficient%20%26gt%3B0.95%29.%5CnCONCLUSION%3A%20The%204D%20MUSIC%20technique%20may%20represent%20a%20new%20paradigm%20in%20MR%20evaluation%20of%20cardiovascular%20anatomy%20and%20function%20in%20children%20with%20complex%20congenital%20heart%20disease.%22%2C%22date%22%3A%22Oct%202015%22%2C%22language%22%3A%22eng%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.25491%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%5D%2C%22dateModified%22%3A%222022-02-24T14%3A30%3A44Z%22%7D%7D%2C%7B%22key%22%3A%22AXUKPKQH%22%2C%22library%22%3A%7B%22id%22%3A180164%7D%2C%22meta%22%3A%7B%22creatorSummary%22%3A%22Han%20et%20al.%22%2C%22parsedDate%22%3A%222015-08-04%22%2C%22numChildren%22%3A2%7D%2C%22bib%22%3A%22%26lt%3Bdiv%20class%3D%26quot%3Bcsl-bib-body%26quot%3B%20style%3D%26quot%3Bline-height%3A%201.35%3B%20%26quot%3B%26gt%3B%5Cn%20%20%26lt%3Bdiv%20class%3D%26quot%3Bcsl-entry%26quot%3B%26gt%3BHan%2C%20F.%2C%20Zhou%2C%20Z.%2C%20Rapacchi%2C%20S.%2C%20Nguyen%2C%20K.-L.%2C%20Finn%2C%20J.P.%20and%20Hu%2C%20P.%20%282015%29%20%26%23x201C%3BSegmented%20golden%20ratio%20radial%20reordering%20with%20variable%20temporal%20resolution%20for%20dynamic%20cardiac%20MRI%2C%26%23x201D%3B%20%26lt%3Bi%26gt%3BMagnetic%20Resonance%20in%20Medicine%26lt%3B%5C%2Fi%26gt%3B%20%5BPreprint%5D.%20Available%20at%3A%20%26lt%3Ba%20class%3D%26%23039%3Bzp-DOIURL%26%23039%3B%20href%3D%26%23039%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.25861%26%23039%3B%26gt%3Bhttps%3A%5C%2F%5C%2Fdoi.org%5C%2F10.1002%5C%2Fmrm.25861%26lt%3B%5C%2Fa%26gt%3B.%26lt%3B%5C%2Fdiv%26gt%3B%5Cn%26lt%3B%5C%2Fdiv%26gt%3B%22%2C%22data%22%3A%7B%22itemType%22%3A%22journalArticle%22%2C%22title%22%3A%22Segmented%20golden%20ratio%20radial%20reordering%20with%20variable%20temporal%20resolution%20for%20dynamic%20cardiac%20MRI%22%2C%22creators%22%3A%5B%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Fei%22%2C%22lastName%22%3A%22Han%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Ziwu%22%2C%22lastName%22%3A%22Zhou%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Stanislas%22%2C%22lastName%22%3A%22Rapacchi%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Kim-Lien%22%2C%22lastName%22%3A%22Nguyen%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22J.%20Paul%22%2C%22lastName%22%3A%22Finn%22%7D%2C%7B%22creatorType%22%3A%22author%22%2C%22firstName%22%3A%22Peng%22%2C%22lastName%22%3A%22Hu%22%7D%5D%2C%22abstractNote%22%3A%22PURPOSE%3A%20Golden%20ratio%20%28GR%29%20radial%20reordering%20allows%20for%20retrospective%20choice%20of%20temporal%20resolution%20by%20providing%20a%20near-uniform%20k-space%20sampling%20within%20any%20reconstruction%20window.%20However%2C%20when%20applying%20GR%20to%20electrocardiogram%20%28ECG%29-gated%20cardiac%20imaging%2C%20the%20k-space%20coverage%20may%20not%20be%20as%20uniform%20because%20a%20single%20reconstruction%20window%20is%20broken%20into%20several%20temporally%20isolated%20ones.%20The%20goal%20of%20this%20study%20was%20to%20investigate%20the%20image%20artifacts%20caused%20by%20applying%20GR%20to%20ECG-gated%20cardiac%20imaging%20and%20to%20propose%20a%20segmented%20GR%20method%20to%20address%20this%20issue.%5CnMETHODS%3A%20Computer%20simulation%20and%20phantom%20experiments%20were%20used%20to%20evaluate%20the%20image%20artifacts%20resulting%20from%20three%20k-space%20sampling%20patterns%20%28ie%2C%20uniform%20radial%2C%20conventional%20GR%2C%20and%20segmented%20GR%29.%20Two-%20and%20three-dimensional%20cardiac%20cine%20images%20were%20acquired%20in%20seven%20healthy%20subjects.%20Imaging%20artifacts%20due%20to%20k-space%20sampling%20nonuniformity%20were%20graded%20on%20a%205-point%20scale%20by%20an%20experienced%20cardiac%20imaging%20reader.%5CnRESULTS%3A%20Segmented%20GR%20provides%20more%20uniform%20k-space%20sampling%20that%20is%20independent%20of%20heart-rate%20variation%20than%20conventional%20GR.%20Cardiac%20cine%20images%20using%20segmented%20GR%20have%20significantly%20higher%20and%20more%20reliable%20image%20quality%20than%20conventional%20GR.%5CnCONCLUSION%3A%20Segmented%20GR%20successfully%20addresses%20the%20nonuniform%20sampling%20that%20occurs%20with%20combining%20conventional%20GR%20with%20ECG%20gating.%20This%20technique%20can%20potentially%20be%20applied%20to%20any%20ECG-gated%20cardiac%20imaging%20application%20to%20allow%20for%20retrospective%20selection%20of%20a%20reconstruction%20window.%20Magn%20Reson%20Med%2C%202015.%20%5Cu00a9%202015%20Wiley%20Periodicals%2C%20Inc.%22%2C%22date%22%3A%22Aug%204%2C%202015%22%2C%22language%22%3A%22ENG%22%2C%22DOI%22%3A%2210.1002%5C%2Fmrm.25861%22%2C%22ISSN%22%3A%221522-2594%22%2C%22url%22%3A%22%22%2C%22collections%22%3A%5B%22SK6VWU7K%22%2C%22XTA6KS7L%22%5D%2C%22dateModified%22%3A%222022-02-26T13%3A09%3A43Z%22%7D%7D%5D%7D
Baudouard, M., Guivier-Curien, C., Rapacchi, S., Jacquier, A. and Deplano, V. (2025) “Aortic displacement reconstruction to build a patient-specific computational model,” Multidisciplinary Biomechanics Journal, 49th congress of the Société de Biomécanique(Cardiovascular and respiratory biomechanics). Available at: https://doi.org/10.46298/mbj.14485.
Licht, C., Ilicak, E., Boada, F.E., Guye, M., Zöllner, F.G., Schad, L.R. and Rapacchi, S. (2025) “A noise-robust post-processing pipeline for accelerated phase-cycled 23Na Multi-Quantum Coherences MRI,” Zeitschrift Fur Medizinische Physik, pp. S0939-3889(24)00117-X. Available at: https://doi.org/10.1016/j.zemedi.2024.12.004.
Hoesl, M.A.U., Schad, L.R. and Rapacchi, S. (2024) “Erratum to ‘Volumetric 23Na single and triple-quantum imaging at 7T: 3D-CRISTINA’ [Z Med Phys 32 (2022) 199-208],” Zeitschrift Fur Medizinische Physik, pp. S0939-3889(24)00076-X. Available at: https://doi.org/10.1016/j.zemedi.2024.07.008.
Omouri, A., Rapacchi, S., Duclos, J., Niddam, R., Bellemare, M.-E. and Pirró, N. (2024) “3D Observation of Pelvic Organs with Dynamic MRI Segmentation: A Bridge Toward Patient-Specific Models,” International Urogynecology Journal, 35(7), pp. 1389–1397. Available at: https://doi.org/10.1007/s00192-024-05817-0.
Daudé, P., Troalen, T., Mackowiak, A.L.C., Royer, E., Piccini, D., Yerly, J., Pfeuffer, J., Kober, F., Gouny, S.C., Bernard, M., Stuber, M., Bastiaansen, J.A.M. and Rapacchi, S. (2024) “Trajectory correction enables free-running chemical shift encoded imaging for accurate cardiac proton-density fat fraction quantification at 3T,” Journal of Cardiovascular Magnetic Resonance: Official Journal of the Society for Cardiovascular Magnetic Resonance, p. 101048. Available at: https://doi.org/10.1016/j.jocmr.2024.101048.
Cadour, F., Cour, A., Senlis, J., Rapacchi, S., Chennoufi, H., Michelin, P., McQuade, C., Demeyere, M. and Dacher, J.-N. (2024) “How to use MRI in cardiac disease with diastolic dysfunction?,” The British Journal of Radiology, p. tqae071. Available at: https://doi.org/10.1093/bjr/tqae071.
Licht, C., Reichert, S., Bydder, M., Zapp, J., Corella, S., Guye, M., Zöllner, F.G., Schad, L.R. and Rapacchi, S. (2024) “Low-rank reconstruction for simultaneous double half-echo 23Na and undersampled 23Na multi-quantum coherences MRI,” Magnetic Resonance in Medicine, 92(4), pp. 1440–1455. Available at: https://doi.org/10.1002/mrm.30132.
Licht, C., Reichert, S., Guye, M., Schad, L.R. and Rapacchi, S. (2024) “Multidimensional compressed sensing to advance 23Na multi-quantum coherences MRI,” Magnetic Resonance in Medicine, 91(3), pp. 926–941. Available at: https://doi.org/10.1002/mrm.29902.
Brui, E.A., Badrieva, Z., de Mayenne, C.-A., Rapacchi, S., Troalen, T. and Bendahan, D. (2024) “Mitigating slice cross-talk in multi-slice multi-echo spin echo T2 mapping,” Magnetic Resonance in Medicine, 91(5), pp. 2089–2103. Available at: https://doi.org/10.1002/mrm.29987.
Božić-Iven, M., Rapacchi, S., Tao, Q., Pierce, I., Thornton, G., Nitsche, C., Treibel, T.A., Schad, L.R. and Weingärtner, S. (2024) “Improved reproducibility for myocardial ASL: Impact of physiological and acquisition parameters,” Magnetic Resonance in Medicine, 91(1), pp. 118–132. Available at: https://doi.org/10.1002/mrm.29834.
Cadour, F., Sourdon, J. and Rapacchi, S. (2024) “Editorial for ‘Biventricular Dysfunction and Ventricular Interdependence in Patients With Pulmonary Hypertension: A 3.0-T Cardiac MRI Feature Tracking Study,’” Journal of Magnetic Resonance Imaging, 60(1), pp. 363–364. Available at: https://doi.org/10.1002/jmri.29092.
Daudé, P., Roussel, T., Troalen, T., Viout, P., Hernando, D., Guye, M., Kober, F., Confort Gouny, S., Bernard, M. and Rapacchi, S. (2024) “Comparative review of algorithms and methods for chemical-shift-encoded quantitative fat-water imaging,” Magnetic Resonance in Medicine, 91(2), pp. 741–759. Available at: https://doi.org/10.1002/mrm.29860.
Ogier, A.C., Rapacchi, S. and Bellemare, M.-E. (2023) “Four-dimensional reconstruction and characterization of bladder deformations,” Computer Methods and Programs in Biomedicine, 237, p. 107569. Available at: https://doi.org/10.1016/j.cmpb.2023.107569.
Cadour, F., Quemeneur, M., Biere, L., Donal, E., Bentatou, Z., Eicher, J.-C., Roubille, F., Lalande, A., Giorgi, R., Rapacchi, S., Cortaredona, S., Tradi, F., Bartoli, A., Willoteaux, S., Delahaye, F., Biene, S.M., Mangin, L., Ferrier, N., Dacher, J.-N., Bauer, F., Leurent, G., Lentz, P.-A., Kovacsik, H., Croisille, P., Thuny, F., Bernard, M., Guye, M., Furber, A., Habib, G. and Jacquier, A. (2023) “Prognostic value of cardiovascular magnetic resonance T1 mapping and extracellular volume fraction in nonischemic dilated cardiomyopathy,” Journal of Cardiovascular Magnetic Resonance: Official Journal of the Society for Cardiovascular Magnetic Resonance, 25(1), p. 7. Available at: https://doi.org/10.1186/s12968-023-00919-y.
Garcia Hernandez, A., Fau, P., Wojak, J., Mailleux, H., Benkreira, M., Rapacchi, S. and Adel, M. (2023) “Synthetic computed tomography generation for abdominal adaptive radiotherapy using low-field magnetic resonance imaging,” Physics and Imaging in Radiation Oncology, 25, p. 100425. Available at: https://doi.org/10.1016/j.phro.2023.100425.
Marage, L., Walker, P.-M., Boudet, J., Fau, P., Debuire, P., Clausse, E., Petitfils, A., Aubignac, L., Rapacchi, S. and Bessieres, I. (2022) “Characterisation of a split gradient coil design induced systemic imaging artefact on 0.35 T MR-linac systems,” Physics in Medicine & Biology, 68(1), p. 01NT03. Available at: https://doi.org/10.1088/1361-6560/aca876.
Silva-Verissimo, W., El Louali, F., Godio-Raboutet, Y., Leblond, L., Sourdon, J., Rapacchi, S. and Evin, M. (2022) “Traction mechanical characterization of porcine mitral valve annulus,” Journal of Biomechanics, 146, p. 111396. Available at: https://doi.org/10.1016/j.jbiomech.2022.111396.
Cadour, F., Cautela, J., Rapacchi, S., Varoquaux, A., Habert, P., Arnaud, F., Jacquier, A., Meilhac, A., Paganelli, F., Lalevée, N., Scemama, U. and Thuny, F. (2022) “Cardiac MRI Features and Prognostic Value in Immune Checkpoint Inhibitor–induced Myocarditis,” Radiology, 303(3), pp. 512–521. Available at: https://doi.org/10.1148/radiol.211765.
Hoesl, M.A.U., Schad, L.R. and Rapacchi, S. (2022) “Volumetric 23Na Single and Triple-Quantum Imaging at 7T: 3D-CRISTINA,” Zeitschrift für Medizinische Physik, 32(2), pp. 199–208. Available at: https://doi.org/10.1016/j.zemedi.2021.09.001.
Vergara Gomez, T.S., Dubois, M., Rustomji, K., Georget, E., Antonakakis, T., Vignaud, A., Rapacchi, S., Girard, O.M., Kober, F., Enoch, S. and Abdeddaim, R. (2022) “Hilbert fractal inspired dipoles for passive RF shimming in ultra-high field MRI,” Photonics and Nanostructures - Fundamentals and Applications, 48, p. 100988. Available at: https://doi.org/10.1016/j.photonics.2021.100988.
Jourdan, A., Rapacchi, S., Guye, M., Bendahan, D., Masson, C. and Bège, T. (2022) “Dynamic-MRI quantification of abdominal wall motion and deformation during breathing and muscular contraction,” Computer Methods and Programs in Biomedicine, 217, p. 106667. Available at: https://doi.org/10.1016/j.cmpb.2022.106667.
Daudé, P., Ancel, P., Confort Gouny, S., Jacquier, A., Kober, F., Dutour, A., Bernard, M., Gaborit, B. and Rapacchi, S. (2022) “Deep-Learning Segmentation of Epicardial Adipose Tissue Using Four-Chamber Cardiac Magnetic Resonance Imaging,” Diagnostics (Basel, Switzerland), 12(1), p. 126. Available at: https://doi.org/10.3390/diagnostics12010126.
Rapacchi, S., Viallon, M. and Croisille, P. (2022) “Editorial for ‘Impact of Temporal Resolution and Methods for Correction on Cardiovascular Magnetic Resonance Perfusion Quantification,’” Journal of Magnetic Resonance Imaging, 56(6), pp. 1720–1721. Available at: https://doi.org/10.1002/jmri.28402.
Brui, E.A., Rapacchi, S., Bendahan, D. and Andreychenko, A.E. (2021) “Comparative analysis of SINC-shaped and SLR pulses performance for contiguous multi-slice fast spin-echo imaging using metamaterial-based MRI,” Magnetic Resonance Materials in Physics, Biology and Medicine, 34(6), pp. 929–938. Available at: https://doi.org/10.1007/s10334-021-00937-w.
Sourdon, J., Roussel, T., Costes, C., Viout, P., Guye, M., Ranjeva, J.-P., Bernard, M., Kober, F. and Rapacchi, S. (2021) “Comparison of single-voxel 1H-cardiovascular magnetic resonance spectroscopy techniques for in vivo measurement of myocardial creatine and triglycerides at 3T,” Journal of Cardiovascular Magnetic Resonance: Official Journal of the Society for Cardiovascular Magnetic Resonance, 23(1), p. 53. Available at: https://doi.org/10.1186/s12968-021-00748-x.
Gaborit, B., Ancel, P., Abdullah, A.E., Maurice, F., Abdesselam, I., Calen, A., Soghomonian, A., Houssays, M., Varlet, I., Eisinger, M., Lasbleiz, A., Peiretti, F., Bornet, C.E., Lefur, Y., Pini, L., Rapacchi, S., Bernard, M., Resseguier, N., Darmon, P., Kober, F. and Dutour, A. (2021) “Effect of empagliflozin on ectopic fat stores and myocardial energetics in type 2 diabetes: the EMPACEF study,” Cardiovascular Diabetology, 20(1), p. 57. Available at: https://doi.org/10.1186/s12933-021-01237-2.
Foussier, C., Barral, P.A., Jerosh-Herold, M., Gariboldi, V., Rapacchi, S., Gallon, A., Bartoli, A., Bentatou, Z., Guye, M., Bernard, M. and Jacquier, A. (2021) “Quantification of diffuse myocardial fibrosis using CMR extracellular volume fraction and serum biomarkers of collagen turnover with histologic quantification as standard of reference,” Diagnostic and Interventional Imaging, 102(3), pp. 163–169. Available at: https://doi.org/10.1016/j.diii.2020.07.005.
Jourdan, A., Le Troter, A., Daude, P., Rapacchi, S., Masson, C., Bège, T. and Bendahan, D. (2021) “Semiautomatic quantification of abdominal wall muscles deformations based on dynamic MRI image registration,” NMR in Biomedicine, 34(4), p. e4470. Available at: https://doi.org/10.1002/nbm.4470.
Rapacchi, S. and Gaborit, B. (2021) “Editorial for ‘Association of Type 2 Diabetes Mellitus and Glycemic Control With Intracranial Plaque Characteristics in Patients With Acute Ischemic Stroke,’” Journal of Magnetic Resonance Imaging, 54(2), pp. 667–668. Available at: https://doi.org/10.1002/jmri.27739.
Hoesl, M.A.U., Schad, L.R. and Rapacchi, S. (2020) “Efficient 23 Na triple-quantum signal imaging on clinical scanners: Cartesian imaging of single and triple-quantum 23 Na (CRISTINA),” Magnetic Resonance in Medicine, 84(5), pp. 2412–2428. Available at: https://doi.org/10.1002/mrm.28284.
Lévy, S., Rapacchi, S., Massire, A., Troalen, T., Feiweier, T., Guye, M. and Callot, V. (2020) “Intravoxel Incoherent Motion at 7 Tesla to quantify human spinal cord perfusion: limitations and promises,” Magnetic Resonance in Medicine, 84(3), pp. 1198–1217. Available at: https://doi.org/10.1002/mrm.28195.
Habert, P., Capron, T., Hubert, S., Bentatou, Z., Bartoli, A., Tradi, F., Renard, S., Rapacchi, S., Guye, M., Bernard, M., Habib, G. and Jacquier, A. (2020) “Quantification of right ventricular extracellular volume in pulmonary hypertension using cardiac magnetic resonance imaging,” Diagnostic and Interventional Imaging, 101(5), pp. 311–320. Available at: https://doi.org/10.1016/j.diii.2019.12.008.
Bentatou, Z., Troalen, T., Bernard, M., Guye, M., Pini, L., Bartoli, A., Jacquier, A., Kober, F. and Rapacchi, S. (2020) “Simultaneous multi-slice T1 mapping using MOLLI with blipped CAIPIRINHA bSSFP,” Magnetic Resonance Imaging, pp. S0730-725X(19)30796–9. Available at: https://doi.org/10.1016/j.mri.2020.03.006.
Rapacchi, S., Troalen, T., Bentatou, Z., Quemeneur, M., Guye, M., Bernard, M., Jacquier, A. and Kober, F. (2019) “Simultaneous multi-slice cardiac cine with Fourier-encoded self-calibration at 7 Tesla,” Magnetic Resonance in Medicine, 81(4), pp. 2576–2587. Available at: https://doi.org/10.1002/mrm.27593.
Wei, W., Evin, M., Rapacchi, S., Kober, F., Bernard, M., Jacquier, A., Kahn, C.J.F. and Behr, M. (2019) “Investigating heartbeat-related in-plane motion and stress levels induced at the aortic root,” Biomedical Engineering Online, 18(1), p. 19. Available at: https://doi.org/10.1186/s12938-019-0632-7.
Trotier, A.J., Rapacchi, S., Faller, T.L., Miraux, S. and Ribot, E.J. (2019) “Compressed-Sensing MP2RAGE sequence: Application to the detection of brain metastases in mice at 7T,” Magnetic Resonance in Medicine, 81(1), pp. 551–559. Available at: https://doi.org/10.1002/mrm.27438.
Donadieu, M., Le Fur, Y., Maarouf, A., Gherib, S., Ridley, B., Pini, L., Rapacchi, S., Confort-Gouny, S., Guye, M., Schad, L.R., Maudsley, A.A., Pelletier, J., Audoin, B., Zaaraoui, W. and Ranjeva, J.-P. (2019) “Metabolic counterparts of sodium accumulation in multiple sclerosis: A whole brain 23Na-MRI and fast 1H-MRSI study,” Multiple Sclerosis (Houndmills, Basingstoke, England), 25(1), pp. 39–47. Available at: https://doi.org/10.1177/1352458517736146.
Bentatou, Z., Finas, M., Habert, P., Kober, F., Guye, M., Bricq, S., Lalande, A., Frandon, J., Dacher, J.N., Dubourg, B., Habib, G., Caudron, J., Normant, S., Rapacchi, S., Bernard, M. and Jacquier, A. (2018) “Distribution of left ventricular trabeculation across age and gender in 140 healthy Caucasian subjects on MR imaging,” Diagnostic and Interventional Imaging, 99(11), pp. 689–698. Available at: https://doi.org/10.1016/j.diii.2018.08.014.
Mchinda, S., Varma, G., Prevost, V.H., Le Troter, A., Rapacchi, S., Guye, M., Pelletier, J., Ranjeva, J.-P., Alsop, D.C., Duhamel, G. and Girard, O.M. (2018) “Whole brain inhomogeneous magnetization transfer (ihMT) imaging: Sensitivity enhancement within a steady-state gradient echo sequence,” Magnetic Resonance in Medicine, 79(5), pp. 2607–2619. Available at: https://doi.org/10.1002/mrm.26907.
Zhou, Z., Han, F., Yu, S., Yu, D., Rapacchi, S., Song, H.K., Wang, D.J.J., Hu, P. and Yan, L. (2018) “Accelerated noncontrast-enhanced 4-dimensional intracranial MR angiography using golden-angle stack-of-stars trajectory and compressed sensing with magnitude subtraction,” Magnetic Resonance in Medicine, 79(2), pp. 867–878. Available at: https://doi.org/10.1002/mrm.26747.
Habert, P., Bentatou, Z., Aldebert, P., Finas, M., Bartoli, A., Bal, L., Lalande, A., Rapacchi, S., Guye, M., Kober, F., Bernard, M. and Jacquier, A. (2018) “Exercise stress CMR reveals reduced aortic distensibility and impaired right-ventricular adaptation to exercise in patients with repaired tetralogy of Fallot,” PloS One, 13(12), p. e0208749. Available at: https://doi.org/10.1371/journal.pone.0208749.
Bydder, M., Rapacchi, S., Girard, O., Guye, M. and Ranjeva, J.-P. (2017) “Trimmed autocalibrating k-space estimation based on structured matrix completion,” Magnetic Resonance Imaging, 43, pp. 88–94. Available at: https://doi.org/10.1016/j.mri.2017.07.015.
Han, F., Rapacchi, S. and Hu, P. (2017) “Prospective cardiac motion self-gating,” Quantitative Imaging in Medicine and Surgery, 7(2), pp. 215–226. Available at: https://doi.org/10.21037/qims.2017.03.02.
Zhou, Z., Han, F., Rapacchi, S., Nguyen, K.-L., Brunengraber, D.Z., Kim, G.-H.J., Finn, J.P. and Hu, P. (2017) “Accelerated ferumoxytol-enhanced 4D multiphase, steady-state imaging with contrast enhancement (MUSIC) cardiovascular MRI: validation in pediatric congenital heart disease,” NMR in biomedicine, 30(1). Available at: https://doi.org/10.1002/nbm.3663.
Shao, J., Rapacchi, S., Nguyen, K.-L. and Hu, P. (2016) “Myocardial T1 mapping at 3.0 tesla using an inversion recovery spoiled gradient echo readout and bloch equation simulation with slice profile correction (BLESSPC) T1 estimation algorithm,” Journal of magnetic resonance imaging: JMRI, 43(2), pp. 414–425. Available at: https://doi.org/10.1002/jmri.24999.
Rashid, S., Rapacchi, S., Shivkumar, K., Plotnik, A., Finn, J.P. and Hu, P. (2016) “Modified wideband three-dimensional late gadolinium enhancement MRI for patients with implantable cardiac devices,” Magnetic Resonance in Medicine, 75(2), pp. 572–584. Available at: https://doi.org/10.1002/mrm.25601.
Skelton, R.J.P., Khoja, S., Almeida, S., Rapacchi, S., Han, F., Engel, J., Zhao, P., Hu, P., Stanley, E.G., Elefanty, A.G., Kwon, M., Elliott, D.A. and Ardehali, R. (2016) “Magnetic Resonance Imaging of Iron Oxide-Labeled Human Embryonic Stem Cell-Derived Cardiac Progenitors,” Stem Cells Translational Medicine, 5(1), pp. 67–74. Available at: https://doi.org/10.5966/sctm.2015-0077.
Rapacchi, S., Smith, R.X., Wang, Y., Yan, L., Sigalov, V., Krasileva, K.E., Karpouzas, G., Plotnik, A., Sayre, J., Hernandez, E., Verma, A., Burkly, L., Wisniacki, N., Torrington, J., He, X., Hu, P., Chiao, P.-C. and Wang, D.J.J. (2015) “Towards the identification of multi-parametric quantitative MRI biomarkers in lupus nephritis,” Magnetic Resonance Imaging, 33(9), pp. 1066–1074. Available at: https://doi.org/10.1016/j.mri.2015.06.019.
Han, F., Rapacchi, S., Khan, S., Ayad, I., Salusky, I., Gabriel, S., Plotnik, A., Finn, J.P. and Hu, P. (2015) “Four-dimensional, multiphase, steady-state imaging with contrast enhancement (MUSIC) in the heart: a feasibility study in children,” Magnetic Resonance in Medicine, 74(4), pp. 1042–1049. Available at: https://doi.org/10.1002/mrm.25491.
Han, F., Zhou, Z., Rapacchi, S., Nguyen, K.-L., Finn, J.P. and Hu, P. (2015) “Segmented golden ratio radial reordering with variable temporal resolution for dynamic cardiac MRI,” Magnetic Resonance in Medicine [Preprint]. Available at: https://doi.org/10.1002/mrm.25861.